The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | POST OWNER / MANAGER'S COMPLETE I.D. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | 3 LEVEL REAR PORCH - 1ST LEVEL SUPPORT BEAMS DAMAGED, REMOVED - MAKE - SHIFT KNEE WALL PUT IN PLACE OF STRUCTURAL BEAMS. WORK NOT FINISHED WORK SO FARE IS UNPROFESSIONAL. PORCH IS NOW IN DANGER OF COLLAPSE. DANGEROUS AND HAZARDOUS. ALSO - NO BOLTS AT ALL LEDGER BEAMS (COLLAPSE HAZARD) AT 2ND, 3RD FLOORS - BEAMS ARE SCAB - CONNECTED TO COLUMNS - COLLAPSE HAZARD. THIS PORCH SYSTEM UNSAFE FOR HUMANS TO TREAD UPON - DANGEROUS AND HAZARDOUS. ALL BANISTERS TOO LOW (38"). PLANS AND PERMITS. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | FOR PORCH REPAIRS. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | MISSING MANAGEMENT INFO SIGN | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH: UNDERSIZED JOIST, LEDGERS, RAILS, BEAMS, USING 2X8 AT COLUMN AT LANDINGS, DECKS DEFLECT UNDER LOAD, RAILS DEFLECT UNDER LOAD, MISSING BOLTS IN LEDGER BOARDS-NAILS ONLY, LEDGERS PULLING AWAY FROM BUILDING, STACKED COLUMNS WITH 2X4 SCABBING HOLDING COLUMNS TOGETHER, SCABBING THRU-OUT, OVERCUT STRINGERS, UNEQUAL RISE OF STAIRS, WRONG NAILS USED IN JOIST HANGERS-PORCH IS IN A DANGEROUS & HAZARDOUS CONDITION | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PLANS & PERMITS FOR NEW PORCH TO BE BUILT | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR TO VERIFY OCCUPANCY & DETECTORS | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
SECOND ISSUED - STOP ALL CONSTRUCTION WORK PERFORMED AT SITE WITHOUT A PERMIT. SEC. 13-12-080; 13-32-035 | 3222 W PIERCE AVE | COMPLAINT | FAILED | View | |
PLANS & PERMITS REQ - CONTRCTR | ACQUIRE PLANS AND PERMITS FOR BUT NOT LIMITED TO: 1) REAR EXTERIOR PORCH REPAIRS TO 3 STORY WOOD FRAME PORCH 20' X 10' BY 3 STORY; 2) INTERIOR BASEMENT NEW WOOD FRAME PARTITIONS FORMING ROOMS, PARTIALLY COVERED WITH DRYWALL; 3) STRUCTURAL ALTERATIONS TO BASEMENT. FIRE DAMAGED COLUMN AND BEAM, (LOAD-BEARING), CEILING JOIST. REPLACED WITH STEEL POST, I-BEAM AND SISTERED WOOD JOIST; 4) 1ST FLOOR PARTITIONS REMOVED, BATHROOM FLOOR REBUILT NEW JOIST AND SUB-FLOOR. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | ACQUIRE PERMIT FOR BUT NOT LIMITED TO THE INSTALLATION/REPLACEMENT OF PLASTER WITH DRYWALL AT 1ST FLOOR APARTMENT THROUGHOUT WALLS. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | AT KITCHEN SINK | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | DOORS MISSING VIEW DEVICE. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | 2ND MISSING SCREENS. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT MISSING HANDRAIL. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH AT 2ND FLOOR LANDING HAS A LARGE HOLE IN DECKING BOARDS. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH: STRINGERS, LOOKOUTS, BEAMS AND RAIL NOT BOLTED. RAIL HEIGHT 38" SHOULD BE 42". PICKETS MISSING AT GRADE TO BASEMENT. JOIST HANGERS MISSING AT VARIOUS LOCATIONS. LEDGERS NOT ANCHORED WITH BOLTS TO BUILDING. SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | ACCUMULATION OF DEMO DEBRIS AT REAR PORCH AND YARD. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ARRANGE FOR INTERIOR INSPECTION TO VERIFY OCCUPANCY. | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |
STOP ALL CONSTRUCTION WORK PERFORMED WITHOUT A PERMIT. SEC. 13-12-080; 13-32-035 | 3222 W PIERCE AVE | COMPLAINT | FAILED | View |