The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED YEARS 1990 THRU 2012. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - WASHED OUT MORTAR.SOUTHWEST CORNER - VERTICAL FRACTURE AND FACE BRICK SHIFTING.MASONRY REPAIR PERMIT REQUIRED. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | SOUTH EXTERIOR STAIRS, SIDEWALL - WASHED OUT MORTAR. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR | 2540 W./ FRONT EXTERIOR DOOR FRAME - ROTTED EXTERIOR MOULDING. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR | SOUTH AT 1ST - ENTRY DOOR - RUSTED AT BOTTOM WITH 1'' GAP AT SILL. FRONT BALCONY AT 1ST - SCREEN DOOR - LOOSE AND HANGING. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR FRAME | SOUTH ENTRY DOOR FRAME AT 1ST - SIDE LITES - GLASS PANES - CRACKED. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | SOUTH BRICK WALL - WASHED OUT MORTAR. SOUTHWEST CORNER - VERTICAL FRACTURE AND FACE BRICK SHIFTING . MASONRY REPAIR PERMIT REQUIRED FOR MASONRY REPAIRS. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
PARAPET | NORTH AND WEST PARAPETS - WASHED OUT MORTAR WITH SHIFTING BRICKS. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPUTTY WINDOW PANES | EAST WINDOWS - LOOSE , BROKEN , AND MISSING PUTTY. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW SASH | EAST WINDOW SASHES - ROTTED WITH PEELING PAINT. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST AT 3RD - WINDOW - BROKEN PANE. SOUTH AT 1ST - WINDOW - BROKEN PANE. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | NORTHEAST BASEMENT STAIRWAY - GRADE TO BASEMENT AT GRADE - GUARDRAIL SECTIONS - MISSING. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
INSTALL DOOR VIEWING DEVICE | FRONT INTERIOR STAIRWAY 2ND AND 3RD - APARTMENT ENTRY DOORS - VIEWING DEVICE - MISSING. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
PRV FLOOR DRAIN WITH METAL STR | EAST SERVICE WALK - FLOOR DRAIN - MISSING STRAINER COVER - TRIP HAZARD. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN - MISSING. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
ILLUMINATE EXIT AREAS | SOUTH EXTERIOR STAIRWAY GRADE TO 1ST - NO EXTERIOR LIGHT FIXTURE PROVIDED. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | FRONT INTERIOR STAIRWAY AT TOP OF STAIRWAY - SMOKE DETECTOR - MISSING BATTERY AND COVER - OUT OF SERVICE. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR BALCONY | SOUTH BALCONY - WASHED OUT MORTAR. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY OPEN WOOD PORCH - ALL MEMBERS ROTTED AND DETERIORATED. COLUMNS ERECTED ON CONCRETE SLABS - FOUNDATION STATUS UNKNOWN. COLUMNS ARE STACKED , SPLIT , ROTTED , BOWED , AND TWISTED. BEAM TO COLUMN CONNECTIONS ONLY NAILED. FIRE CUTS AND BEAM CUTS IN COLUMNS ARE IN CLOSE PROXIMITY TO EACH OTHER [ OVERNOTCHED COLUMNS ]. COLUMN PULLING AWAY FROM BEAM AT 2ND. UNDERSIZED 6 X 6 BEAMS SPAN 6' 4''. UNDER SIZED 2 X 8 DECK JOISTS SPAN 15' 4'' AND 12' 9''. STRINGERS ONLY NAILED TO HEADER JOISTS , DECK JOISTS AND COLUMNS. TREADS - ROTTED , SPLIT , LOOSE , AND WORN. GUARDRAILS AND HANDRAILS - ROTTED WITH PEELING PAINT , LOOSE AND DEFLECTING 2'' TO 4'' - ONLY NAILED TO BUILDING AND COLUMNS. GUARDRAILS ONLY 36'' HIGH. DECKING IS ROTTED , BUCKLED , LOOSE , AND SPONGY WITH HOLES AND MISSING WOOD SECTIONS - TRIP AND FALLING HAZARD. PORCH IS WEAK AND SWAYS. PLANS AND PERMIT REQUIRED FOR PORCH REPAIRS. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - REFUSED ENTRY - APARTMENTS - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT ALL INTERIOR STAIRWAYS. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR ROOF STRUCTURE | REAR PORCH ROOF SHEATHING - BROKEN , ROTTED , AND MISSING SECTIONS . | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 1990 THROUGH 2012. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
RAT PROOF BSMENT DOOR | EAST BASEMENT DOOR - HAS A HOLE (BOTTOM). | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOWS SCEENS TORN AND MISSING. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
PARAPET | WEST AND EAST PARAPET WALL WASHED OUT MORTAR AND SPALLING BRICKS. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 1W AT FRONT BROKEN PANES. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | GATE CHAIN AND PADLOCK. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | EAST SASHES WORN. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR SCREENS | 1 FRONT BROKEN STORM DOOR. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO ENTRY, UNABLE TO VERIFY COMPLAINT SR150161376. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR FRONT APT. - MISSING SMOKE DETECTOR. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
STOP ODORS RPR DFT SEWAGE SYS | SOUTHWEST INTERIOR STAIRWAY (FRONT) - SEWER ODORS. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
MAINTAIN WINDOW SASH | EAST WINDOW SASHES - ROTTED WITH PEELING PAINT. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
STOP LEAKING WATER | 1ST FLOOR FRONT APT. KITCHEN SINK DRAIN - LEAKING. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST FRONT WALKWAY - CONCRETE HAS CRACKS AND HOLES. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
DEBRIS, EXCESSIVE | EAST PORCH AND WEST INTERIOR STAIRWAY - JUNK AND REFUSE ACCUMULATION, INCLUDING DISCARDE GAS STOVE. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPUTTY WINDOW PANES | EAST WINDOWS - LOOSE, BROKEN AND MISSING PUTTY. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
RAT PROOF BSMENT DOOR | EAST BASEMENT DOOR - HAS A HOLE (BOTTOM). | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR FLOOR | 1ST FLOOR FRONT APT. KITCHEN - ROTTED SUBFLOOR AND MISSING FLOOR TILES. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR/REPLACE SMOKE DETECTORS | FRONT INTERIOR STAIRWAYS - SMOKE DETECTORS - MISSING BATTERY AND COVERS. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - MISSING OWNER'S ID. SIGN. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR BALCONY | SOUTH BALCONY - WASHED OUT MORTAR, RUSTED LINTELS, LOOSE CEILING ALUMINUM PANELS AND WASHED OUT MORTAR ON COPING STONES. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | NORTH AND WEST WINDOW SILLS - WASHED OUT MORTAR. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
ILLUMINATE PUBLIC STAIR/HALL | FRONT (SOUTH) EXTERIOR STAIRS GRADE TO 1ST - MISSING EXTERIOR LIGHT FIXTURES. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | FRONT 1ST FLOOR BALCONY STORM DOOR - OFF HINGES.SOUTHEAST EXTERIOR MAIN ENTRY DOOR - BROKEN LITE GLASS PANES, DOOR HITTING DOOR JAMB, RUSTED (BOTTOM) AND LOOSE THRESHOLD. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION 1ST FLOOR - BROKEN WINDOW PANES. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
MAINTAIN WINDOW SASH | EAST WINDOW SASHES - ROTTED WITH PEELING PAINT. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPUTTY WINDOW PANES | EAST WINDOWS - LOOSE, BROKEN AND MISSING PUTTY. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS - MISSING SEVERAL WINDOW AND DOOR SCREENS.. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | SOUTH EAST VESTIBULE, INTERIOR STAIRWAY AND 1ST FLOOR FRONT APT. LIVINGROOM, BEDROOM, BATHROOM AND KITCHEN WALLS AND CEILINGS, PLASTER HAS HOLES, BUCKLED PLASTER AND PEELING PAINT. 1ST FLOOR FRONT KITCHEN - BROKEN CABINETS. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR FRONT APT. KITCHEN - ROTTED SUBFLOOR AND MISSING FLOOR TILES. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
STOP LEAKING WATER | 1ST FLOOR FRONT APT. KITCHEN SINK DRAIN - LEAKING. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
STOP ODORS RPR DFT SEWAGE SYS | SOUTHWEST INTERIOR STAIRWAY (FRONT) - SEWER ODORS. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR FRONT APT. - MISSING SMOKE DETECTOR. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | FRONT INTERIOR STAIRWAYS - SMOKE DETECTORS - MISSING BATTERY AND COVERS. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | WEST FRONT WALKWAY - CONCRETE HAS CRACKS AND HOLES. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 2ND AND 3RD FRONT APTS. ENTRY DOORS - MISSING VIEWING DEVICES. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST EXTERIOR 3 STORY WOOD PORCH: UNDERSIZED 6"X6" BEAMS SPAN 6'-6" ARE SCABBED AND ONLY TOE NAILED TO COLUMNS.; UNDERSIZED 2"X8" DECK JOISTS SPAN 13'-2-1/2".; COLUMNS HALF LAP JOINTS ARE ONLY 12" LONG AND FASTENED WITH ONE TO 4 BOLTS OTHERS ARE STACKED ONE ON TOP OF OTHERS.; 3RD FLOOR DECK IS SEPARATING FROM EXTERIOR WALL.; 2ND FLOOR DECK HAS A HOLE AND IS BUCKLING.; STAIR AND DECK RAILINGS ARE LOOSE, PULLING, ONLY TOENAILED TO RAILING POSTS AND COLUMNS, SECTIONS OVER 4'-0" LONG MISSING INTERMEDIATE SUPPORTS (4"X4" POSTS).;GUARDRAILS ARE ONLY 36" HIGH.;2ND FLOOR SPLIT TREAD.PLANS AND PERMIT ARE REQUIRED TO REPAIR PORCH. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE ROOF EAVES - MISSING FASCIA AND SOFFIT BOARDS. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EAST EXTERIOR STAIRS GRADE TO BASEMENT - MISSING HANRAILS (HAVE HANDRAILS ON ONE SIDE ONLY). | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | EAST PORCH AND WEST INTERIOR STAIRWAY - JUNK AND REFUSE ACCUMULATION, INCLUDING DISCARDE GAS STOVE. | 2540 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS - MISSING SEVERAL WINDOW AND DOOR SCREENS.. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE ROOF EAVES - MISSING FASCIA AND SOFFIT BOARDS. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | EAST EXTERIOR 3 STORY WOOD PORCH: UNDERSIZED 6"X6" BEAMS SPAN 6'-6" ARE SCABBED AND ONLY TOE NAILED TO COLUMNS.; UNDERSIZED 2"X8" DECK JOISTS SPAN 13'-2-1/2".; COLUMNS HALF LAP JOINTS ARE ONLY 12" LONG AND FASTENED WITH ONE TO 4 BOLTS OTHERS ARE STACKED ONE ON TOP OF OTHERS.; 3RD FLOOR DECK IS SEPARATING FROM EXTERIOR WALL.; 2ND FLOOR DECK HAS A HOLE AND IS BUCKLING.; STAIR AND DECK RAILINGS ARE LOOSE, PULLING, ONLY TOENAILED TO RAILING POSTS AND COLUMNS, SECTIONS OVER 4'-0" LONG MISSING INTERMEDIATE SUPPORTS (4"X4" POSTS).;GUARDRAILS ARE ONLY 36" HIGH.;2ND FLOOR SPLIT TREAD.PLANS AND PERMIT ARE REQUIRED TO REPAIR PORCH. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR INTERIOR WALLS/CEILING | SOUTH EAST VESTIBULE, INTERIOR STAIRWAY AND 1ST FLOOR FRONT APT. LIVINGROOM, BEDROOM, BATHROOM AND KITCHEN WALLS AND CEILINGS, PLASTER HAS HOLES, BUCKLED PLASTER AND PEELING PAINT. 1ST FLOOR FRONT KITCHEN - BROKEN CABINETS. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | EAST EXTERIOR STAIRS GRADE TO BASEMENT - MISSING HANRAILS (HAVE HANDRAILS ON ONE SIDE ONLY). | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
INSTALL DOOR VIEWING DEVICE | 2ND AND 3RD FRONT APTS. ENTRY DOORS - MISSING VIEWING DEVICES. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
ACCESS TO ROOF | ROOF | 2540 W AUGUSTA BLVD | PERMIT | FAILED | View |
PROVID SELF CLSING SCREEN DVCE | FRONT BALCONY AT 1ST - SCREEN DOOR - CLOSER MISSING. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | SOUTH STAIRWAY - GRADE TO 1ST - BRICK WINGWALLS WITH WASHED OUT MORTAR AND FRACTURES. NORTH STAIRWAY - GRADE TO BASEMENT - STAIR RAIL - MISSING. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
DEBRIS, EXCESSIVE | REAR PORCH - ACCUMULATION OF JUNK AND DEBRIS. | 2540 W AUGUSTA BLVD | COMPLAINT | CLOSED | View |
PARAPET | WEST, EAST AND NORTH PARAPET WALLS - SPALLING BRICKS AND MORTAR MISSING UNDER COPING TILES. | 2540 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
ARRANGE FOR INSPECTION | CALL 312-743-3562 ASK FOR INSPECTOR #653 RICH HASTINGS WEDNESDAYS BETWEEN 8:00 AND 9:00 AM. | 2540 W AUGUSTA BLVD | PERMIT | FAILED | View |