The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR DOWNSPOUT | SR:801564322-EAST DOWN SPOUT MISSING | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
ADJUST GUTTER TO DRAIN ROOF | EAST GUTTERS FILLED WITH LEAVES | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
DEMO DEBRIS | UNDER FRONT DECK-CONSTRUCTION DEBRIS; WOOD FROM OLD PORCH | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNERS ID POSTED | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ONE STORY PORCH STRINGERS IMPROPERLY CUT AND SCABBED TOGETHER,FLOOR JOIST NOT PROPERLY SUPPORTED,LOW GUARD AND HAND RAILS,COLUMNS NOT PROPERLY SET ON EXISTING CONCRETE COLUMNS PERMIT REQUIRRED | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION VINNYL SIDDING MISSING SECTIONS ,LOOSE SECTIONS | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 1ST FLOOR ROOM TEMERATURE-61F.HEATING SYSTEM IS OFF AT TIME OF INSPECTION,NO HEAT PROVIDED. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | 1ST FLOOR,FURNACE- OUT OF SERVICE AT TIME OF INSPECTION.GAS SERVICE IS SHUT OFF. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | 1ST FLOOR MISSING SMOKE DETECTOR | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST FLOOR MISSING CARBON MONOXIDE DETECTOR. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | S.F.R TEMP WAS 65F AT 1:30 PM | 5444 S SEELEY AVE | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | FURNACE OUT OF SERVICE (PER TENANT). | 5444 S SEELEY AVE | COMPLAINT | CLOSED | View |
WINDOW REPAIR FOR AIR SEEPAGE | ALL ELEVATIONS - BROKEN WINDOW PANES. | 5444 S SEELEY AVE | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | BASEMENT AND ATTIC - MISSING SMOKE DETECTOR. | 5444 S SEELEY AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION - 1 STORY WOOD PORCH .1)LOOSE TREADS AND RISERS.2) 2X 6 OVER SPAN AND SAGGING.3) GUARD RAILS UNDER SIZED 32 "4) FRONT PORCH BEAM ROTTED AND SAGGING. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ENTANCE DOOR BROKEN AND MISSING HARDWARE. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | NO SMOKE DETECTOR AT 1ST FLOOR. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | NO CARBON MONOXIDE AT 1 ST FLOOR. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | MISSING HANDRAILS AT BASEMENT AND ATTIC. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | FRONT YARD AND REAR YARD DEBRIS AND REFUSE. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | WEST FENCE MISSING PICKETS AND GATE. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATION LOOSE AND MISSING SIDING. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | REAR SIDE WALK CRACK AND SINKING. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | LOOSE WIRE AND EXPOSE WIRE AT ATTIC AND BASEMENT | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
PROVIDE KIT SNK TO FAMILY UNIT | KITCHEN LOOSE FAUCET | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
STOP LEAKING WATER | BASEMENT WATER LINE LEAKING. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW BROKEN THROUGH OUT ALL ELEVATION. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
VACANT BUILDING - REGISTER | 5444 S SEELEY AVE | COMPLAINT | CLOSED | View | |
STOP/REMOVE NUISANCE | REAR YARD LARGE TREE DROPPING BERRIES ON ADJACENT YARD CREATING A NUISANCE | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | BROKEN WINDOW SOUTH,WEST BOARDED HALF OF WINDOW | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | HOT WATER SUPPLIED AT ONLY 60F. | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | S.F.R. - NO HOT WATER PROVIDED. | 5444 S SEELEY AVE | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | BASEMENT AND ATTIC - MISSING CARBON MONOXIDE DETECTORS. | 5444 S SEELEY AVE | COMPLAINT | CLOSED | View |
PROVIDE HOT WATER TO FIXTURES | NO HOT WATER IN BUILDING . | 5444 S SEELEY AVE | COMPLAINT | FAILED | View |