100132432 | 09/25/2006 | 3003 W TOUHY AVE | 10361000170000 | INTERIOR ALTERATIONS AND BUILDING UPGRADES PER PLANS | Expand |
100306058 | 08/14/2009 | 3003 W TOUHY AVE | 10361000170000 | TOTAL TEAR OFF | Expand |
100308555 | 09/03/2009 | 3003 W TOUHY AVE | 10361000170000 | REMOVE ONE 30 TON AHU & INSTALL FIVE (5) NEW RTUS WITH NEW SUPPLY & RETURN DUCT SYSTEM PER PLANS. | Expand |
100348473 | 06/10/2010 | 3003 W TOUHY AVE | 10361000170000 | REMOVE EVAPORATIVE COOLING TOWER WITH TWO CONDENSERS AND REPLACE WITH TWO NEW AIR COOLED CONDENSERS ON THE ROOF. | Expand |
100355454 | 07/26/2010 | 3003 W TOUHY AVE | 10361000170000 | REPLACE THE EXISTING AH-05 SNYDER GENERAL HVAC UNIT WITH ONE CARRIER 7.5 TON RTU. (SELF CONTAINED, AIR COOLED,R410A, LOCATED ON THE ROOF.) | Expand |
100390938 | 04/21/2011 | 3003 W TOUHY AVE | 10361000170000 | REMOVE TWO EXISTING 5 TON CARRIER RTU'S AND REPLACE WITH TWO NEW 5 TON CARRIER RTU'S, SELF CONTAINED, AIR COOLED, R410A, LOCATED ON THE ROOF. | Expand |
100399270 | 07/27/2011 | 3003 W TOUHY AVE | 10361000170000 | EXTERIOR RAMP, STAIR AND CONCRETE REPAIRS AS PER PLANS | Expand |
100409326 | 09/12/2011 | 3033 W TOUHY AVE | 10361000170000 | REMOVE ONE CARRIER 5 TON RTU FROM BERNARD HORWICH CENTER AND RELOCATE AT VIRGINIA FRANK CHILDRENS CENTER TO REPLACE UNIT VI. REPLACE THE EXISTING 8 1/2 TON RTU WITH A NEW CARRIER 7 1/2 TON TO REPLACE UNIT V5. THE UNITS ARE SELF CONTAINED, AIR COOLED, LOCATED ON THE ROOF. | Expand |
100410540 | 09/12/2011 | 3033 W TOUHY AVE | 10361000170000 | REPLACE 2 OF 5 EXISTING RTU'S WITH NEW CARRIER UNIT.( UNIT #'S V1 AND V2) | Expand |
100432425 | 03/20/2012 | 3003 W TOUHY AVE | 10361000170000 | INSTALL NEW GLASS BLOCK (7'-4" X 6' & 10' X 6' ) IN INTERIOR CORRIDOR ON THE 1ST FLOOR FOR EXISTING CLASSROOMS PER PLANS | Expand |
100513708 | 10/17/2013 | 3003 W TOUHY AVE | 10361000170000 | REMOVE THE EXISTING ROOFTOP UNIT H-9 AND REPLACE WITH THREE CARRIER 4 T0N ROOFTOP UNITS, SELF CONTAINED, AIR COOLED, R410A. THE ROOFTOP UNITS SERVE EXERCISE ROOMS. | Expand |
100513807 | 10/17/2013 | 3003 W TOUHY AVE | 10361000170000 | REMOVE (1) ROOF TOP UNIT AND REPLACE WITH 3 SMALLER UNITS. | Expand |
100609281 | 08/12/2015 | 3003 W TOUHY AVE | 10361000170000 | INSTALL ONE (1) 660LB,CAP, 12FPM, 3-STOP INCLINED PLATFORM LIFT. PURSUANT TO PLANS SUBMITTED. | Expand |
100643240 | 04/05/2016 | 3003 W TOUHY AVE | 10361000170000 | REPLACE 5 ROOF TOP UNITS | Expand |
100643256 | 04/05/2016 | 3003 W TOUHY AVE | 10361000170000 | REPLACEMENT OF FIVE (5) EXISTING RTU'S, WITH FIVE CARRIER ROOFTOP UNITS, SELF CONTAINED, AIR COOLED, R410A. THE ROOFTOP UNITS SERVE CLASSROOMS | Expand |
100661344 | 07/25/2016 | 3033 W TOUHY AVE | 10361000170000 | TEAR OFF AND REPLACE ROOF | Expand |
100663582 | 08/05/2016 | 3033 W TOUHY AVE | 10361000170000 | REPLACE WINDOWS THROUGHOUT. ALL WORK SAE | Expand |
101034571 | 02/16/2024 | 3003 W TOUHY AVE | 10361000170000 | SPR 2019 CBRC - INTERIOR ALTERATIONS TO LOWER LEVEL OFFICE AND TRAINING ROOMS. WORK TO INCLUDE NON-LOAD BEARING PARTITIONS, MODIFICATIONS TO MECHANICAL AND ELECTRICAL. NO PLUMBING WORK. NO CHANGE IN USE AS PER PLANS (B-BUSINESS OCCUPANCY; IB CONSTRUCTION)**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT ** | Expand |
101023918 | 10/23/2023 | 3003 W TOUHY AVE | 10361000170000 | DEMOLITION ONLY. INTERIOR DEMOLITION OF NON-LOAD BEARING PARTITIONS IN AN EXISTING COMMERCIAL OFFICE BUILDING ON THE 1ST FLOOR AND GARDEN LEVEL AS PER PLANS. WORK TO INCLUDE EXTERIOR DEMOLITION OF EXISTING CONCRETE PATIO, COLUMNS, AND ROOF. NO CHANGE IN USE (B-BUSINESS OCCUPANCY; IIB CONSTRUCTION)(CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS) | Expand |
101024682 | 08/16/2023 | 3003 W TOUHY AVE | 10361000170000 | INSTALL ONE 20-TON & ONE 10-TON ROOFTOP UNIT | Expand |
101027691 | 11/13/2023 | 3003 W TOUHY AVE | 10361000170000 | DDS: INTERIOR ALTERATIONS IN AN EXISTING COMMERCIAL OFFICE BUILDING ON THE 1ST FLOOR AS PER PLANS. WORK TO INCLUDE EXTERIOR CONSTRUCTION OF NEW CANOPY STRUCTURE, CONCRETE PATIOS AND RAMP. NO CHANGE IN USE (B-BUSINESS OCCUPANCY; IIB CONSTRUCTION) CONSULTANT REVIEWER: V3 COMPANIES OF IL | Expand |
B100141298 | 10/09/2006 | 3003 W TOUHY AVE | 10361000170000 | MISC LOW VOLTAGE TEMPERATURE CONTROLS | Expand |
B100150264 | 06/13/2007 | 3003 W TOUHY AVE | 10361000170000 | HARDWIRE (15) OFFICE MODULAR WORKSTATIONS WITH (2) RECEPTACLES PER STATION. CIRCUITS BY OTHERS! | Expand |
B100348334 | 06/14/2010 | 3003 W TOUHY AVE | 10361000170000 | PROVIDE 3 PHASE POWER FOR ( 2 ) CHILLER UNITS LOCATED ON ROOF. | Expand |
B100248954 | 07/24/2008 | 3003 W TOUHY AVE | 10361000170000 | ADT CONTRACTED TO INSTALL ACCESS CONTROL SYSTEM FOR CJE SENIOR LIFE ,ANNABELLE OMALLEY SALES REP | Expand |
B100514863 | 11/20/2013 | 3003 W TOUHY AVE | 10361000170000 | REUSE EXISTING 200 AMP POWER FEED , INSTALL NEW 200 AMP DISCONNECT SWITCH TO FEED (3) NEW 30 AMP FUSED DISCONNECTS FOR NEW ROOF TOP UNITS. | Expand |
B101004282 | 02/02/2023 | 3003 W TOUHY AVE | 10361000170000 | CJE SENIOR LIFE - 332-55016-21 - LOW VOLTAGE PERMIT FOR LOW VOLTAGE CARD ACCESS CONTROL INSTALLATION | Expand |
B101052427 | 06/28/2024 | 3003 W TOUHY AVE | 10361000170000 | **FIRE ALARM PERMIT**HEADEND PANEL REPLACEMENT OF AN EXISTING REQUIRED CLASS I FIRE ALARM SYSTEM PER CHICAGO BUILDING CODE. | Expand |
100954524 | 06/28/2022 | 3003 W TOUHY AVE | 10361000170000 | SPR 2019 CBRC: REPLACEMENT OF THE EXISTING PLAYGROUND (SURFACING AND EQUIPMENT), NEW ELEMENTS INCLUDE: OPEN SHELTER WITH LIGHT FIXTURES, ADDITIONAL PAVED TRAILS, LANDSCAPING, FENCE AND GATES INSIDE THE PROPERTY LINES. NO WORK ON THE EXISTING BUILDING, NO CHANGE IN OCCUPANCY. | Expand |
B200016915 | 05/15/2024 | 3003 W TOUHY AVE | 10361000170000 | FOUR POLE INSTALLATION FOR CHALLENGE COURSE PER STRUCTURLA ENGINEER'S CALCULATION AND PLAN. LOCATIONS: 0 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), EXTERIOR WORK, IN A PLAYGROUND FIELD. PLEASE HAVE DRAWINGS AND CALCULATIONS ONSITE DURING CONSTRUCTION AND INSPECTION | Expand |