Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | ALL ELEVATION - EXTERIOR WALL , WASHED OUT MORTAR AND SPALLING BRICKS.PERMIT REQUIRED FOR MASONRY WORK. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | EAST ELEVATION - REAR YARD EXCESSIVE TRASH AND DEBRIS THROUGH-OUT. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S I.D. SIGN MISSING. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | VARIOUS LOCATIONS - 2ND AND 3RD FLOOR WINDOW PANES, BROKEN. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 705 W./ HEATING ROOM - CARBON MONOXIDE DETECTOR MISSING. BL00831 | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 705 W./ SMOKE DETECTOR MISSING. BL00831 | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION - REAR PORCH - 6X6 COLUMNS FOUNDATION FOOTING STATUS UNKNOWN.COLUMN TO BEAM CONNECTIONS , LIGHT GAGE METAL STRAPS COLUMN SPLICE,MISSING BOLTS AND EXCESSIVE STAIR LENGHT. ALL WOOD COMPONENTS TOE- NAILED. AS SEEN FROM ALLEY. PERMIT REQUIRED FOR REPAIRS. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATION - EXTERIOR WALL , WASHED OUT MORTAR AND SPALLING BRICKS.EAST EXTERIOR WALL BRICKS MISSING AND LOOSE,WEST WALL BUCKLING OUT.[PERMIT FOR REPAIRS FOR MASONRY WORK].DANGEROUS CONDITION. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | EAST AND SOUTH ELEVATION; JUNK AND DEBRIS. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S I.D. SIGN MISSING. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | 2ND AND 3RD FLOOR WINDOW PANES; BROKEN. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | 705 W./ HEATING ROOM - CARBON MONOXIDE DETECTOR MISSING. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | 705 W./ REAR EXTERIOR DOOR- PAD LOCKED. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
NO KEY TO USE EXIT DOOR | 705 W./ REAR EXTERIOR DOOR- PAD LOCKED. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | POST OWNERSHIP ON BUILDING. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS; OPEN JOINTS AND CRACKED. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST BASEMENT RETAINING WALL; GUARD RAILS MISSING, | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY; BRICKS MISSING AND LOOSE. [DANGEROUS CONDITION] | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
CHIMNEY CAPPING | CHIMNEY CAPPING MISSING. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPAIR PORCH SYSTEM | 701 PORCH; UPRIGHT TWISTED AND OUT OF PLUMB,HAND RAILS AND GUARD RAILS LOOSE,GUARD RAILS PULLING AWAY FROM SUPPORTS,TREADS WOOD SPLIT AND BROKEN,NO FOOTINGS,LOOKOUTS TOE NAILED TO SUPPORTS,NAILS STICKING UP. 705 PORCH; STRINGER WOOD SPLIT,LOOKOUTS TOE NAILED TO SUPPORTS,6X6 UPRIGHT OVERCUT,NO FOOTINGS,HAND RAILS LOOSE,TREADS WOOD SPLIT,TREAD WINDERS BROKEN,LOOKOUT PULLING AWAY FROM FIRE CUTS AND NOT SEAL IN THE WALL.[SUBMIT PLANS AND PERMITS TO REPLACE PORCH SYSTEMS] | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 701 S KEDZIE AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 701 S KEDZIE AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 701 S KEDZIE AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 701 S KEDZIE AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 701 S KEDZIE AVE | COMPLAINT | CLOSED | View | |
REPAIR EXTERIOR WALL | REPAIR EXTERIOR WALL - NORTH AND WEST ELEVATIONS LINTELS SEVERELY RUSTED CAUSINIG DAMAGE TO SURROUNDING AND BRICK IS BOWING OUTWARD DANGEROUS AND HAZARDOUS.ALL ELEVATIONS BRICK SEVERE WASHED OUT MORTAR, BRICK DAMAGED CRACKED.SOUTH ELEVATION BOTH SOUTHWEST CORNER AND SOUTHEAST CORNER BRICK DAMAGED, LOOSE, SECTIONS MISSING AT PARAPET WALL. SOUTH ELEVATION UNFINISHED BRICK SEVERE WASHED OUT MORTAR. DANGEROUS AND HAZARDOUS.ALL ELEVATIONS BRICK BULGING OUTWARD OVER PUBLIC SIDEWALK.PLANS AND PERMITS REQUIRED FOR ALL MASONRY REPAIRS. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
VACANT BUILDING - REGISTER | VACANT BUILDING - INSURE | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
DEBRIS, EXCESSIVE | REMOVE ALL WEEDS, GARBAGE AND JUNK FROM AROUND PROPERTY ALL ELEVATIONS. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY DANGEROUS AND HAZARDOUS MISSING BRICKS (COLLASPED) COPING MISSING ATOP OF CHIMNEY.PLANS AND PERMITS REQUIRED FOR ALL MASONRY REPAIRS. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
VACANTBUILDING-REGISTER/SECURE | VACANT BUILDING - REGISTER | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR UNDER PORCH LARGE FLOOR OPENING FLOOR COVER BOARDS ROTTED WEAK, DANGEROUS AND HAZARDOUS, MISSING FALL PROTECTION GURADRAIL | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | BUILDING - NO ADDRESS POSTED. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | ALL ELEVATIONS WINDOWS BROKEN, DAMAGED, ROTTED, BOARDED. DANGEROUS AND HAZARDOUS. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
PROVIDE SIDEWALK SHED F/PROTCT | INSTALL SIDEWALK CANOPY NORTH AND WEST ELEVATIONS. OBTAIN PERMIT FROM DEPARTMENT OF TRANSPORTATION. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
POST OWNER INFO ON ABDN BLDG | VACANT BUILDING - OWNER/MANAGEMENT ID SIGN POSTED. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR, RESET | ALL EXTERIOR DOORS ROTTED, MISSING BOARDED UP. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPLACE D&H PORCH | REAR TWO - THREE STORY WOOD PORCH DANGEROUS AND HAZARDOUS ALL WOOD WATER DAMAGED ROTTING - COLUMNS ERECTED ON CONCRETE FOOTING ROOTING AS BASES. COLUMNS NOT ANCHORED AT BASES. COLUMNS OVER NOTCHED WITH FIRE CUTS AND BEAMS OCCURING AT SAME LOCATION. COLUMNS HAVE INADEQUATE HALF-LAP JOINTS WITH ONLY TWO BOLTS. BEAMS NAILED TO COULMNS. BEAMS NOT TIED BACK TO BUILDING STRUCTURE WALLS INSIDE BEAM POCKETS MISSING STRAPS OR ANCHORS. STRINGERS NAILED TO COLUMNS. STRINGERS INADEQUATELY SUPPORTED AT COLUMNS WITH WOOD BLOCKS. STRINGERS AT UPPER ENDS AND LOWER ENDS WITH NAILS. TREADS AND RISES WORN OUT, ROTTING, WEAK. GUARD RAIL SECTIONS FASTENED TO COLUMNS AND EXTERIOR WALLS WITH NAILS. RAILING SECTIONS ROTTING, MISSING PICKETS. PLANS AND PERMITS REQUIRED TO REPLACE TWO PORCHES. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
BUILDING IN DISREPAIR | BUILDING IN DESREPAIR WINDOWS, DOORS, INTERIOR WALLS, CEILINGS, ELECTRICAL, PLUMBING, ROOF, HVAC SYSTEMS, PLANS AND PERMITS REQUIRED FOR ALL NECESSARY REPAIRS. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | 705 W./ SMOKE DETECTOR MISSING. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
PRV CAST IRON COVER FOR BASIN | YARD AREA CATCH BASIN COVER; MISSING. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 1990 THRU 2013. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR | EXTERIOR DOORS AND FRAMES; RUSTED. | 701 S KEDZIE AVE | PERIODIC | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 701 S KEDZIE AVE | COMPLAINT | CLOSED | View |