The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR SCREENS | (SR#07-01190229) ALL ELEVATIONS: SEVERAL TORN AND MISSING | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | NORTH: MOST WINDOW TRIM WITH PEELING PAINT | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | NORTH: GRAFFITI; OPEN PORCHES: BARBEQUE GRILLS ON THE LANDING AT (2) | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | NORTH: ACCUMULATION OF TRASH AND DEBRIS AT (B) (7-28-710) | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH AND EAST: WASHED OUT MORTAR, SPALLED BRICKS | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | NORTH AT (1) REAR: WINDOW IS TOO SMALL FOR THE OPENING; PERMIT IS REQUIRED FOR ALTERATION OF THE WINDOW OPENING | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | NORTH AT GRADE: WASHED OUT MORTAR, WEEDS PROTRUDING OUT FROM THE GAPS | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST PORCH: COLUMN IS RESTED ON A SPALLED CONCRETE BASE, FOUNDATION STATUS IS UNKNOWN, COLUMN IS ROTTED AT GRADE, STAIR POSTS ARE RESTED ON CONCRETE WITH ONLY ONE INCH OF BEARING, LEDGERS AND STRINGERS ARE ONLY NAILED INTO THE BUILDING, LOOSE TREADS AND RISERS, A FEW RISERS ARE SEVERELY PITCHED AND ROTTED, LOOSE HAND RAILS, LOOSE GUARD RAILS, GUARD RAILS ARE ONLY 32 INCHES IN HEIGHT, IMPROPER CONNECTIONS-MOST MEMBERS ARE TOE NAILED TOGETHER AND ARE SEPARATED AT THE CONNECTIONS; NORTH PORCH: LEDGERS AND STRINGERS ARE ONLY NAILED INTO THE BUILDING, A FEW PITCHED AND ROTTED TREADS, LOOSE HANDRAILS, IMPROPER CONNECTIONS-MOST MEMBERS ARE TOE NAILED TOGETHER AND ARE SEPARATED AT THE CONNECTIONS; PLANS AND PERMIT ARE REQUIRED FOR REPAIRS OR REPLACEMENT OF BOTH PORCH SYSTEMS | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | WEST ENTRY: PEELING PAINT; WEST STAIRWAY AT (1): BROKEN DOOR PANEL | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH AND EAST STAIRS FROM (G) TO (B): MISSING HAND RAILS | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | NORTH PORCH AT (2): EXPOSED WIRING, ALL STAIRWAYS WITH OPEN SOCKETS | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | WEST STAIRWAY FROM (G) TO (B): MISSING HAND RAILS; SOUTH STAIRWAY AT (2): LOOSE GUARD RAIL | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | WEST STAIRWAY AT (2): MISSING DETECTOR | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2752, APT. 1: MISSING DETECTOR | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 2750, APT. 2: MISSING VIEWING DEVICE | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING IS NOT REGISTERED FOR 2005-2007 | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING/MOST OF THE APARTMENTS (EXCEPT 2752 W./APT. 1): NO RESPONSE, UNVERIFIED DETECTORS; 3525 S./BASEMENT APARTMENT: UNABLE TO VERIFY COMPLAINT OF CLOGGED BATHROOM DRAIN, FOUL ODORS, AND 3X6 HOLE IN THE WALL | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO POSTING OF OWNERSHIP OLD SIGN NOT | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | STAIRWELL NO SMOKE DETECTOR | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | NO SMOKE DETECTOR AT 2752 APARTMENT 2ND FLOOR | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCH 2750-52: 1) TREADS ROTTED AND SEPARATING FROM IT'S INTENDED POSITION: 2) RISER SEPARATING FROM ITS INTENDED POSITIONS: 3) ROTTED STRINGERS: 4) NO JOIST HANGERS: 5) NO LEDGER BOLTS. THE COMPOTE TO PORCH AT 3525 ALSO: 1) ROTTED TREADS:2) HAND AND GUARD RAIL UNDER 42 INCHES: 3) NO FLOOR JOIST HANGER:4) NO LEDGER BOLTS: 5)NO FOOTING | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | SPLIT GUTTER IN REAR DUE TO DEBRIS BUILT UP IN GUTTER WHICH MADE THE ICE SPLIT GUTTER | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REMV OBSTR FROM DRAINAGE SYSTM | ROD OUT STORM DRAIN IN REAR | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
CONNECT DOWNSPOUT TO SEWER | REPLACE DOWNSPOUT | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
GAP AT BOX WALL FINISH | 3528 2ND FLOOR OPENING IN WALL ABOVE SWITCH | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
SYSTEM III | 2750 W 35 PL BATTERY LIGHT 1ST FLOOR | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | OPEN JUNCTION BOX 1ST FLOOR | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSE WIRE 1ST FLOOR | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMITS FOR PORCH REPLACEMENT | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH AT (B) FRONT: BROKEN VENT PANE | 3525 S CALIFORNIA AVE | COMPLAINT | FAILED | View |