The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
UNAPPROVED CORDS | REMOVE EXTENSION CORDS NEAR THE FURNACE AREA, BEHIND ALL THE COOLER, ABOVE THE DROP CEILING AREAS SPLICED TO LIGHT FIXTURES, NEAR THE BASEMENT STAIRS. REMOVE THE ROMEX ABOVE THE DROP CEILING POWERING THE LIGHT FIXTURES AND OTHER VARIOUS PLACES THROUGHOUT THE STORE AREA. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PROVIDE | NO MIXING VALVE AT LAVATORIES OR HAND SINK. INSTALL AT ALL REQUIRED LOCATIONS. (18-29-607.1.1) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PANEL SCHEDULES | MISSING LABELS ON THE PANELS IN THE BASEMENT AREA. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
BOND AROUND FITTINGS | MISSING COLD WATER GROUND TO THE SERVICE. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | NO DISCHARGE PIPE ON HOT WATER TANK IN REAR STORAGE AREA. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
VENT SYSTEM TO PRVNT BACK PRES | NO VENT ON LAVATORY IN REAR. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REMV OBSTR FROM DRAINAGE SYSTM | STANDING WATER IN BASEMENT FROM CONDENSATE LINE. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
FIRE EXTNGSHR RECHARGE & TAG | FIRE EXTINGUISHERS WITH OUTDATED TAGS (FROM JAN 2018) DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR OR REPLACE | REAR BASEMENT DOOR PADLOCKED DURING BUSINESS HOURS. (15-4-870) DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR UNIT-NO SMOKE DETECTORS, FRONT OR REAR STIARWELLS- NO SMOKE DETECTORS. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | NO FURNANCE OR BOILER IN THIS BUILDING 42 DEGREES IN 2ND FLOOR APARTMENT. INSTALL A HEAT PRODUCING APPLIANCE IN THE 2ND FLOOR APARTMENT. TENANT-MAI CARROLL (312) 285-8178 2ND FLOOR. | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
HEAT HABITABLE ROOM | NO FURNANCE OR BOILER IN THE BUILDING. 1ST FLOOR IS A WIP STOVE. 2ND FLOOR PCCUPIED APARTMENT. ADULT WOMEN AND DISABLED 12 YEAR OLD BOY. 42 DEGREES. | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 2ND FLOOR TENANT USING GAS STOVE AS PRIMARY HEAT SOURCE. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR UNIT - NO CARBON MONOXIDE DETECTORS. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO 2ND FLOOR RESIDENTIAL UNIT. ENTRY WAS MADE TO DORA FOOD MART ONLY. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER'S MANAGEMENT SIGN. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EAST EXTERIOR MASONRY WALL STRESS FRACTURE AT EAST ELEVATION. SPALLING BRICK AND WASHED OUT MORTAR JOINTS AT WEST ELEVATION. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR FENCE | PLYWOOD USED AT FENCE AT REAR WHICH IS LEANING AND OUT OF PLUMB. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE OVER HEAD DOOR AT EAST ELEVATION LEANING INWARD AND IN NEED OF REPAIR. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
FIRE DAMAGE, SINGED,SOOT | WEST INTERIOR WALL TOWARD FRONT OF STORE FIRE DAMAGE, LOOK ABOVE DROP CEILING. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | EAST MARKED EXIT BLOCKED BY COOLER. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PROVIDE | VARIOUS AISLES REDUCED AS FOLLOWS: 18", 20", 23", & 28". (15-4-880 & 15-4-900) DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
1-HR HEATING PLANT ENCLOSURE | HEATING PLANT AT REAR ENCLOSED IN WOOD PANELING WITH EXPOSED WOODEN JOISTS. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PROVIDE | EXPOSED LATH AND WOODEN JOISTS AT 1ST FLOOR COMMERCIAL SPACE CEILING BELOW RESIDENTIAL UNIT. (13-56-280) DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTOR IN BASEMENT AND 1ST FLOOR COMMERCIAL SPACE. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR IN BASEMENT AND 1ST FLOOR COMMERCIAL SPACE. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | INTERIOR DOOR LEADING TO BASEMENT BLOCKED BY COOLER AND REDUCED TO 15". BASEMENT DOOR OPENING IS ONLY 31". THE DOOR BEHIND COUNTER EMPLOYEE AREA IS ONLY 22". MINIMUM OF 36" DOOR REQUIRED. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR FLOOR | ENTIRE FLOORING SYSTEM IS WEAK AND SPONGY. THERE IS DEFLECTION UNDER LIVE LOAD. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PROVIDE | REMOVE DRYWALL AT BASEMENT CEILING TO FURTHER INSPECT STRUCTURAL STABILITY OF THE 1ST FLOOR. (13-196-030) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | SUBMIT STRUCTURAL ENGINEER'S REPORT FOR THE ENTIRE FLOORING SYSTEM AT 1ST FLOOR COMMERCIAL SPACE ONCE THE DRYWALL IS REMOVED AT BASEMENT CEILING. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
STRUCTURAL MEMBER, PIER BLOCK | REPAIR/REPLACE STRUCTURAL COMPONENTS ACCORDING TO THE STRUCTURAL ENGINEER'S REPORT. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMITS FOR THE FOLLOWING: 1. REPAIRS MADE FOR THE FLOORING SYSTEM ACCORDING TO STRUCTURAL ENGINEER'S REPORT. 2. INCORRECT RISER HEIGHT FOR PLATFORM BEHIND COUNTER EMPLOYEE AREA (13" RISER HEIGHT). 3. FIRE SEPARATION AT BASEMENT AND 1ST FLOOR CEILING. 4. INTERIOR STAIRS FROM GRADE TO BASEMENT. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRS FROM GRADE TO BASEMENT - FRACTURED STRINGER AND TREADS, MISSING 1ST TREAD AND BASEMENT LEVEL. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
DWELLING CLEAN AND SANITARY | MOLD LIKE SUBSTANCE AT BASEMENT CEILING - UNSANITARY. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
NON COMBUSTIBLE STAIRS | WOOD PANELING AT UNDERSIDE OF STAIRWELL FROM 1ST TO 2ND FLOOR - FIRE HAZARD. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BASEMENT CEILING REQUIRED 1-HOUR FIRE ENVELOPE. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
VENT SYSTEM TO PRVNT BACK PRES | NO VENT ON HAND SINK IN REAR. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE ALL UNAPPROVED FLEXIBLE WATER SUPPLY LINES AT TOILET, LAVATORY, LAUNDRY TUB AND HAND SINK AND AT ALL LOCATIONS AND THROUGHOUT PREMISE. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE ALL UNAPPROVED PVC WASTE AND VENT PIPING AT LAVATORY AND LAUNDRY TUB AND THROUGHOUT PREMISES. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
REMOVE | REMOVE ALL UNAPPROVED FERNCO COUPLINGS IN BASEMENT AND THROUGHOUT PREMISES. (18-29-705.12) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE UNAPPROVED PVC WASTE PIPING AT HAND SINK IN REAR OF STORE AND THROUGHOUT PREMISES. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PROVIDE OPEN FRONT TOILET SEAT | NO COMMERCIAL TOILET SEAT AT BATHROOM. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PRV FLUE FOR HOT WATER HEATER | FLUE PIPE IN BASEMENT NOT PITCHED PROPERLY AND RUSTED THROUGH, ALLOWING CARBON MONOXIDE TO ESCAPE. DANGEROUS AND HAZARDOUS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
EXPOSE FOR INSPECT APPROVAL | EXPOSE ALL UNAPPROVED PVC UNDERGROUND PIPING FOR INSPECTION. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
INSTALL TRAP,WASTE,VENT PIPES | PROVIDE PROPER DRAIN FOR CONDENSATE LINE IN BASEMENT. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
PROPER MATERIAL FOR HSE DRAIN | REMOVE ALL UNAPPROVED PVC UNDERGROUND PIPING USED FOR BUILDING DRAIN. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN LICENSED PLUMBER FOR VIOLATIONS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
OBTN PERMIT FOR PLUMBING WORK | OBTAIN PLUMBING PERMIT BEFORE WORK COMMENCES. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | LIGHTS MISSING ON REAR, SIDE AND RESIDENTIAL ENTRY DOOR. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
INSTALL COVERS | COVERS NOT SUPPORTED PROPERLY ON THE FRONT ENTRY LIGHTS. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
ABANDONED EQUIPMENT | REMOVE ALL ABANDONED EQUIPMENT, WIRING AND PIPING IN THE BASEMENT AREA. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
UNAPPROVED EM | EXIT SIGNS ARE PLASTIC THROUGHOUT THE ENTIRE STORE. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
NEED CEILING TILES REMOVED FOR A THOROUGH INSPECTION OF THE CEILING. (13-12-170) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View | |
RESTORE EXIT AND EM | RESTORE ALL THE EM LIGHTS TO WORKING CONDITION. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
SECURE RACEWAY | PIPES IN THE BASEMENT ARE NOT SUPPORTED PROPERLY. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
EXPOSED WIRING | EXPOSED WIRING THROUGHOUT THE DROP CEILING, VARIOUS LOCATIONS IN THE BASEMENT, IN THE REAR OF THE STORE AREA NEAR THE FRUIT AND VEGETABLE SIGN AND OTHER LOCATIONS THROUGHOUT THE STORE AREA. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | LIGHTS MISSING COVERS THROUGHOUT THE CEILING AND BROKEN LIGHTS THROUGHOUT THE BASEMENT AREA. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
DEFECTIVE DISTRIBUTION | PANELS MISSING CIRCUIT BREAKERS OR FILLERS IN THE PANELS. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
INSTALL COVERS | OPEN BOXES THROUGHOUT THE BASEMENT, BEHIND THE COOLER IN THE STORE AREA, PANELS MISSING COVERS, ON RECEPTACLES NEAR THE FRONT DOOR AND VARIOUS OTHER LOCATIONS THROUGHOUT THE STORE AREA. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
INSTALL GFCI'S | MISSING GFCI RECEPTACLES IN THE BASEMENT AREA AND IN THE BATHROOM AREA OF THE STORE. | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAYS | WIRING LAYING ON THE CEILING GRID, FREE AIR WIRING IN THE BASEMENT, PIPES NOT CONNECTED TO BOXES OR THE LIGHT FIXTURES IN THE BASEMENT AND IN OTHER VARIOUS PLACES THROUGHOUT THE STORE AREA. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
SUPPORT FIXTURES | LIGHTS NOT SUPPORTED TO THE BOXES PROPERLY IN THE BASEMENT AREA. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
SUPPORT OUTLET AND BOX | BOXES NOT SUPPORTED TO THE CEILING PROPERLY IN THE BASEMENT AREA. (DANGEROUS AND HAZARDOUS) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View |
OBTAIN PERMIT TO CORRECT ELECTRICAL VIOLATIONS. (13-12-360) | 5401 W AUGUSTA BLVD | COMPLAINT | PASSED | View | |
REPAIR EXTERIOR WALL | EAST - STEP FRACTURES AT EXTERIOR WALLS | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR FENCE | PLYWOOD USED AS FENCING MATERIAL; LEAING | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | COMPLAINANT NOT HOME AT TIME OF INSPECTION; NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, BASEMENT, REAR PREMISES, STOREFRONT, ENCLOSED REAR PORCH, AND SPECIFICALLY 2ND FLOOR UNIT FOR COMPLAINT OF MISSING DETECTORS, MICE, FOREIGN SUBSTANCE, AND LEAKS, AND MISSING DOORBELLS AND LOCKS. UNVERIFIED DETECTORS AND CONDITIONS. | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - PAINT PEELING AT EAVES; WINDOWS & OVERHEAD DOORS ARE BOARDED; ROTTING TRIM AROUND OVERHEAD DOOR. | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |
REPAIR SCREENS | WINDOW SCREENS - TORN AND/OR MISSING | 5401 W AUGUSTA BLVD | COMPLAINT | FAILED | View |