Permit # | Issued | Address | Pin | Work | Expand |
---|---|---|---|---|---|
100310643 | 09/15/2009 | 1126 W 40TH ST | 20052000230000 | REPLACE EXISTING UNIT HEATERS WITH (20 INFRA RED HEATERS) | Expand |
100311965 | 12/11/2009 | 1126 W 40TH ST | 20052000230000 | INTERIOR BUILDOUT OF 5000 SF OFFICE WITH MEZZANINE ABOVE. ELECTRICAL, PLUMBING, HVAC, STRUCTURAL STEEL FRAMING | Expand |
100312489 | 10/28/2009 | 1126 W 40TH ST | 20052000230000 | INSTALL NEW ELECTRICAL SERVICES TO BUILDING ONE - 12470V 3PH 400 AND ONE - 480/277V 3PH 1200 AMP | Expand |
100321668 | 11/24/2009 | 1126 W 40TH ST | 20052000230000 | REVISION TO PERMIT # 100312489 TO CHANGE OWNER INFORMATION & EMERGENCY CONTACT. | Expand |
100326498 | 01/12/2010 | 1126 W 40TH ST | 20052000230000 | 1126 WEST 40TH STREET- OUC REVIEW ONLY; PIT CONSTRUCTION | Expand |
100338108 | 07/27/2010 | 1126 W 40TH ST | 20052000230000 | REVISION TO PERMIT # 100311965 ADD 2 OFFICES, RECONFIGURE MANS AND WOMENS BATHROOM AREA ADDING 1 URINAL AND 1 WC, DELETE 1 MOP SINK. IN THE SHOP BATHROOM DELETE 1 URINAL AND 2 WC ADD 1 LAV AND 1 ACCESSIBLE SHOWER.REVERSE THE DIRECTION OF RISE ON THE STAIRS. ADD IT CLOSET ON MEZZANINE. CHANGE WATER HEATER TO 2 POINT OF USE TANKLESS WATER HEATERS. RELOCATE COAT CLOSET. | Expand |
100355031 | 11/05/2010 | 1126 W 40TH ST | 20052000230000 | ERECT AN ATTACHED ADDITION TO AN EXISTING WAREHOUSE BUILDING. THIS IS A CONCRETE BLOCK SHED WITH A METAL ROOF THAT WILL ENCLOSE A 60,000 GALLON WATER TANK. LIGHTING, HEATING AND EXHAUST FANS ARE INCLUDED. | Expand |
100363338 | 11/24/2010 | 1126 W 40TH ST | 20052000230000 | CUT OPENINGS IN EXISTING EXTERIOR MASONRY WALL. INSTALL NEW STEEL LINTELS. INSTALL NEW THERMOPANE WINDOWS TO EXISTING INDUSTRIAL AND OFFICE | Expand |
100366895 | 12/08/2010 | 1126 W 40TH ST | 20052000230000 | HYDROAIRE LETTERS FACING 40TH ST. | Expand |
100744001 | 01/19/2018 | 1126 W 40TH ST | 20052000230000 | REPLACE ROOFTOP UNIT WITH SAE | Expand |
100744017 | 01/19/2018 | 1126 W 40TH ST | 20052000230000 | REPLACE ONE ROOFTOP UNIT WITH ONE, 7.5 TON, AIR COOLED, SELF-CONTAINED, R410A, CARRIER ROOFTOP UNIT, SERVING AN OFFICE SPACE. | Expand |
100867581 | 03/17/2021 | 1126 W 40TH ST | 20052000230000 | SPR 2019 CBC - INTERIOR ALTERATION WORK IN A MEZZANINE FLOOR ABOVE AN EXISTING OFFICE SPACE OF AN EXISTING SINGLE STORY INDUSTRIAL BUILDING. THE PROPOSED USE GROUP IS B-BUSINESS. RENOVATION OF MEZZANINE INTO A NEW 2ND FLOOR, 4,500 SQFT OFFICE SPACE, INCLUDES NEW OFFICES, BREAKROOM, TRAINING ROOM, TOILET ROOMS, EXIT STAIR AND LULA ELEVATOR AND MEP WORK AS PER PLANS.**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT ** | Expand |
100917071 | 07/23/2021 | 1126 W 40TH ST | 20052000230000 | REVISION TO PERMIT #100867581 USE GROUP B-BUSINESS. REVISED INTERIOR ALTERATION WORK IN THE 2ND FL, 4,500 SQFT SPACE INCLUDES REVISED CONFERENCE ROOM, TRAINING ROOM, COPY ROOM & CLOSET, REPLACED SERVER ROOM WITH OFFICE & ADDED WINDOW, INCREASED SIZE OF (2) OFFICES, REVISED FURNITURE LAYOUT, FINISHES, RCP & POWER/DATA, REVISED SOUTH WINDOWS & UPDATED NORTH STAIR LANDING & LULA TO PASSENGER ELEVATOR (UNDER SEPARATE PERMIT) WORK ALSO INCLUDES 1ST FLOOR, 155 SQFT ACCESSORY STORAGE ROOM & CORRESPONDING M.E.P. WORK PER PLANS **CERTIFIED PLANS CORRECTIONS: CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS ** | Expand |
100927814 | 07/15/2021 | 1126 W 40TH ST | 20052000230000 | INTERIOR ALTERATION WORK IN THE EXISTING 667 SQFT CONFERENCE ROOM WITHIN THE EXISTING OFFICE SPACE ON THE 1ST FLOOR. EXISTING OFFICE IS 2 FLOORS, APPROXIMATELY 4,500 SQFT EACH FLOOR AND IS WITHIN AN EXISTING SINGLE STORY F-1 INDUSTRIAL BUILDING. THE PROPOSED USE GROUP OF THE ALTERATION IS B-BUSINESS. RENOVATION WILL CONVERT EXISTING LARGE CONFERENCE ROOM INTO (2) SMALLER ACCESSORY ROOMS. THESE ROOMS WILL BE SEPARATED BY A NEW GLASS PARTITION. EXISTING RTU TO REMAIN. NEW DIFFUSER LOCATIONS. CORRESPONDING MECHANICAL & ELECTRICAL WORK ALSO INCLUDED. NOTE THAT THE BUILDING IS MIXED-USE WITH SEPARATED OCCUPANCIES AND THE REQUIRED FIRE SEPARATION BETWEEN THE OFFICE SPACE AND INDUSTRIAL SPACE IS ZERO HOURS.CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS) | Expand |
100942157 | 10/06/2021 | 1126 W 40TH ST | 20052000230000 | INSTALLATION OF (1) ONE MRL GEARLESS PASSENGER ELEVATOR PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION. | Expand |
B100321093 | 11/19/2009 | 1126 W 40TH ST | 20052000230000 | CHANGE OF ELECTRICAL CONTRACTOR TO KELSO-BURNETT FOR NOVAK PERMIT #100312489 | Expand |
B100325654 | 01/05/2010 | 1126 W 40TH ST | 20052000230000 | CHANGE ELECTRICAL CONTRACTOR FROM KELSO-BURNETT TO HUEN FOR PERMIT #100312489 | Expand |
B100356935 | 08/03/2010 | 1126 W 40TH ST | 20052000230000 | PROVIDE POWER WIRING AND CONNECTIONS FOR NEW MACHINES, FED FROM EXISTING SERVICE | Expand |