The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | EXTERIOR WALLS-WASHED OUT MORTAR; OPEN JOINTS; SHIFTING BRICKS; FRACTURES; FIRE DAMAGED (CHARRED). | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR CORNICE | CORNICE-RUSTED THRU; MISSING SECTIONS; FIRE DAMAGED (CHARRED). | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIR SYSTEM-EAST STRINGER FROM (G) TO (B) IS FRACTURED AT MID-LANDING JOIST CONNECTION. MID-LANDING-JOISTS MISSING HANGERS. UNDERSIZED; 3 INCH X 3 INCH X 1/8 INCH, AND 6 INCH X 6 INCH X 1/8 INCH STEEL ANGLES SUPPORTING THE BEAM ARE UTILIZED IN LIEU OF 4 INCH X 8 INCH X 1/2 INCH STEEL ANGLES. RAILS-MISSING PICKETS. IMPROPER CONNECTIONS-MOST MEMBERS ARE ONLY TOE NAILED TOGETHER. ONLY PERMIT REQUIRED FOR REPAIRS. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL-MISSING. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | DOWNSPOUT-MISSING BOTTOM SECTION; DRAINING WATER ONTO THE STAIR SYSTEM AND SERVICE WALK OF THE ADJACENT PROPERTY. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FENCE-BROKEN, LOOSE CHAIN LINK FENCING; BENT POSTS; LEANING; MISSING TOP RAILS. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW PANES-MISSING, BOARDED UP. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOW SASHES-MISSING. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | PILES OF BROKEN CONCRETE. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | PLANS AND PERMIT NOT AVAILABLE FOR INSPECTOR REVIEW AT TIME OF INSPECTION. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR OR REPLACE | ELECTRICAL CONDUIT IS LOOSE, HANGING AND ONLY PROPPED UP WITH A 2X6 PIECE OF LUMBER (SEC. 7-28-060). | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
REMOVE | ELECTRICAL SERVICE POWER LINES ARE ATTACHED TO THE GUARDRAIL AND ARE ONLY 4 FEET TO 6 FEET ABOVE THE DECK BOARDS (SEC.7-28-060). | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | BUILDING ADDRESS IS NOT POSTED. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE FIRE DAMAGE REPAIRS TO THE APARTMENT. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | ACCUMULATION OF BROKEN GLASS. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | BUILDING REAR - DOWNSPOUT MISSING. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE-UNVERIFIED CONDITIONS. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | ACCUMULATION OF TRASH AND DEBRIS. | 1876 S KEDZIE AVE | COMPLAINT | FAILED | View |