The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR FLOOR | FRONT BEDROOM FLOOR,HOLE AT RADIATOR PIPING.LOOSE AND MISSING SECTIONS OF TILE IN HALLWAY. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | EVIDENCE OF ROOF LEAKS IN 2ND FLOOR APARTMENTS AT 1511 E. 73RD AND 7333 S. BLACKSTONE. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCHES,BROKEN TREADS,BROKEN AND MISSING PICKETS,GUARDRAILS ONLY 36INCHES HIGH, FOOTINGS ON SIDEWALK, OBTAIN PERMIT BEFORE MAKING REPAIRS. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | REAR ENTRY DOOR SPLIT PANEL. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | 7337 REAR DOOR BROKEN FRAME. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | DINING ROOM AND CLOSET, WATER DAMAGED CEILINGS. 7337 2ND FLOOR KITCHEN CEILING PEELING PAINT. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | 7337 MISSING WINDOW SCREENS. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | 2ND FLOOR APARTMENT, EVIDENCE OF MICE KITCHEN AND BATHROOM. 7337 2ND FLOOR ROACH INFESTED. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
FLOOR, KIT & BATH NON-ABSORB | 7337 2ND FLOOR KITCHEN AND BATHROOM MISSING SECTIONS OF FLOOR TILE. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | 7333 2ND FLOOR BEDROOM OUTLET BROKEN COVER. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | 7337 2ND FLOOR, LIVING ROOM CEILING LIGHT FIXTURE BROKEN. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FLUSH DEVICE | 7337 2ND FLOOR BATHROOM TOILET BROKEN FLUSH DEVICE. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | WINDOW SILLS-WORN; ROTTED. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | WATER LEAKING INTO APARTMENTS-VISIBLE WATER DAMAGE / STAINS. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR PORCHES (3)-(7333 S.) EDGE BEAMS ARE SEPERATING AT THE 4X4 POST CONNECTIONS. OVERCUT STRINGERS. ONLY 34 INCH HEIGHT GUARDRAILS. HANDRAILS FROM (1) TO (2) ONLY RANGE FROM 23 -30 INCHES IN HEIGHT. MOST MEMBERS ARE ONLY TOE NAILED TOGETHER AT THE CONNECTIONS. PLANS AND PERMIT REQUIRED FOR REPAIRS. (7337 S.) 1ST MID-LANDING IS SEPERATING FROM THE EDGE BEAM AND IS PITCHED DOWNWARD. FLIGHTS ARE NOTICEABLY SHIFT AND ARE PITCHED DOWNWARD TOWARD SOUTH. FRACTURED STRINGERS. OPEN BEAM POCKETS. GUARDRAILS HEIGHTS RANGE FROM 32 - 45 INCHES AND NOTICEABLY SHIFT UPON LOAD. MOST MEMBERS ARE ONLY TOE NAILED TOGETHER WITH SEPERATION AT THE CONNECTIONS. DANGEROUS AND HAZARDOUS CONDITIONS. PLANS AND PERMIT REQUIRED FOR PORCH REPLACEMENT. (1511 E.) ROTTED S/W COLUMN. COLUMNS ARE ONLY TOE NAILED TOGETHER AT THE BUTT JOINTS. ROTTED EDGE BEAMS ARE SEPERATING AT THE COLUMNS. ROTTED DECK JOISTS. OVERCUT STRINGERS. GUARDRAIL HEIGHTS RANGE FROM 32 - 45 INCHES AND NOTICEABLY SHIFT UPON LOAD. MOST MEMBERS ARE ONLY TOE NAILED TOGETHER AND SEPERATING AT THE CONNECTIONS. DANGEROUS AND HAZARDOUS CONDITIONS. PLANS AND PERMIT REQUIRED FOR PORCH REPLACEMENT. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | CEILINGS / WALLS-WATER DAMAGE; STAINS; PEELING PAINT. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW SASH | WINDOW SASHES-WORN; ROTTED. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES-WORN; ROTTED. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
INSECTS | BUILDING INTERIOR-BEDBUG INFESTATION THROUGHOUT. PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BEDBUGS THROUGHOUT BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BEDBUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | (BASEMENT) AT 1509 E & 7337 S ) FLOOR JOISTS ROTTED FRACTURED AND WATER DAMAGED SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS DANGEROUS AND HAZARDOUS CONDITIONS | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | (WEST ELEVATION) EXTERIOR WALL-BRICKS ARE SHIFTING OUTWARD ADJACENT THE 7337 S FRONT ENTRANCE OBTAIN PERMIT FOR REPAIRS | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | (WEST AND NORTH ELEVATIONS) WINDOW LINTEL SEVERAL ARE RUSTED THROUGH AND SAGGING OBTAIN PERMIT FOR LINTEL REPLACEMENT | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | (BASEMENT)EXPOSED AND ALTERED WIRING OBTAIN PERMIT FOR REPAIRS | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | WEST, NORTH AND EAST ELEVATION LINTELS - RUSTED AND DEFLECTING, SOME LINTELS OVER 6 FEET IN LENGTH, PLANS AND MASONRY PERMIT REQUIRED. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | REAR SERVICE WALK - BUCKLED, FRACTURED AND MISSING SECTIONS OF CONCRETE, TRIP HAZARD. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | FRONT FOYER WALLS WITH WOOD PANELING, NO FIRE RATING. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | SOME APARTMENT ENTRY DOORS ARE MISSING PEEP HOLES. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
NO POSTED ADDRESS | LABEL ALL APARTMENT ENTRY DOORS WITH UNIT NUMBERS. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
ROACHES | 7333 APARTMENT 2 AND ENTIRE BUILDING - ROACH INFESTATION. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR DOOR FRAME, MULLION | 7333 FRONT FOYER DOOR WILL NO CLOSE ENTIRELY. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | 7333 FRONT ENTRY DOOR MISSING LOCKSET, DANGEROUS AND HAZARDOUS TO TENANTS, | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO ENTRY TO MOST DWELLING UNITS, UNVERIFIED DETECTORS AND CONDITIONS. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | 1ST FLOOR WINDOWS ROTTED WINDOW FRAMES. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
INSECTS | BUILDING - BED BUG INFESTATION THROUGHOUT. PROPERTYMUSTBE EFFECTIVELY TREATED TO EXTERMINATE BED BUGS THROUGHOUT,BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BED BUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 7333 S BLACKSTONE AVE | COMPLAINT | FAILED | View |