The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR PORCH SYSTEM | 1) STRINGERS NOT BOLTED TOGETHER, AND 2) SPINDLE MISSING AT RAIL AT ATTIC LEVEL | 5115 S LAFLIN ST | PERMIT | PASSED | View |
VACANT BUILDING - REGISTER | 5115 S LAFLIN ST | COMPLAINT | CLOSED | View | |
REPUTTY WINDOW PANES | WINDOWS MISSING PUTTY THRU OUT | 5115 S LAFLIN ST | COMPLAINT | PASSED | View |
REPAIR DOOR HARDWARE | INTERIOR DOORS MISSING KNOBS THRU OUT UNIT | 5115 S LAFLIN ST | COMPLAINT | PASSED | View |
VACANT BUILDING - REGISTER | 5115 S LAFLIN ST | COMPLAINT | CLOSED | View | |
REPAIR PORCH SYSTEM | FAILED: 1) HANDRAIL HEIGHT ONLY 28"-30" AT NOSING; 2) SPLICE JOINTS ONLY 16" IN LENGTH, PLANS SPECIFY A MINIMUM OF 22"; 3) BOLTS MISSING AT STRINGER TO COLUMN CONNECTIONS; 4) 4X4 COLUMNS TWISTING AT RAILS FROM UPPERMOST LANDING TO ATTIC LEVEL; 5) 4X4 COLUMN AT RAILING SECTION (ATTIC LEVEL) NOT SECURED TO EXTERIOR WALL; AND 6) STRINGER FROM 3RD FLOOR TO ATTIC CUT TOO SHORT, NOT ENOUGH ROOM TO "SAFELY" BOLT STRINGER TO COLUMN. | 5115 S LAFLIN ST | PERMIT | PASSED | View |
REPAIR PORCH SYSTEM | FAILED: 1) HANDRAIL HEIGHT ONLY 28"-30" AT NOSING; 2) SPLICE JOINTS ONLY 16" IN LENGTH, PLANS SPECIFY A MINIMUM OF 22"; 3) BOLTS MISSING AT STRINGER TO COLUMN CONNECTIONS; 4) 4X4 COLUMNS TWISTING AT RAILS FROM UPPERMOST LANDING TO ATTIC LEVEL; 5) 4X4 COLUMN AT RAILING SECTION (ATTIC LEVEL) NOT SECURED TO EXTERIOR WALL; AND 6) STRINGER FROM 3RD FLOOR TO ATTIC CUT TOO SHORT, NOT ENOUGH ROOM TO "SAFELY" BOLT STRINGER TO COLUMN. | 5115 S LAFLIN ST | PERMIT | PASSED | View |
REPLACE D&H PORCH | UNABLE TO VIEW FOUNDATION BECAUSE OF ENCLOSED 1ST FLOOR.JOIST ARE 2 BY 8 AND SPAN OVER 12 FEET. BEAMS ARE 6 BY 6 WITH LIGHT GAGE METAL STRAPS AT FIRE CUTS. COLUMNS ARE OVER NOTCHED AT FIRE CUTS. HALF LAP JOINTS HAVE 1/4 INCH BOLTS. RAILS MISSING CENTER SUPPORTS, TOE NAILED TO COLUMNS AND END SUPPORTS ARE MASONRY NAILED TO BRICXK WALL, RAILS ARE MISSING PICKETS AT 2ND AND 3RD FLOORS TOP AND BOTTOM RAILS ARE ROTTED,LOOSE AND PULLING.STRINGERS ARE FACE NAILED,TREADS ARE CUPED WITH NAILS POPPING. DECKING BOARDS ARE SPLITTING WITH WEAK AND CUPED BOARDS. PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT OF DILAPIDATED AND DANGEROUS PORCH. PORCH WAS POSTED. | 5115 S LAFLIN ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR FRAME | ENTRY DOOR SPLIT FRAME. | 5115 S LAFLIN ST | COMPLAINT | PASSED | View |
WINDOW OPEN EASILY, STAY OPEN | CENTER BEDROOM WINDOW WILL NOT STAY OPEN | 5115 S LAFLIN ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR | 5115 S LAFLIN ST | COMPLAINT | PASSED | View |
DEFECTIVE OUTLETS | OUTLETS MISSING COVERS INBED ROOMS | 5115 S LAFLIN ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FAUCET | BATHROOM TUB HOT WATERHANDLE MISSING | 5115 S LAFLIN ST | COMPLAINT | PASSED | View |