STOP LEAKING WATER | 5115 #2 LEAKY P-TRAP KITCHEN. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHSYSTEM 5115 @SECOND LEVEL HAS MISSING HANDRAIL ROTTED STRINGER SECOND LEVEL ,PERMITS REQUIRED. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
MICE/RODENTS | 5115 W/#2 'S -MICE. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
DEFECTIVE OUTLETS | 5119 #3-S HAS DEFECTIVE WALL SWITCH. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR SIX FEET FENCE IS PADLOCKED. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPLACE DEFECTIVE FAUCET | 5115 , 2W HAS LAEKY FAUCET KITCHEN. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
DEFECTIVE OUTLETS | BROKEN LIGHT SWITCH 5113 #1 W, 5113 APT. #2 SOUTH -CEILING WATER DAMAGED -REAR BEDROOM. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | MOST OF BUILDING -INTERIOR NO RESPONSE , UNVERIFIED DETECTORS #5113 STAIRWAY DOOR BROKEN /MISSING LOCK. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
STOP LEAKING WATER | 5115 #2 LEAKY P-TRAP KITCHEN. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHSYSTEM 5115 @SECOND LEVEL HAS MISSING HANDRAIL ROTTED STRINGER SECOND LEVEL ,PERMITS REQUIRED. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
MICE/RODENTS | 5115 W/#2 'S -MICE. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
DEFECTIVE OUTLETS | 5119 #3-S HAS DEFECTIVE WALL SWITCH. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR SIX FEET FENCE IS PADLOCKED. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPLACE DEFECTIVE FAUCET | 5115 , 2W HAS LAEKY FAUCET KITCHEN. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING MISSING OWNERSHIP INFORMATION SIGN. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
RATS | 5113/ 3N AND 1N: RATS AND RODENTS PROBLEM. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING MISSING OWNERSHIP INFORMATION SIGN. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
RATS | 5113/ 3N AND 1N: RATS AND RODENTS PROBLEM. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | EAST AND WEST ELEVATION SOME BASEMENT STAIRWELLS MISSING HANDRAILS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
INSECTS | APT 5117 1 NORTH VISIBLE SIGNS OF BED BUGS. BUILDING -BED BUG INFESTATION THROUGHOUT. PROPERTY MUST BE EFFICTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | OTHER THAN 5117 1NORTH UNABLE TO GAIN ENTRY TO APTS TO VERIFY OCCUPANCY AND DETECTORS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
PERMIT REQUIRED | NORTH ELEVATION WROUGHT IRON FENCE OVER 5FT NO PEMIT ON FILE. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | OTHER THAN 5117 1NORTH UNABLE TO GAIN ENTRY TO APTS TO VERIFY OCCUPANCY AND DETECTORS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
PERMIT REQUIRED | NORTH ELEVATION WROUGHT IRON FENCE OVER 5FT NO PEMIT ON FILE. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR COPING | REAR OF BUILDING, AT ALLEY, MISSING COPING. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | SOUTH ELEVATION - WASHED OUT MORTAR, SPALLING BRICKS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | SIDE PORCH 5115-FOOTINGS ARE DEFECTIVE, BROKEN, CRACKED. COLUMNS ARE BUTT JOINTED AND TOE NAILED. MISSING BOLTS ON BEAM TO COLUMN, RAIL IS ONLY 331/2 INCHES IN HEIGHT, STRINGERS ALONG BUILDING NOT BOLTED TO BUILDING, JOISTS ARE 2X8S SPANNED AT 10 FEET 11 INCHES WITH FIRE CUTS ON BOTH ENDS. 5113 SIDE PORCH, FOOTING STATUS UNKNOWN, MISSING BOLTS ON BEAM TO COLUMN,RAIL HEIGHT 33 1/2 INCHES IN HEIGHT, STRINGER FROM 2ND TO 3RD GETTING ROTTED , BOTTOM OF RISER THAT MEETS TREADS ARE ROTTED, JOISTS ARE 2X8S SPANNED AT 10 FEET 9 INCHES, 4X4 POST ARE NOT BOLTED, THEY ARE TOE NAILED. PORCH NORTH/EAST CORNER- POOR PORCH DESIGN, 1ST FLOOR PORCH OUT OF LEVEL,HAND RAIL LOOSE ALONG STAIRS, SEE GAPS WHERE TOP RAIL MEETS POSTS. STRINGER ALONG BUILDING NOT BOLTED,(CUT NAILED) FOOTING STATUS UNKNOWN. PORCH ON SOUTH/WEST CORNER-STRINGER PULLING AWAY FROM BUILDING (SEE GAP) STAIRS ARE NOT UNIFORM (71/2-51/4-81/2 ).RAIL HEIGHT IS 37 INCHES, RIM BEAM NOT BOLTED TO COLUMN, WHERE STRINGER SITS IN POCKET, SEE HUGH VOID. FOOTING STATUS UNKNOWN. WEST PORCH 5119 , FOOTING STATUS UNKNOWN, 2X8 JOISTS ARE SPANNED 10 FEET 11 INCHES. WITH FIRE CUTS ON BOTH ENDS, STRINGER ALONG BUILDING NOT BOLTED. RAIL HEIGHT IS 371/2 INCHES. SEE GAPS ON RISER TO TREADS. COLUMNS ARE BUTT JOINTED. WEST PORCH 5121-FOOTING STATUS UNKNOWN, 2X8 JOISTS ARE SPANNED 11 FEET, COLUMNS ARE BUTT JOINTED, RAIL HEIGHT IS 32 INCHES. MISSING BOLTS ON BEAM TO COLUMN. STRINGERS ALONG BUILDING NOT BOLTED. WEST PORCH 5123- FOOTING STATUS UNKNOWN, 1ST FLOOR OUT OF LEVEL. POOR DESIGN, RIM JOIST BUTTING COLUMN ,TOE NAILED ONLY !!!! RISERS 2ND TO 3RD ARE ROTTED. WHERE BEAM MEETS LEDGER BEAM NOT BOLTED. ACQUIRE A LICENSED ARCHITECT OR STRUCTURAL ENGINEER AND OBTAIN PERMIT FOR ALL REAR/SIDE PORCHES, TO REPLACE OR REPAIR. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | WEST ELEVATION - HIGH WEEDS, OVERGROWN VEGETATION. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
RATS | 5113/ 3N AND 1N: RATS AND RODENTS PROBLEM. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH RECENTLY BUILT, 6X6 COLUMN AT THIRD FLOOR TO ROOF SEVERLY TWISTED ( 3 TO 4 INCHES OUT OF PLUMB) AT LAP JOINT. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | OTHER THAN 5117 1NORTH UNABLE TO GAIN ENTRY TO APTS TO VERIFY OCCUPANCY AND DETECTORS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
RATS | 5113/ 3N AND 1N: RATS AND RODENTS PROBLEM. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
INSECTS | APT 5117 1 NORTH VISIBLE SIGNS OF BED BUGS. BUILDING -BED BUG INFESTATION THROUGHOUT. PROPERTY MUST BE EFFICTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | 5117 APT 1NORTH VERY DIRTY CARPETING. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | OTHER THAN 5117 1NORTH UNABLE TO GAIN ENTRY TO APTS TO VERIFY OCCUPANCY AND DETECTORS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH RECENTLY BUILT, 6X6 COLUMN AT THIRD FLOOR TO ROOF SEVERLY TWISTED ( 3 TO 4 INCHES OUT OF PLUMB) AT LAP JOINT. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED 2010-2014. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | 5113W/ APT. #2- BATHROOM SINK- BROKEN SINK PLUG. | 5113 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | 5113 W./ APT. #2- REAR ENTRANCE DOOR- BROKEN/MISSING LOCK SET. | 5113 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | 5113 W./APT. #2- TWO INTERIOR CLOSET DOORS,FIRST IN HALLWAY,SECOND IN MASTER BEDROOM,BROKEN DOORS . | 5113 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | 5113 W. / APT. #2- KITCHEN CABINET DOORS,BROKEN DOORS. | 5113 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILL ,WASHED OUT MORTAR | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | ADDITIONAL INFORMATION: ARRANGE INSPECTION,INTERIOR,PORCHES,NO ACCESS TO PORCH,REFUSAL | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS AND LEVELS - MISSING WINDOW SCREENS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR DOOR HARDWARE | FRONT BUILDING ENTRY DOOR AT 5115 W./ - DEFECTIVE LOCK. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION - SPALLING BRICKS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING , NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
HEAT UNIT ADEQUATELY | APARTMENT 1S-67.,APARTMENT 3S-63,APARTMENT 3N-65 | 5113 W WASHINGTON BLVD | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | 5117 APT 1NORTH VERY DIRTY CARPETING. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
INSECTS | APT 5117 1 NORTH VISIBLE SIGNS OF BED BUGS. BUILDING -BED BUG INFESTATION THROUGHOUT. PROPERTY MUST BE EFFICTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
DWELLING CLEAN AND SANITARY | 5117 APT 1NORTH VERY DIRTY CARPETING. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | 5115 AND 5113 ENTRANCE DOORS - BROKEN LATCHES. DON'T LOCK, | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING , NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS.ENTRY TO APT'S 5517/1S AND 5115/2N ; STAIRWAYS 5113,5115 AND 5117 ONLY. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
MICE/RODENTS | INTERIOR OF BUILDING - MICE INFESTATION. EVIDENT IN APT'S 5115/2N AND 5117/1S., PROFESSIONAL EXTERMINATOR TO ABATE MICE. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
INSECTS | BUILDING INFESTED WITH BED BUGS, INCLUDING APT. 5113 W./ APT. 2S. -BUILDING MUST BE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT BY EMPLOYING AN EXPERANCED EXTERMINATOR IN ABATMENT OF BED BUG INFESTATION. BUILDING DEP. WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATIONS INCLUDING COURTYARD,( FACE BRICK WALLS) - FRACTURES , LOOSE MORTAR AT VARIOUS LOCATIONS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS -MISSING OR TORN SCREENS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
CARPETING | STAIRWAYS 5113 AND 5117 - LOOSE OR TORN CARPETING. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | 5115 STAIRWAY - LOOSE TREADS AT VARIOUS LOCATIONS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
USE SANITARY REFUSE CONTAINERS | REAR ALLEY - OVER FILLED GARBAGE CONTAINERS, GARBAGE THROWN ONTO ALLEY WAY. RAT HARBORAGE. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING , NO ENTRY NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS. | 5113 W WASHINGTON BLVD | PERIODIC | FAILED | View |