Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-26 @ 2:08 AM
PIN: 13132320150000
Property Address: 2501 W SUNNYSIDE AVE
City - Zip: CHICAGO - 60625
2023 Property Class: 315
2023 Township: 71 - Jefferson
2023 Neighborhood: 71110
2023 Tax District: 71001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 16 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM 2501-05 REAR PORCH, LOOSE AND WEAK RAILS, INADEQUATE CONNECTIONS AT TOP AND BOTTOM OF STRINGERS, MISSING BOLTS AT STRINGER AGAINST THE WALL, PERMIT REQUIRED FOR REPAIRS. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
REPLACE D&H PORCH 2 REAR PORCHES DANGEROUS AND HAZARDOUS. 4456-58 REAR PORCH, DANGEROUS AND HAZARDOUS, INPROPER FOOTINGS, 2X8 JOIST AT 10' SPAN, 6X6 BEAMS AT 8' SPAN, CRACKED AND ROTTED STRINGERS WITH SCABBING THRU OUT; LOOSE ,WEAK AND ROTTED RAILS, RAILS UNDER 42", BUCKLED AND OVER NOTCHED COLUMNS, OPEN FIRE CUTS, BEAM POCKET OVER WINDOW, ROOF AND DECK JOIST OVER 16" ON CENTER, ROTTED ROOF SHEETING; LOOSE AND WEAK TREADS. PLANS AND PERMIT ARE REQUIRED FOR REPLACEMENT. 2507-11 REAR PORCH, DANGEROUS AND HAZARDOUS, MISSING AND INADEQUATE FOOTINGS, 2X8 JOIST AT 10' SPAN, JOIST OVER 16" ON CENTER, 6X6 BEAMS AT 8' SPAN; OVER NOTCHED COLUMNS; BUCKLED, TWISTED AND ROTTED COLUMNS, ROT AT FIRE CUTS; LOOSE, WEAK AND ROTTED RAILS, RAILS UNDER 42", UNSOUND BEAM POCKETS, CRACKED STRINGERS, LOOSE AND WEAK TREADS. PLANS AND PERMIT ARE REQUIRED FOR REPLACEMRNT. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER 2501 BASEMENT UNIT, LOOSE PLASTER ON WALLS AND CEILINGS THRU OUT. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH ROTTED WINDOW SASHES THRU OUT. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
MAINTAIN WINDOW ROTTED WINDOW FRAMES THRU OUT 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
SCREEN OUTER DOORS, WINDOWS 2501 BASEMENT UNIT, SCREENS DO NOT CLOSE PROPERTY. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
INSECTS 2501 BASEMENT UNIT, INSECTS. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
REMV OBSTR FROM DRAINAGE SYSTM 2501 BASEMENT UNIT, CLOGGED KITCHEN SINK. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
INSPECT CONSTRUCTION WORK PLANS AND PERMIT NOT ON SITE FOR INSPECTORS REVIEW AT TIME OF INSPECTION. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR SIDE LITE PLEXIGLASS LOOSE. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING WATER DAMAGED. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED FROM 2005 THRU 2011. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
REPAIR SCREENS SCREEN TORN. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS BROKEN BASEMENT WINDOWS THRU OUT. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
REPUTTY WINDOW PANES REPUTTY WINDOWS THRU OUT. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. 2501 W SUNNYSIDE AVE COMPLAINT FAILED View