Chicago Building Violations Data: 29 Violations
Violation Inspector Comments Address Category Status View
SEND EX. METAL LETTER ENGINEER REPORT 6912 W BELMONT AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS BASEMENT MISSING SMOKE DETECTOR. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. 6912 W BELMONT AVE COMPLAINT PASSED View
PROVIDE TEMPERING VALVES ON MEN AND WOMENS LAVATORIES. (18-29-607.1.1) 6912 W BELMONT AVE COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE SUPPLIES TO KITCHEN FAUCET, LAVATORY AND TOILET, APARTMENT 1ST FLOOR NORTH ELEVATION. 6912 W BELMONT AVE COMPLAINT PASSED View
INTERIOR FINISH FIRERESISTANCE INTERIOR OF TAVERN HAS WOOD PANELING COVERING WALL LACKING PROPER FIRE RATING. (15-8-370, 15-12-340) 6912 W BELMONT AVE COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY EAST MARKED EXIT AT 35" REQUIRES A 36" OPENING. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. 6912 W BELMONT AVE COMPLAINT PASSED View
1HR FLR OVER BSMT, 1 OR 2 DU BASEMENT CEILING HAS A TOTAL LACK OF FIRE SEPARATION TO COMMERCIAL SPACE ABOVE. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. 6912 W BELMONT AVE COMPLAINT PASSED View
PROVIDE HOT WATER TANK IN BASEMENT HAS A BACKPITCHED FLUE PIPE WHICH POSES A DANGEROUS AND HAZARDOUS CONDITION. (18-28-803.10.5) 6912 W BELMONT AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM EAST INTERIOR STAIR 1ST FLOOR TO BASEMENT HAS UNDERSIZED STAIR TREADS. 6912 W BELMONT AVE COMPLAINT PASSED View
REPAIR FLOOR FLOOR BEHIND BAR HAS DEFLECTION WHEN STEPPING ON. 6912 W BELMONT AVE COMPLAINT PASSED View
CARB MONOX DETECT IN RESID BASEMENT NON-WORKING CARBON MONOXIDE DETECTOR. THIS POSES A DANGEROUS AND HAZARDOUS CONDITION. 6912 W BELMONT AVE COMPLAINT PASSED View
CHIMNEY CAPPING CHIMNEY CAP MISSING. 6912 W BELMONT AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR EAST EXTERIOR STAIRS MISSING A HANDRAIL. 6912 W BELMONT AVE COMPLAINT PASSED View
SERVICE WALK, PASSAGE, AREAWAY SERVICE WALK HAS BROKEN AND SHIFTING CONCRETE CAUSING A TRIP HAZARD. 6912 W BELMONT AVE COMPLAINT PASSED View
PROPER MATRL WATER SUPPLY PIPE REMOVE FLEXIBLE SUPPLIES TO LAVATORY AND TOILET MEN AND WOMEN'S RESTROOM, LAUNDRY TUB EAST ELEVATION, 1ST FLOOR. 6912 W BELMONT AVE COMPLAINT PASSED View
REPLACE DEFECTIVE TRAP REMOVE PVC P-TRAP LAVATORIES MEN AND WOMEN'S RESTROOM. 6912 W BELMONT AVE COMPLAINT PASSED View
STOP ODORS RPR DFT SEWAGE SYS SEWER GAS SMELL MENS ROOM, DANGEROUS CONDITION. 6912 W BELMONT AVE COMPLAINT PASSED View
SOIL/WASTE,VENT PIPE MATRL REMOVE 4" PVC WASTE PIPE BASEMENT WEST ELEVATION. 6912 W BELMONT AVE COMPLAINT PASSED View
REMOVE 2" FERCO COUPLING BASEMENT WEST ELEVATION. (18-29-705.1.4) 6912 W BELMONT AVE COMPLAINT PASSED View
PROVIDE 21" CLEARANCE FROM FRONT OF TOILET TO SIDE OF LAVATORY RESTROOM, APARTMENT NORTH ELEVATION. (18-29-405.3.1) 6912 W BELMONT AVE COMPLAINT PASSED View
LICENSED BONDED PLMBG CONTRCTR OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. 6912 W BELMONT AVE COMPLAINT PASSED View
SYSTEM III TOTALLY LACKING EMERGENCY LIGHTING SYSTEM III. INSTALL CHICAGO APPROVED EXIT SIGNS AND EMERGENCY LIGHTS - DANGEROUS CONDITION. 6912 W BELMONT AVE COMPLAINT PASSED View
INSTALL COVERS INSTALL COVER TO OPEN JUNCTION BOX AT BASEMENT STAIRWELL - DANGEROUS CONDITION. 6912 W BELMONT AVE COMPLAINT PASSED View
UNAPPROVED CORDS REMOVE ALL UNAPPROVED EXTENSION CORDS AND POWER STRIPS AND INSTALL ADDITIONAL RECEPTACLES TO AVOID USE OF CORDS - DANGEROUS CONDITION. 6912 W BELMONT AVE COMPLAINT PASSED View
PROVIDE AIR CHAMERS LAUNDRY WATERS HOT AND COLD BASEMENT EAST ELEVATION. 6912 W BELMONT AVE COMPLAINT PASSED View
OBTN PERMIT FOR PLUMBING WORK PERMIT FOR VIOLATIONS. 6912 W BELMONT AVE COMPLAINT PASSED View
(13-12-360) PROVIDE PERMIT TO CORRECT VIOLATIONS. 6912 W BELMONT AVE COMPLAINT PASSED View
PROVIDE 21" FRONT SHOWER BASE TO SIDE OF LAVATORY RESTROOM, APARTMENT NORTH ELEVATION. (18-29-405.3.1) 6912 W BELMONT AVE COMPLAINT PASSED View
OPEN 6912 W BELMONT AVE PERMIT PASSED View