Last Modification Date: 2024-10-23 @ 9:42 AM
PIN: 16244070260000
Property Address: 1816 S FAIRFIELD AVE
City - Zip: CHICAGO - 60608
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77030
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 10 Violations
Violation Inspector Comments Address Category Status View
STOP/REMOVE NUISANCE ABANDONED VEHICLE IN REAR YARD; BROKEN APPARATUS STORED UNDERNEATH REAR PORCH 1816 S FAIRFIELD AVE COMPLAINT PASSED View
PROVIDE GUARD RAIL 42 IN HIGH GUARDRAIL MISSING AT PARKING PAD; 22 3/4" DROP 1816 S FAIRFIELD AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR PORCH - FOUNDATION STATUS UNKNOWN; 6X6 COLUMN OUT OF PLUMB,OVERNOTCHED, AND SPLITTING (GRADE); 6X6 COLUMNS TOENAILED AND PULLLING AWAY FROM 6X6 BEAMS AT 1ST FLOOR; 6X6 BEAMS AT 2ND FL (NW CORNER) OVERNOTCHED INTO RECESS OF EXTERIOR WALL; 2X6 JOISTS SPAN 11'-0"; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; 12" SPLICE JOINT AT 2ND FLOOR SEPARATING, 3/4" GAP; RAIL HEIGHT ONLY 36 1/2"; HANDRAIL HEIGHT ONLY 28 1/2"; SPINDLES ON OUTSIDE ASPECT; SPINDLES MISSING FROM GRADE TO 3RD FLOOR; LOOSE RAILS AND HANDRAILS THRU-OUT; OPEN RISER DESIGN; DIFFERENT RISER HEIGHTS AND TREAD WIDTHS (2ND TO 3RD); TREADS LOOSE, WEAK, ROTTING, AND CUPPING THRU-OUT; PAINT PEELING THRU-OUT. PLANS AND PERMIT REQUIRED TO REPAIR REAR PORCH. 1816 S FAIRFIELD AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR NORTH - HANDRAIL MISSING FROM GRADE TO BASEMENT LEVEL;EAST - FRONT STAIRS - FOUNDATION STATUS UNKNOWN; HANDRAILS MISSING - FALL HAZARD; SPINDLES MISSING AT RAILS; RAIL HEIGHT ONLY 27 1/2". 1816 S FAIRFIELD AVE COMPLAINT PASSED View
DEBRIS, EXCESSIVE TRASH, DEBRIS THRU-OUT FRONT YARD. 1816 S FAIRFIELD AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. 1816 S FAIRFIELD AVE COMPLAINT PASSED View
PARAPET PARAPET WALL - LEANING INWARD. PERMIT REQUIRED TO REPAIR PARAPET WALL. 1816 S FAIRFIELD AVE COMPLAINT PASSED View
NO CLOSET/STORAGE UNDER STAIR BROKEN APPARATUS STORED UNDERNEATH REAR PORCH. 1816 S FAIRFIELD AVE COMPLAINT PASSED View
CHIMNEY CHIMNEY - WASHED OUT MORTAR 1816 S FAIRFIELD AVE COMPLAINT PASSED View
MAINTAIN WINDOW WINDOW FRAMES - ROTTING 1816 S FAIRFIELD AVE COMPLAINT PASSED View