The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
STOP/REMOVE NUISANCE | ABANDONED VEHICLE IN REAR YARD; BROKEN APPARATUS STORED UNDERNEATH REAR PORCH | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL MISSING AT PARKING PAD; 22 3/4" DROP | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 COLUMN OUT OF PLUMB,OVERNOTCHED, AND SPLITTING (GRADE); 6X6 COLUMNS TOENAILED AND PULLLING AWAY FROM 6X6 BEAMS AT 1ST FLOOR; 6X6 BEAMS AT 2ND FL (NW CORNER) OVERNOTCHED INTO RECESS OF EXTERIOR WALL; 2X6 JOISTS SPAN 11'-0"; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; 12" SPLICE JOINT AT 2ND FLOOR SEPARATING, 3/4" GAP; RAIL HEIGHT ONLY 36 1/2"; HANDRAIL HEIGHT ONLY 28 1/2"; SPINDLES ON OUTSIDE ASPECT; SPINDLES MISSING FROM GRADE TO 3RD FLOOR; LOOSE RAILS AND HANDRAILS THRU-OUT; OPEN RISER DESIGN; DIFFERENT RISER HEIGHTS AND TREAD WIDTHS (2ND TO 3RD); TREADS LOOSE, WEAK, ROTTING, AND CUPPING THRU-OUT; PAINT PEELING THRU-OUT. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | NORTH - HANDRAIL MISSING FROM GRADE TO BASEMENT LEVEL;EAST - FRONT STAIRS - FOUNDATION STATUS UNKNOWN; HANDRAILS MISSING - FALL HAZARD; SPINDLES MISSING AT RAILS; RAIL HEIGHT ONLY 27 1/2". | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | TRASH, DEBRIS THRU-OUT FRONT YARD. | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
PARAPET | PARAPET WALL - LEANING INWARD. PERMIT REQUIRED TO REPAIR PARAPET WALL. | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
NO CLOSET/STORAGE UNDER STAIR | BROKEN APPARATUS STORED UNDERNEATH REAR PORCH. | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
CHIMNEY | CHIMNEY - WASHED OUT MORTAR | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | WINDOW FRAMES - ROTTING | 1816 S FAIRFIELD AVE | COMPLAINT | PASSED | View |