The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ACCESS TO ROOF | 7350 N SHERIDAN RD | PERIODIC | FAILED | View | |
OPEN TYPE VIOLATION | REPAIR ALARM BELL PER A17.1-1996 RULE 211.1 ELEVATORS 2 AND 3. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | REPAIR TELEPHONE PER A17.1-1996 RULE 211.1 ELEVATOR #1. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | PROVIDE A-B-C RATED FIRE EXTINGUISHER IN ELEVATOR MACHINE ROOM PER A17.1-1996 RULE 1206.1H. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | INSTALL COVER ON SUMP PUMP LOCATED IN ELEVATOR PIT. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | 110V DISCONNECTS FOR CARS 1 AND 2 ARE MIS-NUMBERED, CORRECT SAME. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | IDENTIFY EACH ELEVATOR AT CAR OPERATIONS PANELS PER A17.1B-1998 RULE 211.9. 18-30-010, 13-20-120. EV006178. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | CLEAN ELEVATOR MACHINE ROOM NOT TO BE USED FOR STORAGE PER A17-1996 RULE 1206.2B. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR MALFUNCTIONING DOOR RESTRICTORS-ALL 3 ELEVATORS | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | CLEAN ELEVATOR PITS, CAR TOPS AND HOISTWAYS (HEADERS,SILLS, ETC.)-ALL 3 ELEVATORS. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | IDENTIFY ALL 3 ELEVATORS AT CAR OPERATING PANELS AND ALL LANDING DOOR FRAMES. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR MALFUNCTIONING EMERGENCY CAB LIGHTING-#2 WEST ELEVATOR. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROGRAM EMERGENCY COMMUNICATION (PHONE)TO OPERATE PROPERLY-#1 EAST AND #2 WEST ELEVATORS. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR FIRE SERVICE-CAR LANDS AT BASEMENT ON PHASE 1 COMMAND-#3 SERVICE ELEVATOR. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
ARRANGE FOR INSPECTION | CONTACT INSPECTOR PULLEN #651 312-743-3562. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | SHOW PROOF OF COMPLIANCE WITH SECTION 8.6.5.8 OF A17.1 - 2007 (BULKHEAD REQUIREMENTS). ALL 3 ELEVATORS. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR MALFUNCTIONING DOOR RESTRICTORS. ALL 3 ELEVATORS. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | CLEAN ELEVATOR PITS. ALL 3 ELEVATORS. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PERFORM CATEGORY 5 TEST. TAG AND DOCUMENT AS REQUIRED. ALL 3 ELEVATORS. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR EMERGENCY CAB LIGHTS/ALARM BELL CIRCUIT. ELEVATOR 2. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE A DEDICATED SOURCE OF POWER FOR DOOR DETECTORS. NOT TO BE POWERED BY CAB LIGHT CIRCUIT. ELEVATORS 2 AND 3. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE A DEDICATED SOURCE OF POWER FOR "WONDER GUARD" SECURITY SYSTEM. NOT TO BE POWERED BY CAB LIGHTING CIRCUIT. ALL ELEVATORS. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PROVIDE WORKING PIT LIGHTS. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | PIPE AND WIRE BOTTOM LIMIT PROPERLY. ELEVATOR #1. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | REPAIR MALFUNCTIONING DOOR RESTRICTOR-CAR #1 | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | PREFORM ANNUAL PRESSURE RELIEF AND HYDRAULIC SYSTEM TEST PER A17-1A-1997 RULE 1005.2A ALL ELEVATORS. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
OPEN TYPE VIOLATION | REPAIR DOOR RESTRICTOR PER A17.1A-1997 RULE 111.5 ELEVATOR #2. | 7350 N SHERIDAN RD | PERIODIC | PASSED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | WORKING EMERGENCY CAB LIGHT/ALARM BELL NOT WORKING ON CARS 1 AND 3. REPAIR SAME. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ALL ELEVATORS: WORKING DOOR RESTRICTORS REQUIRED. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ALL ELEVATORS: REPAIR FIRE SERVICE 1)WORKING CALL CANCEL BUTTONS REQUIRED. 2)FIRE SERVICE JEWEL MUST ILLUMINATE ON PHASE 1 3)CAR CALLS MUST BE ILLUMINATED WHEN CALL IS REGISTERED. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | 3 FIRE SERVICE KEYS REQUIRED IN FIREMAN'S KEY BOX FOR CARS 1 AND 2. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | CERTIFICATE FRAME REQUIRED IN CARS 2 AND 3. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ELEVATOR 3: REPAIR FIRE SERVICE 1)WORKING CALL CANCEL BUTTONS REQUIRED. 2)FIRE SERVICE JEWEL MUST ILLUMINATE ON PHASE 1 3)CAR CALLS MUST BE ILLUMINATED WHEN CALL IS REGISTERED.(FIRST CITED ON 4/5/23) | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | WORKING EMERGENCY CAB LIGHT/ALARM BELL NOT WORKING ON CAR 3. REPAIR SAME.(FIRST CITED ON 4/5/23) | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ALL ELEVATORS: WORKING DOOR RESTRICTORS REQUIRED.(FIRST CITED ON 4/5/23) | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ALL ELEVATORS: REPAIR NON WORKING POSITION INDICATORS AND DIRECTION ARROWS. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ALL ELEVATORS; CLEAN PITS,CARTOPS,DIVIDER BEAMS, AND HEADERS | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |
MAINTAIN OR REPAIR HYDRO ELEVA | ALL ELEVATORS: CATEGORY 1 TEST OVERDUE. TAG AND DOCUMENT AS REQUIRED. | 7350 N SHERIDAN RD | PERIODIC | FAILED | View |