Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 1:23 PM
PIN: 20064210380000
Property Address: 1824 W 47TH ST
City - Zip: CHICAGO - 60609
2023 Property Class: 212
2023 Township: 72 - Lake
2023 Neighborhood: 72080
2023 Tax District: 72095
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 55 Violations
Violation Inspector Comments Address Category Status View
REPAIR WINDOW SILLS SOUTH ELEVATION 2ND FLOOR - OPEN SILL JOINTS 1824 W 47TH ST PERIODIC FAILED View
PARAPET SOUTHWEST CORNER PARAPET - WASHED OUT MORTAR AND OPEN JOINTS. 1824 W 47TH ST PERIODIC FAILED View
REPAIR EXTERIOR WALL WEST ELEVATION ABOVE 2ND FLOOR - STEP CRACKING AND SHIFTING BRICKS EXTENDING FROM CORNERS OF WINDOWS. *PLANS AND PERMIT REQUIRED FOR REPAIRS. 1824 W 47TH ST PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS WEST ELEVATION 1ST FLOOR - CRACKED AND BROKEN GLASS BLOCK WINDOWS. 1824 W 47TH ST PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED 1ST FLOOR DOCTORS OFFICE LOBBY - EXIT SIGN NOT ILLUMINATED. 1824 W 47TH ST PERIODIC FAILED View
REPAIR INTERIOR WALLS/CEILING 1ST FLOOR DOCTORS OFFICE LOBBY - CEILING TILE STAINED. 1824 W 47TH ST PERIODIC FAILED View
ARRANGE FOR REINSPECTION REGAR INTERIOR 2ND FLOOR DWELLING UNITS - NO ENTRY - UNVERIFIED DETECTORS, EGRESS AND CONDITIONS. 1824 W 47TH ST PERIODIC FAILED View
REPAIR LINTELS WEST ELEVATION 2ND FLOOR WINDOWS - LINTELS SAGGING, RUSTED AND EXPANDING. *PLANS AND PERMIT REQUIRED FOR REPAIRS. 1824 W 47TH ST PERIODIC FAILED View
REPAIR DOOR HARDWARE 2ND FLOOR FRONT ENTRY DOOR MISSING DOOR CLOSURE. 1824 W 47TH ST COMPLAINT FAILED View
PROVIDE ADEQUATE SUPPORT BASEMENT - INSTALL APPROVED HANGERS ON THE 2" COPPER WASTE LINE. 1824 W 47TH ST COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) OBTAIN A STRUCTURAL ENGINEER'S REPORT FOR CONDITIONS OBSERVED IN THE BASEMENT. 1). 6X6 BEAMS INSTALLED WITH SHORING POST IN AREAS OF THE BASEMENT. 2). JOISTS WITH TERMITE DAMAGE IN THE BASEMENT. 3). SCORCHED JOIST DUE TO FIRE DAMAGE. 1824 W 47TH ST COMPLAINT FAILED View
STRUCTURAL MEMBER, PIER BLOCK REPAIR/REPLACE DEFECTIVE STRUCTURAL MEMBERS ACCORDING TO STRUCTURAL ENGINEER'S REPORT FOR BASEMENT AREA. 1824 W 47TH ST COMPLAINT FAILED View
MIXED OCCUPANCY SEPARATION OPEN JOIST BASEMENT, 1ST FLOOR AND REAR 2ND FLOOR AREAS. 1824 W 47TH ST COMPLAINT FAILED View
1-HR HEATING PLANT ENCLOSURE NO HEATING PLANT ENCLOSURE IN THE BASEMENT, DOOR IN FURNACE ROOM 2ND FLOOR FRONT BROKEN. 1824 W 47TH ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING CEILING TILE 1ST AND 2ND FLOOR WATER DAMAGED. 1824 W 47TH ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS 2ND FLOOR AND SMOKE DETECTOR IN BASEMENT NOT WORKING, NO SMOKE DETECTORS IN BEDROOMS. 1824 W 47TH ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTORS 1ST FLOOR, 2ND FLOOR AND BASEMENT. 1824 W 47TH ST COMPLAINT FAILED View
UNINTERRUPTED EXIT AT GRADE 2ND FLOOR FRONT APARTMENT REAR EXIT OBSTRUCTED WITH DEBRIS AND LEAD THROUGH 2ND FLOOR REAR APARTMENT. 1824 W 47TH ST COMPLAINT FAILED View
DWELLING CLEAN AND SANITARY 2ND FLOOR FRONT APARTMENT CLOTHES AND DRUG NEEDLES ALL OVER. 1824 W 47TH ST COMPLAINT FAILED View
STOP/REMOVE NUISANCE CAR TIRES STORED IN 2ND FLOOR FURNACE ROOM CAUSING DANGEROUS AND HAZARDOUS CONDITIONS. 1824 W 47TH ST COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL NO FIRE EXTINGUISHERS OBSERVED 2ND FLOOR. 1824 W 47TH ST COMPLAINT FAILED View
PRV CNTRL VALVE WATER SUPPLY BASEMENT - REPLACE 3/4" GLOBE VALVE TO THE WATER HEATER WITH A FULL OPEN VALVE. 1824 W 47TH ST COMPLAINT FAILED View
PLANS & PERMITS REQUIRED 2ND FLOOR REAR BUILD OUT FOR COMMERCIAL USE NOW BEING USED AS A DWELLING UNIT. 1824 W 47TH ST COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL REPLACE 2" WASTE PIPE AT THE WEST SIDE OF BASEMENT, LINE IS RUN WITH 2" DWV COPPER PIPE, REPLACE WITH APPROVED MATERIAL. 1824 W 47TH ST COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING REPLACE THE 1-1/2" PVC PIPE AND FITTINGS USED ON THE WASTE LINES IN BASEMENT AND THE DISCHARGE LINE ON THE SUMP PUMP WITH APPROVED MATERIALS. 1824 W 47TH ST COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE 1ST FLOOR - REPIPE THE SUPPLY TUBES TO THE FIXTURES IN THE (2) BATHROOMS ON THE NORTHEAST END OF THE BUILDING WITH COPPER SUPPLIES. 1824 W 47TH ST COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE 2ND FLOOR FRONT UNIT - REPLACE FLEX WATER TO KITCHEN SINK, LAVATORY AND TOILET WITH COPPER SUPPLIES. 1824 W 47TH ST COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL 2ND FLOOR FRONT UNIT - REPLACE SHOWER WASTE PIPE WITH APPROVED MATERIALS. 1824 W 47TH ST COMPLAINT FAILED View
INSTALL INDIRECT SANT. WASTE 2ND FLOOR REAR UNIT - INSTALL AN OPEN SITE WASTE FOR SAFE PAN AND RELIEF VALVE FOR WATER HEATER. 1824 W 47TH ST COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC HIRE A LICENSED PLUMBING CONTRACTOR TO CORRECT ALL PLUMBING VIOLATIONS. 1824 W 47TH ST COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK PULL A PLUMBING PERMIT TO CORRECT ALL PLUMBING VIOLATIONS. 1824 W 47TH ST COMPLAINT FAILED View
NO PERMIT WIRING FOR THE INSTALLATION AND ALTERATION OF BUILDING PREMISE WIRING SYSTEM, ADDITIONAL PANELS, WIRING AND DEVICES, CONVERSION OF 2ND FLOOR TO A DWELLING UNIT. 1824 W 47TH ST COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY 3 METER SERVICE CURRENTLY FEEDS 1ST FLOOR COMMERCIAL SPACE AND 2-2ND FLOOR DWELLING UNITS. PROVIDE SEPARATE PANEL AND METERING TO SERVE BUILDING COMMON AREA LOADS. (18-27-210.25) 1824 W 47TH ST COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION BOND NEUTRAL AT SERVICE DISCONNECTS. (18-27-250.28) MAIN SERVICE DISCONNECTS IN PANELS MUST BE BOLT ON TYPE. (18-27-384.16) CONDUCTOR (NEUTRAL) SPLIT TO TERMINATE ON BUS BAR. PROVIDE LUG TO PROPERLY TERMINATE. (18-27-110.3) 1824 W 47TH ST COMPLAINT FAILED View
DEFECTIVE FIXTURES BASEMENT, 2ND FLOOR FRONT - BROKEN, NON-WORKING, MISSING COVERS/GLOBES. 1824 W 47TH ST COMPLAINT FAILED View
INSTALL COVERS BASEMENT, 1ST FLOOR AREA ABOVE DROP CEILING. (DANGEROUS AND HAZARDOUS) 1824 W 47TH ST COMPLAINT FAILED View
ARMORED CABLE 1ST FLOOR ABOVE DROP CEILING EXPOSED RUNS, WHIPS IN EXCESS OF 6 FT. AT SERVICE DISCONNECTS FROM PANELS TO SWITCHES - EXPOSED RUNS. IN BASEMENT EXPOSED RUNS. 1824 W 47TH ST COMPLAINT FAILED View
PROPER SIZE GRD ELECTRODE COND GROUND SERVICE AT ALL SERVICE DISCONNECTS. (18-27-250.50) PROVIDE GROUNDING CONDUCTOR TERMINATED AT WATER ENTRY 5 FOOT RULE - NO GROUND PRESENT. (DANGEROUS AND HAZARDOUS) 1824 W 47TH ST COMPLAINT FAILED View
SYSTEM II PROVIDE PROPER EMERGENCY LIGHTING. BATTERY BACK-UP REQUIRED FOR ALL EXIT AND EMERGENCY LIGHTING. (18-27-700.6) PROPERLY CIRCUIT, IDENTIFY AND LOCK-OUT ALL EXIT AND EMERGENCY LIGHTING CIRCUITRY. (18-27-700.66) THERE IS CURRENTLY INADEQUATE EM LIGHTING AND NON-BATTERY BACK-UP EXIT SIGNS. THE 2ND FLOOR IF COMMERCIAL SPACE REQUIRES BOTH EM AND EXIT SYSTEM INSTALLATION. 1824 W 47TH ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE GFCI PROTECTION FOR 2ND FLOOR KITCHENS AND BATHROOMS. (18-27-570.8) 1824 W 47TH ST COMPLAINT FAILED View
CORD TO FIXTURE 2ND FLOOR ABOVE DROP CEILING. 1824 W 47TH ST COMPLAINT FAILED View
REMOVE RECEPTACLES FROM ABOVE DROP CEILINGS 2ND FLOOR. READILY ACCESSIBLE ISSUE FOR DISCONNECTING MEANS. (18-27-110.3) 1824 W 47TH ST COMPLAINT FAILED View
DEFECTIVE FEEDER DISTRIBUTION FROM SERVICE DISCONNECTS - FEEDERS TO BASEMENT PANELS ARE ILLEGALLY DERIVED AND LACK PROPER OVERCURRENT PROTECTION. (18-27-240.21) TAP RULES 1824 W 47TH ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS 1824 W 47TH ST PERMIT FAILED View
REPAIR LINTELS WEST ELEVATION 2ND FLOOR WINDOWS - LINTELS SAGGING, RUSTED AND EXPANDING. *PLANS AND PERMIT REQUIRED FOR REPAIRS. 1824 W 47TH ST PERIODIC FAILED View
ARRANGE COMPLETED PERMIT INSP. 1824 W 47TH ST PERMIT PASSED View
OPEN 1824 W 47TH ST PERMIT FAILED View
OPEN 1824 W 47TH ST PERMIT PASSED View
EXPOSED WIRING FIXTURES BASEMENT (DANGEROUS AND HAZARDOUS) 1824 W 47TH ST COMPLAINT FAILED View
GROUNDING RECEPTACLES 2ND FLOOR FRONT 1824 W 47TH ST COMPLAINT FAILED View
OPEN BASEMENT - INSTALL WASTE LINE WITH PROPER PITCH. (18-29-704.1) 1824 W 47TH ST COMPLAINT FAILED View
INSTALL FIXTURES PROPER MATERL 2ND FLOOR REAR UNIT - INSTALL SAFE PAN UNDER THE WATER HEATER. 1824 W 47TH ST COMPLAINT FAILED View
REPAIR DOOR, INT. MISSING DOORS 2ND FLOOR FRONT AT BEDROOMS. 1824 W 47TH ST COMPLAINT FAILED View
PROVIDE NO EXIT DIAGRAMS POSTED 2ND FLOOR. (15-4-881) 1824 W 47TH ST COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING 2ND FLOOR FRONT UNIT - REPLACE THE PLASTIC WASTE PIPE AND TRAPS UNDER THE KITCHEN SINK AND LAVATORY. 1824 W 47TH ST COMPLAINT FAILED View