Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 1:28 AM
PIN: 13231000140000
Property Address: 3944 W DAKIN ST
City - Zip: CHICAGO - 60618
2023 Property Class: 206
2023 Township: 71 - Jefferson
2023 Neighborhood: 71070
2023 Tax District: 71128
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 23 Violations
Violation Inspector Comments Address Category Status View
PROVIDE THIS UNLICENSED ROOMING HOUSE HAS EXIT DOORS WITHOUT SELF CLOSING DEVICES.SECTION 14X-5-505 3944 W DAKIN ST COMPLAINT FAILED View
PROVIDE PROVIDE A FIRE ALARM SYSTEM FOR THIS ROOMING HOUSE. PLAANS AND PERMITS ARE REQUIRED.SECTION 907.5.2.3.3 3944 W DAKIN ST COMPLAINT FAILED View
DOOR SWING IN DIR. OF TRAVEL ALL OF THE BUILDING EXIT DOORS SWING INWARD AGAINST THE DIRECTION OF EGRESS AT THIS UMLICENSED ROOMING HOUSE.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2 3944 W DAKIN ST COMPLAINT FAILED View
SLEEPING ROOMS EACH OF THE 6 ROOMING UNITS IS UNDER THE MINIMUM REQUIRED SQUARE FEET OF LIVING SPACE.SECTION 14X-4-402.4 3944 W DAKIN ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR THIS IS A SINGLE FAMILY HOME THAT HAS BEEN ALTERED INTO A NOW EXISTING ROOMING HOUSE WITH 6 INDIVIDUAL ROOMS BEING RENTED OUT. THERE ARE NO PLANS, PERMITS, ZONING AUTHORIZATION OR LICENSE APPLICATIONS ON FILE FOR THIS CHANGE OF USE.SECTION 14A-4-401.1 3944 W DAKIN ST COMPLAINT FAILED View
1-HR HEATING PLANT ENCLOSURE THERE ARE VOIDS IN THE FIRE PROTECTION OF THE FURNACE ROOM WALLS / CEILINGS. DANGEROUS AND HAZARDOUS.SECTION 14B-5-509. 3944 W DAKIN ST COMPLAINT FAILED View
DWELLING CLEAN AND SANITARY THE GENERAL CONDITION OF THE EXTERIOR AND INTERIOR OF THIS UNLICENSED ROOMING HOUSE IS EXTREMELY UNSANITARY.THERE ARE AREAS WHERE BLACK MOLD IS GROWING ON THE WALLS AND FOOD IS ROTTING (IN VARIOUS ROOMING UNITS). THERE IS AN ENORMOUS AMOUNT OF JUNK / DEBRIS AND GARBAGE THROUGHT THIS BUILDING. THIS BUILDING DOES NOT MEET MINIMUM CODE REQUIREMENTS IN NUMEROUS CATEGORIES AND IS TO BE CONSIDERED NOT FIR FOR HUMAN HABITATIONSECTION 14X-1-103. 3944 W DAKIN ST COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING THERE ARE WATER DAMAGED WALLS / CEILINGS AT THE BASEMENT AND 1ST FLOORS. THERE IS AN EXTENSIVE BLACK MOLD CONDITION ON THE BASEMENT WALLS. THE MOLD CONDITION IS TO BE CONSIDERED A HEALTH HAZARD.SECTION 14X-3-304.3 3944 W DAKIN ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS THIS ROOMING HOUSE HAS ONLY 1 (INOPERABLE) SMOKE DETECTOR. APPROVED SMOKE DETECTORS ARE REQUIRED IN EVERY ROOMING UNIT, STAIRWELL AND FURNACE ROOM.DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.8 3944 W DAKIN ST COMPLAINT FAILED View
REPAIR EXTERIOR STAIR A STRUCTURAL COLUMN SUPPORTING THE WEST EXTERIOR EXIT STAIRS FROM THE 1ST TO 2CD FLOORS IS ROTTED AT ITS' BASE. THIS COLUMN IS NOT SET ON A GRADE LEVEL, INDEPENDENT CONCRETE COLUMN, BUT INSTEAD IS SET UPON THE 1ST LEVEL DECK BOARDS.DANGEROUS AND HAZARDOUS.SECTION 14X3-303.1.1 3944 W DAKIN ST COMPLAINT FAILED View
SYSTEM II THIS UNLICENSED ROOMING HOUSE DOES NOT HAVE AN EMERGENCY LIGHTING SYSTEM.DANGEROUS AND HAZARDOUS.SECTION 14X-7-703 / 705 3944 W DAKIN ST COMPLAINT FAILED View
STOP ODORS RPR DFT SEWAGE SYS THE OPEN PIT CATCH BASIN TIED TO THE BUILDING SEWER SUSTEM IS LOCATED IN THE INTERIOR. THERE IS A PROFOUND SYENCH OF SEWER GAS IN THE INTERIOR THAT IS EXTREMELY UNSANITARY WITH REGARD TO ITS' (SEWER GAS) EFFECT ON AIR QUALITY.DANGEROUS AND HAZARDOUS.SECTION 14X-9-902 THROUGH 14X-9-908 3944 W DAKIN ST COMPLAINT FAILED View
CLASS B DOOR IN STAIRWELL THE EXIT DOORS OF THIS UNLICENSED ROOMING HOUSE ARE NOT FIRE RATED DOORS.THE DOOR TO THE FURNACE ROOM IS NOT FIRE RATED.DANGEROUS AND HAZARDOUS.SECTION 14X-505.9.9 3944 W DAKIN ST COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY THE WEST EXTERIOR STAIRS FROM THE 1ST TO 2CD FLOOR ARE COMPLETELY OBSTRUCTED BY STORED ITEMS. ALSO, ACCESS TO THIS EXIT STAIR SYSTEM IS OBSTRUCTED BY HAVING TO PASS THROUGH A KEY LOCKED ROOMING UNIT. ALSO, THE FRONT BASEMENT EXIT DOOR, WHICH IS 6' BELOW GRADE, EGRESSES INTO A BASEMENT WELL AREA THAT DOES NOT HAVE A STAIR SYSTEM TO GRAGDE LEVEL.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2 3944 W DAKIN ST COMPLAINT FAILED View
FIRE EXTNGSHR REQ, RESDNTL THIS UNLICENSED ROOMING HOUSE HAS NO FIRE EXTINGUISHERS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.5 3944 W DAKIN ST COMPLAINT FAILED View
SAFE WORKING CONDITIONS THERE HAS BEEN UNLICENSED WORK PERFORMED ON THE GAS SUPPLY PIPING FROM THE WATER HEATER TO THE FURNACE USING NON APPROVED FLEXIBLE PIPING.DANGEROUS AND HAZARDOUS.SECTION 14X-3-305.1 3944 W DAKIN ST COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR ALL OF THE ROOMING UNIT DOORS ARE KEY LOCKED. DANGEROUS AND HAZARDOUS.SECTION 14X-505.1.2.2 3944 W DAKIN ST COMPLAINT FAILED View
INSTALL EXIT SIGN THIS UNLICENSED ROOMING HOUSE IS WITHOUT ANY EXIT SIGNS.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.6.2 3944 W DAKIN ST COMPLAINT FAILED View
STOP STORING GARBAGE THE INTERIOR OF THIS UNLICENSED ROOMING HOUSE HAS A REDUCED AMOUNT OF HABITABLE SPACE GIVING THE INORDINATE AMOUNT OF JUNK, DEBRIS AND STORED ITEMS. THE CONDITION IN SOME AREAS OF THIS ROOMING HOUSE ARE ABSOLUTELY FILTHY WITH ROTTED FOOD, DIRT AND MOLD. THE INTERIOR SPACE OF THIS BUILDING IS NOT FIT FOR HUMAN HABITATION.DANGEROUS AND HAZARDOUS.SECTION 14X-3-307 3944 W DAKIN ST COMPLAINT FAILED View
DEBRIS, EXCESSIVE THE REAR YARD AREA HAS AN ABANDONED, UNLICENSED VEHICLE AS WELL AS A LARGE AMOUNT OF JUNK / DEBRIS.SECTION 14X-1-103 3944 W DAKIN ST COMPLAINT FAILED View
REPLACE D&H PORCH THE REAR PORCH ENCLOSING THE SWIMMING POOL HAS ROTTED / DETACHED DECK BOARDS, BANISTERS THAT DEFLECT UNDER LOAD AND LOOSE / DETACHED STAIR TREADS.DANGEROUS AND HAZARDOUS.PLANS AND PERMIT ARE REQQUIRED FOR REPAIRS OR REPLACEMENT OF THIS PORCH SYSTEM.SECTION 14X3-303.1.1 3944 W DAKIN ST COMPLAINT FAILED View
ILLUMINATE PUBLIC STAIR/HALL THIS UNLICENSED ROOMIONG HOUSE HAS NO DEDICATED EXIT ILLUMINATION.DANGEROUS AND HAZARDOUS.14X-5-505.6.1 3944 W DAKIN ST COMPLAINT FAILED View
CARB MONOX DETECT IN HOTEL THIS ROOMING HOUSE HAS ONLY 1 (INOPERABLE) CARBON MONOXIDE DETECTOR.DANGEROUS AND HAZARDOUS.SECTION 14X-5-504.9 3944 W DAKIN ST COMPLAINT FAILED View