Last Modification Date: 2024-10-22 @ 9:47 AM
PIN: 16232050360000
Property Address: 1236 S SPAULDING AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77113
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 20 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# BUILDING/OWNERS ID SIGN -MISSING. 1236 S SPAULDING AVE COMPLAINT FAILED View
REPAIR CORNICE EAST ELEV./ METAL CORNICE-SECTIONS LOOSE AND ROTTING 1236 S SPAULDING AVE COMPLAINT FAILED View
PARAPET & COPING SOUTH ELEV/PARAPET WALL- SPALLING BRICKS, WASHED OUT MORTAR. 1236 S SPAULDING AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL NORTH AND SOUTH ELEV/ EXT. WALL-FRACTURED MASONARY, SPALLING BRICKS, WASHED OUT MORTAR. 1236 S SPAULDING AVE COMPLAINT FAILED View
EXPOSED WIRING SOUTH ELEV/ ELECTRIC SERVICE METER-COVER MISSING. 1236 S SPAULDING AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM FRONT EXT PORCH/COLUMNS-ERECTED ON CONCRETE SLAB,FOUNDATION UNKNOWN. COLUMNS-OUT OF PLUMB AND BOWING. COLUMNS-INADEQUATE HALF LAP JOINTS (12") NAILED ONLY, WITHOUT ANY BOLTS USED.BEAM TO COLUMN CONNECTIONS- OVERCUT, FILLED WITH CAULK, NAILED ONLY,WITH METAL GUSSETT. BEAM TO COLUMN CONNECTION AT ROOF- COVERED WITH SCABBED WOOD, CONNECTIONS NOT VISIBLE. RIM JOIST/AT ROOF- ROTTING RIM JOIST/3RD FLR. -SPLITING RAILING SYSTEMS- TOE NAILDED ONLY, ONLY 36" HIGH STAIR HEADERS, DECK JOISTS, AND RIM JOISTS UNDERSIZED 2"X6" USED OVER 8' SPANS. TREADS- 91/4" WIDE, SOME BROKEN, CUPPED, AND WORN OUT, PLANS AND PERMIT REQUIRED FOR FRONT AND REAR PORCH REPAIRS. 1236 S SPAULDING AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER SOUTH ELEV. THROUGHWAY- MISSING PLASTER/GYPSUM BOARD, 1ST FLR. FRAMING EXPOSED. 1236 S SPAULDING AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INT. OF BUILDING- NO RESPONSE, UNVERIFIED DET. UNVERIFIED COMPLAINT OF NO HOT WATER/ INFESTED WITH ROACHES AND MICE. UNABLE TO INSPECT INT. STAIRWAYS. 1236 S SPAULDING AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION EXTERIOR WALL ERODED MORTAR JOINTS,WEST ELEVATION EXTERIOR WALL OPEN BEAM POCKETS. 1236 S SPAULDING AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO OWNER I D SIGN POSTED. 1236 S SPAULDING AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR FRONT GATE DOUBLE KEY LOCK. 1236 S SPAULDING AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS EAST ELEVATION WINDOW SILLS OPEN MORTAR JOINTS. 1236 S SPAULDING AVE COMPLAINT FAILED View
PARAPET SOUTH ELEVATION PARAPET WALL OPEN MORTAR JOINTS AND SPALLING BRICK. 1236 S SPAULDING AVE COMPLAINT FAILED View
EXPOSED WIRING SOUTH ELEVATION ELECTRICAL METER MISSING COVER. 1236 S SPAULDING AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER AREA WAY CEILING EXPOSED FRAMING. 1236 S SPAULDING AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE SOUTH ELEVATION SERVICE WALK BROKEN GLASS,GARBAGE. 1236 S SPAULDING AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING, NO RESPONSE TO VERIFY DETECTORS AND COMPLAINT OF SINK LEAKING AND MICE INFESTATION. 1236 S SPAULDING AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS EAST ELEV./ ALL LEVELS/SILLS- WASHED OUT MORTAR. 1236 S SPAULDING AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR FRONT YARD GATE- DOUBLE KEY LOCK. 1236 S SPAULDING AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE SOUTH ELEV./ SERVICE WALK- BROKEN GLASS BOTTLES, AND PAPERS. 1236 S SPAULDING AVE COMPLAINT FAILED View