PIN: 16232120080000
Property Address: 1319 S SPAULDING AVE
City - Zip: CHICAGO - 60623
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77091
2023 Tax District: 77113
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
REPAIR PORCH SYSTEM NEW REAR PORCH - UNDER CONSTRUCTION. FOOTINGS ARE INADEQUATE, 6X6 COLUMNS ARE SEVERALLY OUT OF PLUMB. MIDLANDING DOUBLE RIM JOIST ARE NOT IN BEAM POCKET. 1319 S SPAULDING AVE PERMIT PASSED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMIT ARE NOT AVAILABLE ON SITE FOR INSPECTORS REVIEW AT TIME OF INSPECTION. 1319 S SPAULDING AVE PERMIT PASSED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED FOR 2006 1319 S SPAULDING AVE COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# NO OWNER ID SIGN POSTED 1319 S SPAULDING AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR PLANS AND PERMIT ARE NOT AVAILABLE ON SITE FOR INSPECTORS REVIEW AT TIME OF INSPECTION 1319 S SPAULDING AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM NEW REAR PORCH UNDER CONSTRUCTION FOOTINGS ARE INADEQUATE 6X6 COLUMNS SEVERELY OUT OF PLUMB MIDLANDING DOUBLE RIM JOISTS ARE NOT IN BEAM POCKET 1319 S SPAULDING AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION UNABLE TO VERIFY DETECTORS OCCUPANCY 1319 S SPAULDING AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM EAST ELEVATION, REAR PORCH: STRUCTURAL COLUMN MISSING FROM GRADE TO 3RD FLOOR CEILING (SHOWN ON PLANS); DIFFERENT RISER HEIGHTS FROM 1ST TO 2ND FLOOR; STRINGER FROM 2ND TO 3RD FLOOR IS PITCHED EXCESSIVELY; DECK BOARDS ON 3RD FLOOR ARE IMPROPERLY SPLICED WITH INADEQUATE SUPPORT UNDERNEATH SPLICE JOINTS; LEDGER BOARD ON 1ST FLOOR IS CUT 6" TOO SHORT-DOES NOT EXTEND FULL LENGTH OF PORCH; INADEQUATE SPLICE JOINTS AT COLUMNS ON 3RD FLOOR; 8 INCH CONCRETE PIERS DRAWN ON PLANS ARE MISSING; PERMIT #100116689, ISSUED 060906; SUBMIT PLAN REVISIONS FOR PERMIT APPROVAL OR BUILD PORCH PER APPROVED PLANS; PORCH INSPECTION-FAILED 1319 S SPAULDING AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR FRONT OF BUILDING / EXTERIOR CONCRETE STAIRS - CRACKEDM WITH LARGE GAPS. BROKEN TREAD. 1319 S SPAULDING AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER BASEMENT WALL THRU-OUT COVER WITH BLACK MILDREW. 1319 S SPAULDING AVE COMPLAINT FAILED View
DWELLING CLEAN AND SANITARY BASEMENT WALLS AND CEILING WATER DAMAGE. 1319 S SPAULDING AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER BASEMENT WALL THRU-OUT COVER WITH BLACK MILDREW. 1319 S SPAULDING AVE COMPLAINT CLOSED View
DWELLING CLEAN AND SANITARY BASEMENT WALLS AND CEILING WATER DAMAGE. 1319 S SPAULDING AVE COMPLAINT CLOSED View
NO POSTED ADDRESS NO ADDRESS POSTED 1319 S SPAULDING AVE COMPLAINT PASSED View