Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 12:32 PM
PIN: 16261170360000
Property Address: 2406 S CENTRAL PARK AVE
City - Zip: CHICAGO - 60623
2023 Property Class: EX
2023 Township: 77 - West Chicago
2023 Neighborhood: 77115
2023 Tax District: 77079
Cook Viewer GIS: External GIS Website
Chicago Building Permits Data: 6 Permits
Permit # Issued Address Pin Work Expand
100497142 06/26/2013 2406 S CENTRAL PARK AVE 16261170360000 CPS ALTERATIONS AND RENOVATIONS Expand
100696591 05/12/2017 2406 S CENTRAL PARK AVE 16261170360000 NO DWELLING UNITS, 2 STORIES, EDUCATIONAL USE,ROOF REPLACEMENT (MODIFIED BITUMEN ROOFING SYSTEM), INTERIOR WALL AND CEILING REPAIRS, MEP EQUIPMENT REPLACEMENT, WINDOW GASKET REPLACEMENT, AND MASONRY RESTORATION, INCLUDING BRICK REPLACEMENT, TUCKPOINTING, AND STONE / CONCRETE CRACK REPAIR. Expand
100765362 06/21/2018 2406 S CENTRAL PARK AVE 16261170360000 CPS SCHOOL. NO CHANGE IN USE. REMOVAL OF DEMISING WALL BETWEEN TWO CLASSROOMS TO CREATE ONE LARGER CLASSROOM. REPLACEMENT OF FINISHED FLOOR, PAINTING, NEW ELECTRICAL OUTLETS. Expand
100964666 10/28/2022 2406 S CENTRAL PARK AVE 16261170360000 SPR 2019 CBRC: REPLACE EXISTING PLAYGROUND, PARTIAL FENCE (LESS THAN 4FT IN LENGTH) AND PAVEMENT AT CPS CARDENAS MODULAR SCHOOL. EXTERIOR IMPROVEMENTS ONLY, NO INTERIOR SCOPE OF WORK. OCCUPANCY GROUP E-1 (TO REMAIN), TYPE II-A CONSTRUCTION (TO REMAIN). Expand
B100475636 01/28/2013 2406 S CENTRAL PARK AVE 16261170360000 AND ATTACHED ADDRESS LIST - RETROFIT OF EXISTING LIGHT FIXTURES WITH T12 FLUORESCENT LAMPS AND ELECTROMAGNETIC BALLASTS WITH T8 LAMPS AND ELECTRONIC BALLASTS. RETROFIT OF EXISTING EXIT SIGNS WITH LED RETROFIT KITS. WIRELESS OCCUPANCY SENSORS AND WIRELESS RECEIVER SWITCHES FOR LIGHTING CONTROL AT CLASSROOMS ONLY. ALL WORK SHALL UTILIZE EXISTING ELECTRICAL CIRCUITS AND WIRING. Expand
B100718030 08/11/2017 2406 S CENTRAL PARK AVE 16261170360000 INSTALL MICROPHONE ON BUILDING. TAPPING INTO EXISTING 110 VOLTS. INSTALLING LOW VOLTAGE WIRE. INSTALLING 110V AC IN CONDUIT TO POWER SUPPLY. EXTEND LOW VOLTAGE FROM POWER SUPPLY TO MICROPHONE SENSOR. THIS IS A NO FEE PERMIT PER CITY ORDINANCE, NO FEE WAIVER. Expand