Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING /OWNER¿S I.D. SIGN ¿ MISSING. | 8134 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | FRONT ELEVATION /METAL WINDOW LINTELS - RUSTED THRU CAPPING. MOST WINDOW LINTELS CAPPED WITH METAL, UNABLE TO INSPECT CONDITIONS. | 8134 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EAST AND SOUTHEAST ELEVATIONS /EXTERIOR WALLS - SPALLING BRICK, WITH WASHED OUT MORTAR. | 8134 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST ELEVATION /STONE WINDOW SILLS - FRACTURED, WITH WASHED OUT MORTAR. | 8134 S EBERHART AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION /2ND. FL. WINDOW - BROKEN. | 8134 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE /EAST AND SOUTH ELEVATIONS - EXTERIOR WALLS - SPALLING BRICK, BROKEN, CRACKED PARGED, WASHED OUT MORTAR. EAST ELEVATION /WINDOWS - BOARDED UP. SOUTH ELEVATION /PARAPET WALL - WASHED OUT MORTAR. ALL OVERHEAD DOORS X6 - BOARDED UP WITH ROTTED PLYWOOD. | 8134 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | BUILDING THROUGHOUT /WINDOW SCREENS - RIPPED - MISSING. | 8134 S EBERHART AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2009 THRU 2017. | 8134 S EBERHART AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 3 STORY OPEN WOOD PORCH WITH ROOF. -FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE SLAB AND BASES FORMED BY CONCRETE POURED IN AROUND COLUMN, WITH NO BASES; FOUNDATION STATUS UNKNOWN. -COLUMNS /INADEQUATE HALF-LAP JOINTS WITH OVERLAP OF ONLY 12 INCHES, WITH ONLY 2 BOLT USED OF 1/2 INCHES IN DIAMETER. OVER NOTCHED WITH FIRE CUTS AND RIM JOISTS CONNECTIONS OCCURRING AT THE SAME LOCATION OR IN CLOSE PROXIMITY AND ONLY 4 INCHES APART.-BEAMS /ROTTING, SAGGING AT FIRE CUT, PULLING OUT OF FIRE CUTS.-ROOF BEAMS /STACKED ON TOP OF COLUMNS, FASTENED WITH NAILS/SCREWS ONLY.-DECK JOISTS /SINGLE 2X HEADER JOIST [AT STRINGER] FASTENED TO RIM JOISTS, WITH NAILS/SCREWS ONLY. -STRINGERS /UPPER AND LOWER ENDS OF STRINGERS, FASTENED WITH NAILS/SCREWS ONLY. -STAIRS /TREADS AND RISERS - CRACKED, BROKEN, ROTTED, WEAK. RISERS - UNEVEN. PORCH UNSTABLE, LANDING ¿ EXCESSIVE PULLING, SWAYING. -DECKING /PLYWOOD USED AS DECKING MATERIAL [FOR UNENCLOSED EXTERIOR PORCH SYSTEM]. -RAILINGS [UNDERSIZED] /RAILING SECTIONS - LOOSE AND PULLING, DEFLECTING UNDER LOAD, WITH TOP AND BOTTOM RAILS PULLING. RAILINGS SCABBED WITH ROTTED PLYWOOD. PICKETS /SPACED UP TO 5 INCHES APART. PICKETS /SECTIONS - LOOSE AND MISSING. GRADE TO BASEMENT /RAILING SECTIONS - MISSING.PLANS AND PERMIT REQUIRED TO REPLACE REAR 3 STORY OPEN DANGEROUS & HAZARDOUS WOOD PORCH WITH ROOF. REAR 3 STORY ENCLOSED WOOD PORCH.-FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE SLAB AND BASES FORMED BY CONCRETE POURED IN AROUND COLUMN, WITH NO BASES; FOUNDATION STATUS UNKNOWN. -BEAMS /ROTTING, SAGGING AT FIRE CUT, PULLING OUT OF FIRE CUTS.PLANS AND PERMIT REQUIRED TO REPLACE REAR 3 STORY ENCLOSED DANGEROUS & HAZARDOUS WOOD PORCH. | 8134 S EBERHART AVE | COMPLAINT | FAILED | View |