The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | BASEMENT/ MADE INTO APT WITH FULL KITCHEN . SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZED ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | ATTIC AND BASEMENT / VIWEWING DEVICE MISSING . | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | BASEMENT MADE INTO APT WITH FULL KITCHEN . REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING ELECTRICAL INSTALLED IN WITHOUT A PERMIT | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | REAR /NTERIOR STAIR -GRADE TO ATTIC - NEW BUILT . PLANS AND PERMIT REQUIRED FOR NEW INTERIOR STAIR . | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BASEMENT APT / SMOKE DETECTOR - OUT OF SERVICE . | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INSP CONDIATIONS AND DETECTORS. | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTH ELVATION / NEW WOOD FENCE - 120 FTX 6FT HIGH . PERMIT REQUIRED FOR NEW FENCE. | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN - MISSING. | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS , CONDITIONS , AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REAR AND SIDE YARDS - 5'10'' WOOD AND METAL FENCE BUILT - NO PERMIT OBTAINED. | 4716 S KILDARE AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS , CONDITIONS , AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 4716 S KILDARE AVE | COMPLAINT | PASSED | View |
RELOCATE SMOKE DETECTOR | BASEMENT /SMOKE DETECTOR - RELOCATE SMOKE DETECTOR INSTALLED ON THE WALL TOO CLOSE 2 INCHES TO CEILING. BASEMENT LAUNDRY ROOM [AT REAR] /RELOCATE SMOKE DETECTOR INSTALLED ON THE WALL ABOVE EXTERIOR WINDOW.1ST. FL. /SMOKE DETECTOR - RELOCATE SMOKE DETECTOR INSTALLED TOO LOW 26 INCHES FROM CEILING ON THE WALL.REAR ENCLOSED PORCH [2ND. FL./ATTIC] /RELOCATE SMOKE DETECTOR INSTALLED TOO LOW 56 INCHES FROM CEILING ON THE WALL.REAR ENCLOSED PORCH [1ST. FL.] /RELOCATE SMOKE DETECTOR INSTALLED TOO LOW 28 INCHES FROM CEILING ON THE WALL. | 4716 S KILDARE AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | REAR 2 STORY WOOD ENCLOSED STAIR SYSTEM.RAILINGS /GRADE TO 1ST. FL. /STAIR RAIL SECTION - MISSING. 1ST. FL. /GUARD RAIL SECTION - MISSING. 1ST. FL. /GUARD RAIL SECTION - UNDERSIZED, WITH PICKETS SPACED UP TO 6 INCHES APART.STAIRS /1ST. FL. TO INTERMEDIATE LANDING - 9 1/2 INCH TREADS - BACK PITCHED, UNEVEN, TRIP HAZARD. INTERMEDIATE LANDING - 11 1/2 INCH TREADS - RISER HEIGHT NOT UNIFORMED, RANGING FROM 2 INCHES TO 10 INCHES TO 14 INCHES. TRIP HAZARD. | 4716 S KILDARE AVE | COMPLAINT | PASSED | View |
PERMIT REQUIRED | OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO [BASEMENT WALLS ERECTED CREATING 1 BEDROOM AND WASHROOM, WITH TOILET, SINK AND SHOWER] AND [ATTIC WALLS ERECTED CREATING 2 BEDROOMS] OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES.EPP PERMIT REQUIRED ONLY. | 4716 S KILDARE AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. UNABLE TO VERIFY COMPLAINT OF ILLEGAL ATTIC APT. WITH MULTIPLE NON FAMILY DWELLERS IN UNSAFE ATTIC WITH ONE EXIT. FRONT AND REAR GATES ARE LOCKED, UNABLE TO VERIFY CONDITON OF REAR YARD. | 4716 S KILDARE AVE | COMPLAINT | FAILED | View |