Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SUBMIT FOR APPROVAL PLANS | 6006 S MORGAN ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 6006 S MORGAN ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 6006 S MORGAN ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 6006 S MORGAN ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 6006 S MORGAN ST | COMPLAINT | CLOSED | View | |
REPAIR ROOF | ROOF SHINGLE HANGING AND MISSING. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | GUTTER AND DOWNSPOUT MISSING. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | LOOSE METER FITTING,NEEDS SUPPORT | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR ROOF | ROOF - LOOSE , BROKEN , BULGING , AND MISSING ROOFING MATERIAL - LEAKING. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | ALL ELEVATIONS THROUGHOUT - WALLS - DETERIORATED , DILAPITATED , BROKEN , AND MISSING SIDING / SHEATHING WITH HOLES. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR EAVES | ALL ELEVATIONS - EAVES - BROKEN , LOOSE , ROTTED , FALLING , AND MISSING SECTIONS. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT 1 STORY EXTERIOR PORCH - COLUMNS ERECTED ON CONCRETE BASES AND SOIL - FOUNDATION STATUS UNKNOWN. BEAMS ONLY NAILED TO COLUMNS . DECK JOISTS , MULTIPLE DIRECTIONS , BLOCKED AND SCABBED TOGETHER - SUB - STANDARD FRAMING. STRINGERS ONLY NAILED TO HEADER JOISTS AND COLUMNS. GUARDRAILS SPAN UP TO 10' - MISSING MID SPAN COLUMN SUPPORTS. GUARDRAILS ONLY 36'' HIGH. PORCH IS WEAK AND UNSTABLE. PLANS AND PERMIT REQUIRED FOR FRONT PORCH REPAIRS. REAR 1 STORY ENCLOSED PORCH BUILT - WEAK AND UNSTABLE - SUB - STANDARD FRAMING. WALL STUDS NOT RESTING ON FOUNDATION. ROOF RAFTERS NOT PROPERLY SUPPORTED AT WALLS. SUB - FASCIA MISSING - HOLES IN EAVES. PLANS AND PERMITS RQUIRED FOR REAR ENCLOSED PORCH AND FRONT EXTEREIOR PORCH REPAIRS. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | 1ST FLOOR BATHROOM , KITCHEN , AND BEDROOM FLOOR JOISTS - ROTTED , BROKEN , MISSING SECTIONS , SAGGING , AND MISSING SUPPORT - DANGEROUS AND HAZARDOUS. 1ST FLOOR FLOOR SHEATHING IS ROTTED , BROKEN , AND MISSING SECTIONS THROUGHOUT. PLANS AND PERMIT REQUIRED FOR 1ST FLOOR FLOOR JOIST , SHEATHING REPLACEMENT AND SUPPORT. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FLOOR BATHROOM , KITCHEN , AND BEDROOM FLOORS - BROKEN , LOOSE , AND MISSING FLOOR TILES WITH OPEN HOLES. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR AND ATTIC WALLS THROUGHOUT - BROKEN WITH HOLES , LOOSE , AND MISSING DRYWALL / PLASTER. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
RATS | BASEMENT , 1ST FLOOR , AND ATTIC LEVELS - RATS AND RAT HARBORAGE THROUGHOUT - DANGEROUS AND HAZARDOUS - 8 CHILDREN , ONE IS HANDICAPPED. REAR YARD - RATS AND RAT HARBORAGE. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
RAT PROOF OPENINGS | BUILDING INTERIOR AND EXTERIOR - RAT HOLES THROUGHOUT. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | REAR YARD - EXCESSIVE ACCUMULATION OF GARBAGE , JUNK , AND DEBRIS - ATTRACTING RATS - VERY UNSANITARY . | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | BUILDING INTERIOR - ALL LEVELS - UNSANITARY CONDITIONS - DIRT , GREASE AND GARBAGE ACCUMULATION - UNSANITARY CONDITIONS. REAR YARD - EXCESSIVE GARBAGE ACCUMULATION - UNSANITARY CONDITIONS. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | BUILDING INTERIOR STAIRWAY - 1ST TO ATTIC - LOOSE CARPET - FALL HAZARD. STAIR RAILS MISSING - DANGEROUS AND HAZARDOUS - FALLING HAZARD. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | ALL BUILDING LEVELS - BASEMENT , 1ST FLOOR AND ATTIC - SMOKE DETECTORS - MISSING. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT AND 1ST FLOOR - CARBON MONOXIDE DETECTORS MISSING. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | BASEMENT , 1ST FLOOR , AND ATTIC LEVELS - ELECTRICAL OUTLETS - LOOSE , BROKEN , HANGING , AND UNSAFE CONDITIONS.. DANGEROUS AND HAZARDOUS. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | ALL ELEVATIONS - GUTTERS AND DOWNSPOUTS - MISSING. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
COVER OUTLETS AND JBS | BASEMENT CEILING AND WALLS - OPEN ELECTRICAL JUNCTION BOXES. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
INSTALL COVERS | BASEMENT , 1ST FLOOR , AND ATTIC - ELECTRICAL SWITCHES AND OUTLET COVER PLATES - BROKEN , LOOSE , AND MISSING. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR/WRECK DANGER RESID PREM | 6006 S MORGAN ST | COMPLAINT | CLOSED | View | |
REPAIR FENCE | REAR FENCE LEANING | 6006 S MORGAN ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | BASEMENT - STORING EXCESSIVE AMOUNTS OF FLOOR TILES AND CONSTRUCTION EQUIPMENT AND MATERIALS. REAR AT REAR PORCH - LARGE TREE RUBBING BUILDING AND ROOF. | 6006 S MORGAN ST | COMPLAINT | FAILED | View |