Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 11:23 AM
PIN: 19134190350000
Property Address: 6142 S ROCKWELL ST
City - Zip: CHICAGO - 60629
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72071
2023 Tax District: 72014
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 43 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY 2ND FLOOR APT., BEDROOM TEMP. 65F. BASEMENT APT. BEDROOMS APT. 59F.HEATING SYSTEM SERVING 1ST AND 2ND FLOOR APT. IS ON AT TIME OF INSPECTION, HEAT IS INSUFFICIENT.BASEMENT APT. - NO HEATING UNIT PROVIDED. 6142 S ROCKWELL ST COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG 2ND FLOOR APT. HOT WATER SUPPLIED AT ONLY 80F.BASEMENT APT. HOT WATER SUPPLIED AT 67F. 6142 S ROCKWELL ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS REAR ENCLSED PORCH - MISSING SMOKE DETECTOR. 6142 S ROCKWELL ST COMPLAINT FAILED View
SAFE WORKING CONDITIONS BASEMENT APT. - NO HEATING UNIT PROVIDED. 6142 S ROCKWELL ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING OWNER'S ID. SIGN - INCOMPLETE INFORMATION POSTED : MISSING MAILING ADDRESS. 6142 S ROCKWELL ST COMPLAINT FAILED View
INSTALL EXTRA SMOKE DETECTORS REAR STAIRWAY - MISSING SMOKE DETECTOR. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE -SERVICE DOOR SMALLER THAN DOOR FRAME.NORTH ELEVATION - LOOSE SIDING. 6142 S ROCKWELL ST COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES ( INCLUDING PLUMBING AND ELECTRIC ) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. 6142 S ROCKWELL ST COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE THE BUILDING TO THE ORIGINAL STATE. ORIGINAL HEATING AND STORAGE BASEMENT SPACE HAS BEEN ALTERED IN TO A DWELLING UNIT. 6142 S ROCKWELL ST COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) EAST ELEVATION BRICK WORK OUT OF PLUMB, OUT OF LEVEL 6142 S ROCKWELL ST COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# INCOMPLETE MANAGEMENT SIGN 6142 S ROCKWELL ST COMPLAINT FAILED View
PARAPET & COPING SOUTH ELEVATION PARAPET SPALLING BRICKS 6142 S ROCKWELL ST COMPLAINT FAILED View
CIRCUIT ONE UNIT ONLY MIXED CIRCUIT 1ST FLOOR AND BASEMENT UNIT 6142 S ROCKWELL ST COMPLAINT FAILED View
DEFECTIVE POWER SERVICE NO POWER REAR OF 1ST UNIT 6142 S ROCKWELL ST COMPLAINT FAILED View
INSTALL ILLUMINATION REPAIR LIGHT FIXTURES AT ALL ENTRY AND HALLWAYS 6142 S ROCKWELL ST COMPLAINT FAILED View
DEFECTIVE OUTLETS DEFECTIVE OUTLET THROUGHOUT 1ST FLOOR AND BASEMENT UNITS 6142 S ROCKWELL ST COMPLAINT FAILED View
INSTALL COVERS INSTALL GLOBES FOR FIXTURES THROUGHOUT 1ST FLOOR AND BASEMENT. 6142 S ROCKWELL ST COMPLAINT FAILED View
INSECTS BED INFESTATION THROUGHOUT THE 1ST FLOOR APARTMENT. 6142 S ROCKWELL ST COMPLAINT FAILED View
DEFECTIVE OUTLETS 1ST FLOOR ... MOST OUTLETS AND LIGHT FIXTURES ARE INOPERABLE. 6142 S ROCKWELL ST COMPLAINT FAILED View
SAFE WORKING CONDITIONS 1ST FLOOR UNIT ... KITCHEN CABINETRY MISSING DOORS. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE 1ST FLOOR UNIT ... BATH TUB NEEDS CAULKING AT FLOOR AREA. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE 1ST FLOOR UNIT ... MISSING VINYL TILES. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPAIR EXTERIOR DOOR 1ST FLOOR UNIT ... REAR DOOR ... MISSING KNOB. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL FRONT ... MASONRY COLUMNS ARE OUT OF PLUMB. AREAS OF DISPLACED / SHIFTED BRICKWORK. PERMIT REQUIRED FOR REPAIRS. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION LIMESTONES ABOVE 2ND FLOOR WINDOWS ARE SHIFTING OUT.SOUTH ELEVATION - SPALLING BRICKS AND WASHED OUT MORTAR. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE - PEELING PAINT AND MISSING SHINGLES. 6142 S ROCKWELL ST COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 1ST FLOOR APT. - MISSING SMOKE DETECTOR. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPAIR/REPLACE SMOKE DETECTORS REAR PORCH, SMOKE DETECTOR - MISSING BATTERY. 6142 S ROCKWELL ST COMPLAINT FAILED View
ROACHES BUILDING INFESTED WITH ROACHES, INCLUDING 1ST FLOOR APT. 6142 S ROCKWELL ST COMPLAINT FAILED View
MICE/RODENTS BUILDING INFESTED WITH MICE, INCLUDING 1ST FLOOR. 6142 S ROCKWELL ST COMPLAINT FAILED View
MAINTAIN WINDOW 1ST FLOOR LIVINGROOM NORTH WINDOW LEAKS . 6142 S ROCKWELL ST COMPLAINT FAILED View
DEFECTIVE OUTLETS 1ST FLOOR APT. THRU OUT, SEVERAL OUTLETS AND LIGHT FIXTURES DO NOT HAVE ELECTRIC POWER. 6142 S ROCKWELL ST COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT 1ST FLOOR APT., BATHROOM WALLS AND CEILING - LOOSE PAINT; REAR ENCLOSED PORCH 1ST FLOOR WALL HAVE MILDEW. 6142 S ROCKWELL ST COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS REAR YARD - HIGH WEEDS. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH ELEVATION, BASEMENT WINDOW - BROKEN GLASS PANE. 6142 S ROCKWELL ST COMPLAINT FAILED View
REPAIR FLOOR 1ST FLOOR KITCHEN - TORN FLOOR TILES. 6142 S ROCKWELL ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION BASEMENT, FRONT INTERIOR STAIRWAY AND 2ND FLOOR APT. - NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. 6142 S ROCKWELL ST COMPLAINT FAILED View
LIGHT AND VENT BASEMENT REAR BEDROOM - NO WINDOW. 6142 S ROCKWELL ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION REFUSED ENTRY 6142 S ROCKWELL ST COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE INSPECTION FOR WORK PREVIOUSLY PERMITTED #100486270, 13-12-380 INSPECTION 6142 S ROCKWELL ST COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST (FRONT ) ELEVATION, ORNAMENT STONES ABOVE 2ND FLOOR ARE SHIFTING OUT, WALL SECTION ABOVE 2ND FLOOR WINDOW IS LEANING IN. (REPLACE WINDOW LINTELS UP TO 9'-5" IF RUSTED AND BENT). PLANS AND MASONRY PERMIT ARE REQUIRED TO REPAIR EXTERIOR WALLS AND REPLACE WINDOW LINTELS. 6142 S ROCKWELL ST COMPLAINT FAILED View
CHIMNEY CAPPING CHIMNEY - MISSING CONCRETE CAP. 6142 S ROCKWELL ST COMPLAINT FAILED View
PARAPET NORTH PARAPET WALL (WEST END) - SPALLING BRICKS. 6142 S ROCKWELL ST COMPLAINT FAILED View