Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | SR#801572941-BUILDING/OWNERS I.D SIGN MISSING. | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT EXTERIOR PORCH/ENTIRE STRUCTURE SAGGING. DECKING ROTTING AND SAGGING. STRINGERS-LOOSE AND SAGGING. DECK JOISTS-SAGGING RAILING SECTIONS-LOOSE, PULLING, ROTTING, WITH PICKETS MISSING. REAR EXTERIOR PORCH/COLUMNS-ROTTING AT 2ND FLOOR. UNDERSIZED 4X6 BEAM SPANS 6 FEET. BEAM TO COLUMN CONNECTION ROTTING AND SCABBED 1-COLUMN MISSING AT 2ND FLOOR DECK. RAILING SECTIONS-LOOSE, PULLING, AND ONLY 35 INCHES HIGH. STRINGER AT 2ND FLOOR SEPARATING FROM DECK. ENTIRE SECTION OF ENCLOSED 2ND FLOOR PORCH APPEARS TO BE SAGGING. PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF FRONT AND REAR EXTERIOR PORCHES. | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
INT WALL/CEILING PEELING PAINT | BASEMENT APARTMENT/WALLS AND BASEBOARD-MILDEW BULGED. | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR HARDWARE | BASEMENT APARTMENT/ENTRY DOOR-DOORKNOB AND LOCK SET MISSING. | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR HALLWAY AND BASEMENT APARTMENT/SMOKE DETECTORS-MISSING. | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | BASEMENT APARTMENT/CARBON MONOXIDE DETECTOR-MISSING. | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
EGRESS -BASEMENT | BASEMENT DWELLING UNIT-ONLY ONE EGRESS EXISTS (IN THE REAR). | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT APARTMENT/CEILING HEIGHT-6"-2" HIGH. | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |
INT WALL/CEILING CHIP PLASTER | BASEMENT APARTMENT/WALLS-BROKEN SECTIONS OR DRYWALL | 4244 W THOMAS ST | COMPLAINT | CLOSED | View |