Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE FOR INSPECTION | CONTACT INSPECTOR ROBINSON #983 @ 312 743 3562 ON THURSDAYS FROM 700-800AM | 8222 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO BASEMENT AREAS AND ELECTRICAL ROOM. | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE AND VANDALIZED AND UNDERSIZED 200 AMP SERVICE. INSTALL MINIMUM 400 AMP SERVICE. DANGEROUS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES WITH EXPOSED WIRING IN WALK-IN COOLER. IMPROPER FIXTURES INSTALLED FOR WET LOCATIONS. ALL EQUIPMENT MUST BE WEATHERPROOF. DANGEROUS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SUPPORT ALL CONDUITS AND JUNCTION BOXES THROUGHOUT THE BASEMENT AND SUPPORT ALL LIGHT FIXTURES THROUGHOUT ALL STORE CEILING AREAS | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | FIXTURE WHIPS ARE NOT CONNECTED TO FIXTURE THROUGHOUT STORE | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | EXPOSED WIRING AT FIXTURES THROUGHOUT CEILING OF STORE DANGEROUS AND HAZARDOUS | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | INSTALL COVERS ON 1900 BOXES THROUGHOUT CEILING OF STORE DANGEROUS AND HAZARDOUS | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | INSTALL FACTORY COVER FOR LIGHT FIXTURE IN WALK-IN COOLER 18-27-110.3B | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
NO PERMIT WIRING | PROVIDE PERMIT FOR WORK BEING DONE WITHOUT PERMIT | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAY | PROVIDE CONTINUITY FOR ALL RACEWAYS IN CEILING DANGEROUS AND HAZARDOUS | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
CLOSE BOX OPENINGS | CLOSE OPENING IN SERVICE PANELS IN STORE | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | OPEN EXPOSED WIRING THROUGHOUT CEILING OF STORE DANGEROUS AND HAZARDOUS | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
PROVIDE | (15-8-220) BOTH FURNACES AT 1ST FLOOR STORE LACK THE REQUIRED ENCLOSURES. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO 2ND FLOOR UNIT. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | STEEL PICKET FENCE OVER 5 FT. REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | WEST MARKED EXIT DOORS REDUCED TO 32" AND 34". UNDER THE REQUIRED 36" THAT ALL MARKED EXIT DOORS ARE REQUIRED TO BE. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
PROVIDE | PATH LEADING TO WEST MARKED EXIT REDUCED TO 22" FROM TABLE TO KNEE WALL. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. (15-4-880, 15-4-900) | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
PROVIDE | THERE IS A BREACH IN FIRE SEPARATION ABOVE DROP CEILING FROM COMMERCIAL SPACE TO RESIDENTIAL SPACE ABOVE, SECTIONS OF DRYWALL BROKEN AND MISSING. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. (13-56-280) | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
PROVIDE | ELEVATED WOOD PLATFORM REQUIRES PROPER FIRE BLOCKING. (15-8-570) | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
REMOVE | 1ST/BASEMENT HAS STORED PRESSURE WASHER, GAS LAWN MOWERS. (15-4-090) | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
FIRE EXTNGSHR REQ, RESDNTL | FIRE EXTINGUISHERS NOT MOUNTED TO WALL. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | NON-LOAD BEARING PARTITION WALLS WERE CONSTRUCTED WITHOUT PROPER PLANS/PERMITS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
DWELLING CLEAN AND SANITARY | BASEMENT WALLS HAVE BLACK MOLD ON WALLS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | PROPER PLANS AND OR PERMITS ARE REQUIRED FOR ALL REPAIRS OR REPLACEMENT OF WORK NEEDED TO BRING BUILDING UP TO CHICAGO CODE. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
SEAL DRAIN OPENING UNUSD FIXTR | BASEMENT HAS OPEN SEWERS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
PROVIDE | BASEMENT STAIRWELL CEILING COVERED IN PLYWOOD MISSING PROPER FIRE SEPARATION TO COMMERCIAL SPACE AND RESIDENTIAL STAIRWELL. BASEMENT DOOR IS NOT A ONE HOUR FIRE RATED DOOR. BASEMENT CEILING HAS A BREACH IN THE FIRE SEPARATION. THERE ARE PIPES GOING THROUGH CONCRETE FLOOR THAT IS FILLED IN AROUND PIPES WITH SPRAY FOAM. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. 6(13-60-200) | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
SYSTEM III | INSTALL EMERGENCY LIGHTING SYSTEM III. NEED TO INSTALL ADDITIONAL EMERGENCY LIGHTS AND ADDITIONAL EXIT SIGNS. DANGEROUS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | REMOVE ALL UNAPPROVED EXTENSION CORDS AND POWER STRIPS. INSTALL ADDITIONAL RECEPTACLES TO AVOID USE OF CORDS. DANGEROUS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
SEPARATION OF DWELLING | MISSING SECTIONS OF FIRE SEPARATION IN FIRST FLOOR COMMERCIAL SPACE TO SECOND FLOOR DWELLING UNITS D & H | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED | WALLS FRAMED AND DRYWALLED IN THE BASEMENT AREA AND NORTHWEST SECTION OF COMMERCIAL SPACE | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
RMV PLBFIX INSTALLD W/0 PERMIT | REMOVE ALL PLUMBING INSTALLED WITHOUT A PERMIT ON THE BASEMENT AND 1ST FLOOR | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
SUBMIT PLANS FOR PLUMBING PRMT | SUBMIT PLANS FOR REVIEW AND PERMIT | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
ENGAG LIC & BOND PLMBNG CNTRC | LICENSED PLUMBING CONTRACTOR | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
REMOVE ALL ABANDON RACEWAY, JUNCTION BOXES, AND ELECTRICAL EQUIPMENT THROUGHOUT THE BASEMENT AND FIRST FLOOR STORE AREA 14E-1-110.12 | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View | |
INSTALLATION OF ELECTRICAL CONDUIT, BOXES, WIRING, DEVICES, AND ELECTRICAL EQUIPMENT INSTALLED THROUGHOUT THE FIRST FLOOR STORE AREA AND BASEMENT WITHOUT ROUGH INSPECTION REQUIRES ALL WALLS AND CEILING TO BE OPENED 13-12-380 | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View | |
NO PERMIT WIRING | OBTAIN AN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT THE ELECTRICAL VIOLATIONS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | STEEL PICKET FENCE OVER 5 FT. REDUCE HEIGHT, REMOVE OR OBTAIN A PERMIT. | 8222 S COTTAGE GROVE AVE | COMPLAINT | PASSED | View |
ACCESS TO ROOF | A/C UNDER 5 TONS | 8222 S COTTAGE GROVE AVE | PERIODIC | FAILED | View |
ADD RECEPTACLES | ADD OUTLETS TO ELIMINATE EXTENSION CORDS | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View | |
(18-27-400.8) REMOVE ALL CORD CONNECTIONS TO LIGHT FIXTURES ON EXTERIOR OF BUILDING AT PARKING LOT SIDE OF BUILDING AND REAR OF BUILDING - DANGEROUS. | 8222 S COTTAGE GROVE AVE | COMPLAINT | FAILED | View |