Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
NO POSTED ADDRESS | BUILDING - NO ADDRESS POSTED ALONG ENTRANCES. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH ELEVATION - TWO STORY WOOD EXIT STAIR FROM GARAGE ROOF TOP ROTTED STINGERS, TREADS, RISERS, COLUMNS AND BEAMS AND JOISTS WORN, ROTTED. IMPROPER CONNECTIONS THROUGHOUT STAIR SYSTEM, DANGEOUS AND HAZARDOUS.PERMIT REQUIRED TO REPLACE WOOD STAIR.NOTE: GARAGE STAIR SYSTEM IS SECOND EXIT FOR SECOND FLOOR REAR RESIDENTS. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARD RAIL - MISSING ALONG GARAGE ROOF , CURRENTLY ROOF WALLS ONLY 18 INCHES. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF - GARAGE ROOF DAMAGED, STRUCTURE MAY BE UNSTABLE, CAUSED BY PARAPET WALL MISSING ON SOUTH ELEVATION, DANGEROUS AND HAZARDOUS.PLANS AND PERMITS REQUIRED FOR ALL ROOF AND ROOF STRUCTURE REPAIRS.NOTE: GARAGE ROOF IS SECOND PATH OF EXIT FOR SECOND FLOOR REAR RESIDENTS. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REPAIR EXTERIOR WALL - WEST ELEVATION DOOR LINTEL RUSTED WARPED.WEST ELEVATION CORNER UNDERSIDE ABOVE DOOR ROTTED WOOD.WEST ELEVATION PARAPET WALL MISSING COPING.WEST AND SOUTH ELEVATIONS LINTELS RUSTED.SOUTH ELEVATION SOUTHWEST CORNER STRESS CRACKS IN BRICK WALL.SOUTH ELEVATION STONE WATER MARK ABOVE SECOND FLOOR WASHED OUT MORTAR.SOUTH ELEVATION REAR ADDITION TO BUILDING STRUCTURE LEANING AND SEPERATING, SINKING LARGE JOINT ALONG CONNECTION OF BOTH BUILDINGS CRACKED DANGEROUS AND HAZARDOUS.SOUTH ELEVATION REAR STRUCTURE ADDITION LINTEL RUSTED AND WOOD WORN.SOUTH ELEVATION GARAGE PARAPET WALL MISSING, DAMAGED DANGEROUS AND HAZARDOUS.EAST ELEVATION GARAGE PARAPET WALL WASHED OUT MORTAR.PLANS AND PERMITS REQUIRED FOR ALL MASONRY REPAIRS.NOTE: GARAGE ROOF IS SECOND EXIT FOR FOR SECOND FLOOR REAR RESIDENTS. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | WEST EXTERIOR DOOR FRAME; BROKEN. SOUTH EXTERIOR DOOR FRAME; ROTTED. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 1990 THRU 2014. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS; OPEN JOINTS. NORTH ELEVATION WINDOW SILL STONE; BROKEN. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PARAPET | NORTH PARAPET WALL; CHIP AND LOOSE BRICKS,MORTAR MISSING. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH EXTERIOR WALL; MORTAR MISSING. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS; TORN OR MISSING. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SECTION OF GARAGE ALTER INTO APARTMENT,NO PLANS AND PERMITS ON FILE,RESTORE GARAGE BACK TO ORIGINAL STATE. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | GARAGE APARTMENT REMOVE PARTITION WALL,PLUMBING,ELECTRICAL INSTALLED WITHOUT PLANS AND PERMITS. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR / REBUILD SHED | GARAGE PARAPET WALL BUCKLING IN,LINTELS RUSTED AND SAGGING,OVERHEAD DOOR FRAME BROKEN,EXTERIOR WALL MORTAR MISSING,EAST EXTERIOR WALL BUCKLING OUT. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | NORTH ELEVATION2ND FLR.WINDOW FRAME AND SASH; ROTTED. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EAST ELEVATION 2ND FLR.EXTERIOR DOOR; DRYROTTED. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | EAST ELEVATION 2ND FLR.EXTERIOR DOOR; BURGLAR BARS. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | WEST ENTRANCE DOOR LINTEL AND WEST ELEVATION 2ND FLR.LINTEL; RUSTED AND SAGGING [PERMIT TO REPLACE]. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR COPING | WEST COPING STONES; MISSING. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH EXTERIOR STAIR; HANDRAILS AND PICKETS MISSING,NO FOOTINGS,STRINGER RUN TO LONG AND ROTTED,TREADS IMPROPER WIDTH,REPLACE 4X4S WITH 6X6S,4X4S ROTTED,STAIR SYSTEM UNSTABLE AND LEANING.[SUBMIT PLANS AND PERMITS TO REPLACE] | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | WEST INTERIOR STAIR NO SMOKE DETECTOR. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | WEST 2ND FLR.APARTMENT DOOR; NO PEEPHOLE. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | WEST INTERIOR STAIR; TREAD WINDER WEAK AND LOOSE. | 2659 S SPRINGFIELD AVE | COMPLAINT | FAILED | View |