The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN IS NOT POSTED. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS - WASHED OUT MORTAR, LOOSE BRICKS. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
CHIMNEY | WASHED OUT MORTAR. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH-WING WALLS - WASHED OUT MORTAR. /SOUTH AT WEST MISSING HANDRAIL. FRACTURED AND SPALLING TREADS. SOUTH AT EAST - METAL POSTS SUPPORTING THE 1ST LANDING ARE RESTED ON SOIL. LANDING AT (2) IS CANTILEVERED AND ENCLOSED - UNABLE TO VERIFY STRUCTURAL MEMBERS. STRINGERS ARE FLOATING AND NOT ATTACHED TO THE BUILDING. MISSING RISERS. LOOSE HAND AND GUARDRAILS. GUARDRAILS ARE ONLY 33 INCHES IN HEIGHT. PICKETS ARE SPACED GREATER THAN 4 INCHES APART. BUCKLED UP DECK BOARDS. PEELING PAINT. IMPROPER CONNECTIONS - MOST MEMBER ARE TOE NAILED TOGETHER AND ARE SEPARATING AT THE CONNECTIONS. PLANS AND PERMIT ARE REQUIRED FOR REPAIRS OR REPLACEMENT OF THE SOUTHEAST STAIR SYSTEM. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | NORTH - LINTELS SUPPORTING THE PLATFORM ABOVE THE STAIRS ARE RUSTED, SAGGING AND PEELING PAINT. PERMIT REQUIRED FOR REPAIRS. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | SOUTH AT BASEMENT STAIRWAY - SPALLING CONCRETE. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS WINDOWS AND REAR STORM DOOR AT (1) MISSING SCREENS. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH AT REAR - FRACTURED CONCRETE. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
INSTALL DEAD BOLT LOCK | APT. 1 - ENTRY DOOR - MISSING DEAD BOLT LOCK. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | APT. 1 - AND NORTH STAIRWAY - MISSING DETECTORS. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | APT. 2 - DETECTOR IS OUT OF SERVICE. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BASEMENT - NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | ATTIC- REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE ATTIC WITHOUT A PERMIT. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | SOUTH ELEVATIONS- HANDRAIL MISSING FROM GRADE TO BASEMENT. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | EAST ELEVATION- REAR PORCH STAIRS- PLYWOOD USED AS DECKING MATERIAL; BOLTS MISSING AT STRINGERS; RAIL HEIGHT IS ONLY 32 3/4', STAGNATE WATER AT 1ST FLR DECK AND LANDING, PERMIT REQUIRED FOR REPAIRS TO REAR PORCH/STAIRS. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
REPUTTY WINDOW PANES | SOUTH ELEVATION- WINDOW TRIM ROTTING. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | SOUTH ELEVATION- ATTIC WINDOW SILLS ROTTING. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
PROVIDE DEADLOCK FOR ENTRANCE | SOUTH ELEVATION- ATTIC- DEADBOLT LOCK MISSING AT REAR DOOR. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | NORTH ELEVATION- BASEMENT ATTIC- CRACKED, BROKEN WINDOW PANES. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
SERVICE WALK, PASSAGE, AREAWAY | NORTH ELEVATION- SERVICE WALK CRACKED AT NORTHEAST CORNER. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION- STEP FRACTURES IN EXTERIOR WALL. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
REMV OBSTR FROM DRAINAGE SYSTM | ATTIC- BATHROOM- TOILET IS CLOGGED. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | ATTIC- HOT WATER- SHUT OFF; NO HOT WATER PROVIDED. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
PROVIDE COLD WATER TO FICTURES | ATTIC- COLD WATER- SHUT OFF; NO COLD WATER PROVIDED. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
REPAIR DOOR, INT. | ATTIC- FRONT ENTRY DOOR- BROKEN AT HINGES; HANGING; UNSECURED. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
EXIT THROUGH BEDROOM/BATHROOM | ATTIC- REAR EXIT IS ACCESSIBLE ONLY THROUGH REAR BEDROOM. | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
PROVIDE | ALL ELEVATIONS- PEELING PAINT ON EXTERIOR SURFACES (SEC 7-28-060) | 5801 S ALBANY AVE | COMPLAINT | PASSED | View |
HEAT UNIT ADEQUATELY | 65 DEGREES THROUGHOUT. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | BOILER IS DISMANTLED, NO OTHER SYSTEM PRESENT. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING DETECTOR IN FURNACE ROOM. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING DETECTOR IN FURNACE ROOM AND 1TS FLOOR. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 5801 S ALBANY AVE | COMPLAINT | CLOSED | View | |
REPAIR WINDOW SILLS | SOUTH - ROTTED SILL AT (2). | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH AT BASEMENT (REAR) - BROWN PANE. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | ALL ELEVATIONS - MOST FRAMES WITH PEELING PAINT. SOUTH AT BASEMENT - MOST STORM WINDOW FRAMES ARE ROTTED. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING FIXTURES | APT. 1 - LIVING ROOM - MISSING CEILING LIGHT FIXTURE, EXPOSED WIRING. | 5801 S ALBANY AVE | COMPLAINT | FAILED | View |