Permit # | Issued | Address | Pin | Work | Expand |
---|---|---|---|---|---|
100316961 | 01/15/2010 | 5555 W HENDERSON ST | 13213190020000 | ATTIC AND BASEMENT DECONVERSION TO ORIGINAL USE AS INACTIVE STORAGE,(BUILDING DECONVERSION FROM 3 DWELLING UNITS TO SINGLE FAMILY RESIDENCE AS PER PLANS). | Expand |
B100907048 | 01/27/2021 | 5555 W HENDERSON ST | 13213190020000 | SCOPE CHECK TO SEE IF THE WINDOW NEAR THE MAST IS ABLE TO BE OPENED. IF IT CAN OPEN THE MAST WILL NEED TO BE EXTENDED ABOVE THE ROOF. SURVEY DID NOT INCLUDE A VIEW OF THE ROOM THAT THE PANEL IS LOCATED IN. VERIFY IT IS IN A CODE COMPLIANT LOCATION. UNABLE TO TELL THE DISTANCE FROM THE MSP TO THE SERVICE ENTRANCE. IF IT IS GREATER THAN 5 FEET THEN A DISCONNECT WILL NEED TO BE INSTALLED INSIDE THE HOME ON THE SAME INTERIOR WALL THAT THE METER IS ON. REPLACE MAIN SERVICE PANEL WITH A 125/100A PANEL MINIMUM 30 BREAKER SLOTS AHJ: 2018 CHICAGO ELECTRICAL CODE GOVERNING ELECTRICAL CODE: COOK COUNTY CHECK AND FOLLOW AHJ AMENDMENTS PRIOR TO PERMIT ENSURE BONDING AND GROUNDING ARE UP TO CODE. BOND THE COLD WATER MAIN. BOND STREET SIDE FIRST | Expand |