Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE TO VERIFY DETECTORS OR COMPLAINT OF LEAKING ROOF ON SECOND FLOOR. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF BUILDING. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
PARAPET | EAST AND WEST PARAPETS HAVE LOOSE/MISSING MORTAR. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS, VARIOUS LOCATIONS, MISSING WINDOW SCREENS. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO REAR EXTERIOR ENTRY DOORS. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | RELOCATE DEFECTIVE AND IMPROPERLY INSTALLED POWER SERVICE AND RELOCATE METERS TO A MORE READILY ACCESSIBLE LOCATION. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR TWO STORY FRAME PORCH IS IN A DANGEROUS CONDITION, UNEVEN RISER HEIGHT BASEMENT TO GRADE. STRINGERS: GRADE TO FIRST FLOOR FIRE DAMAGED AND SPLIT, 1ST FLOOR TO 2ND FLOOR CRACKED STRINGERS ONLY BEARING APPROXIMATELY TWO INCHES ONTO SOLID SURFACE.. TREADS: WORN TREADS 1ST TO 2ND FLOOR, FIRE DAMAGED AND MISSING TREADS GRADE TO 1ST FLOOR. DECK: FIRST FLOOR FIRE DAMAGED TONGUE AND GROOVE DECKING, MISSING SECTIONS COVERED WITH SUBSTANDARD PLYWOOD, 2ND FLOOR WORN TONGUE AND GROOVE DECKING. STRUCTURE: BOTH MAIN SUPPORT COLUMNS ARE BOWED AWAY FROM BUILDING CAUSING LOOKOUT SUPPORT BEAMS TO PULL OUT OF SUPPORT POCKETS WITH APPROXIMATELY ONE INCH SURFACE BEARING. PORCH NEEDS TO BE TORN DOWN AND NEW PORCH BUILT IN ITS PLACE. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS TO BUILD NEW PORCH AT REAR. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | BASEMENT NORTH EXIT DOOR IS BROKEN | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
CONNECT GAS APPLIANCE TO VENT | FLUE PIPE FOR FURNACE AT BASEMENT SERVING 1ST FLOOR IS PITCHED DOWNWARD. FLUE PIPE FOR HOT WATER HEATER AT BASEMENT IS DISCONNECTED. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | FORCED AIR FURNACE AT BASEMENT IS PARTIALLY DISASSEMBLED AND INOPERABLE. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | NON LOAD BEARING PARTITIONS HAVE BEEN INSTALLED AT BASEMENT FORMING TWO BEDROOMS. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR AT BASEMENT | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CO DETECTOR AT BASEMENT | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
UNSANITARY CONDITIONS-ANIMALS | DOG FECES THROUGHOUT BASEMENT. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
PROVIDE HOT WATER TO FIXTURES | NO COLD WATER LAV, TOILET, AND TUB, AND KITCHEN SINK 1ST, AND 2ND FLOOR UNITS | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER LAV, TUB, AND KITCHEN SINK 1ST AND 2ND FLOOR UNITS. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
REMOVE STAGNANT WATER BSMT | REMOVE STANDING WATER IN BASEMENT. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 3435 W HARRISON ST | COMPLAINT | CLOSED | View | |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INTERIOR OF BUILDING. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER POSTING. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
PARAPET | EAST/WEST PARAPET HAS LOOSE/MISSING MORTAR. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH 2 STORY WOOD FRAMED PORCH HAS 6X6 LOCKOUTS PULLING AWAY FROM 6X6 SUPPORT COLUMNS MISSING JOIST HANGERS ROTTED 6X6 COLUMN AT EAST ELEVATION. 4X4 RESTING ON BRICKS. LOOSE HAND RAILS UNDERSIZED GUARD RAILS. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REPAIR/REPLACEMENT OF SOUTH 2 STORY WOOD FRAMED PORCH WILL REQUIRE PLANS AND PERMITS. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | PROVIDE ILLUMINATION TO FRONT AND REAR ENTRY DOORS INCLUDING ALL LEVELS AT EXTERIOR REAR PORCH AREA. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | NO HEAT ON 1ST AND 2ND FLOR UNITS, GAS TURNED OFF | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 1ST AND 2ND FLOOR UNITS USING ELECTRIC SPACE HEATERS | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST AND 2ND FLOOR MISSING SMOKE DETECTORS | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST AND 2ND FLOOR MISSING CO DETECTORS | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXABLE SUPPLY TO LAV, TOILET, AND KITCHEN FACUET AT THE 1ST AND 2ND FLOOR UNITS. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | APT.2,ROOM TEMPERATURES- LIVING ROOM 63F., KITCHEN 62F., BEDROOM61F. AT 1:03PM. HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED . | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | APT. 2, MISSING SMOKE DETECTOR. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
PROVIDE COLD WATER TO FICTURES | APT.2,COLD WATER- SHUT OFF. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
13-12-360 PROVIDE PERMIT TO CORRECT VIOLATIONS. | 3435 W HARRISON ST | COMPLAINT | FAILED | View | |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER LAV, TUB, AND KITCHEN SINK, 1ST AND 2ND FLOORS | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
PROVIDE PERMIT TO CORRECT VIOLATIONS. 13-12-360. | 3435 W HARRISON ST | COMPLAINT | FAILED | View | |
ADDITIONAL EXIT | ONLY ONE USABLE EGRESS DUE TO FIRE DAMAGE REAR PORCH | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
CHIMNEY | EAST CHIMNEY HAS LOOSE MORTAR AND SPALLING BRICKS. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE POWER SERVICE AND RELOCATE TO A READILY ACCESSIBLE LOCATION. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | APT.2- HOT WATER -SHUT OFF. | 3435 W HARRISON ST | COMPLAINT | FAILED | View |