Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | NO OWNERSHIP POSTED | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | FRONT FOYER DOOR BROKEN PANE | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
INT WALL/CEILING CHIP PLASTER | FRONT STAIRWELL AT 2ND WALLS BROKEN PLASTER | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY 2ND FLOOR UNIT | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
STOP SMOKE, NOXIOUS ODORS | BASEMENT SEWER ODOR | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
INSTALL HEAT APPLNCE FNDATION | BASEMENT - MECHANICAL CLOSET - WATER HEATER BEARS UPON CONCRETE FLOOR | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | UNVENTED GAS-FIRED WALL FURNACE AND RADIANT "WALL PLATE" USED TO HEAT UNIT.BOTH UNITS UNACCEPTABLE AS HEATING DEVICE. | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRICAL) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | BASEMENT CONVERTED TO DWELLING UNIT AND USING 1ST FLOOR REAR SUNROOM AS A NURSERY. SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE CONVERSION OF BASEMENT INTO A DWELLING UNIT AND SUNROOM INTO SLEEPING ROOM OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRS (GRADE TO BASEMENT) WIDTH OF STAIRS IS ONLY 28" WIDEINTERIOR STAIRS (GRADE TO 1ST FLOOR) DIFFERENT RISER HEIGHT CREATING TRIP HAZARD | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
REPAIR DOOR HARDWARE | BASEMENT - LOCK FOR FRONT ENTRY DOOR HAS BEEN NOTCHED INTO WALL BECAUSE THE ENTRY DOOR IS WIDER THAN THE WIDTH OF THE STAIRS; DIFFICULT TO OPERATE FROM INSIDE BASEMENT. | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT - CEILING HEIGHT IS 83 1/2" AND LESS IN SOME AREAS | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
CONNECT GAS APPLIANCE TO VENT | BASEMENT - WATER HEATER - FLUE IS NOT VENTED TO THE EXTERIOR; FUMES RE-ENTER BASEMENT UNIT | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT - LAUNDRY ROOM - CARBON MONOXIDE DETECTOR - MISSING | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | BASEMENT - LAUNDRY ROOM - EXPOSED WIRES AT JUNCTION BOX; COVER MISSING AT JUNCTION BOX AND WALL SWITCH | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | BASEMENT - REAR ENTRY - DEADBOLT LOCK MISSING | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | BASEMENT - LOCK FOR FRONT ENTRY DOOR HAS BEEN NOTCHED INTO WALL BECAUSE THE ENTRY DOOR IS WIDER THAN THE WIDTH OF THE STAIRS; DIFFICULT TO OPERATE FROM INSIDE BASEMENT; OBSTRUCTING EXITWAY.WEST ELEVATION - REAR GATE - CHAINED AND PADLOCKED | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
REPAIR BALCONY | 1ST FLOOR - BALCONY - LOOSE RAILS THRU-OUT | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | BASEMENT - MECHANICAL CLOSET - WATER HEATER LOCATED DIRECTLY UNDERNEATH INTERIOR STAIRS; DRYWALL MISSING. | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
HEATING PLANT ENCLOSURE | BASEMENT - MECHANICAL CLOSETS - WATER HEATER LOCATED DIRECTLY UNDERNEATH STAIRS FROM GRADE TO 1ST FLOOR - DRYWALL MISSING.FURNACE ROOM - DRYWALL MISSING AT WALLS, CEILINGS. | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | HALLWAY DOOR - GLASS PANE MISSING | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
RESET LOOSE FIXTURE | 1ST FLOOR APARTMENT - KITCHEN - WATER LEAKING AT SINK FAUCET. | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | BASEMENT - LAUNDRY ROOM - EXPOSED WIRES AT JUNCTION BOX | 8006 S BURNHAM AVE | COMPLAINT | FAILED | View |