Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SERVICE WALK, PASSAGE, AREAWAY | SIDE AND REAR SERVICE WALKS - CRACKED AND DETERIORATED CONCRETE. | 8710 S BUFFALO AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | REAR ENCLOSED PORCH / SMOKE DETECTOR - MISSING. | 8710 S BUFFALO AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | EAST ELEVATION / 2 STORY WOOD PORCH / COLUMN BASES - CONCRETE POURED AROUND BOTTOMS THAT ARE CRACKED. FOUNDATION STATUS - UNKNOWN. UNDERSIDE OF DECK COLUMNS - LEANING OUT OF PLUMB. COLUMN HALF LAP JOINTS MEASURE ONLY 8 INCHES AND ARE FASTENED WITH 2 BOLTS. 1ST FLOOR DECK STRUCTURE HAS DROPPED UP TO 3 INCHES. JOISTS - FASTENED WITH NAILS ONLY. STEEL RAILINGS - RUSTED AND DETATCHED FROM DECK. WEST ELEVATION / 3 STORY ENCLOSED PORCH / COLUMNS, BEAMS ROTTING AND DETERIORATED. EXTERIOR WALL - BLOWN OUT AT BOTTOM. DECK STRUCTURE IS LEANING 6 INCHES OUT OF LEVEL. STAIR SYSTEMS - LEANING UP TO 6 INCHES OUT LEVEL. STAIRS APPEAR TO BE ON THE VERGE OF COLLAPSE. ENTIRE STRUCTURE IS WEAK AND UNSTABLE. PLANS AND PERMIT REQUIRED TO REPLACE BOTH DANGEROUS AND HAZARDOUS PORCHES. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 8710 S BUFFALO AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | APT 1 / SMOKE DETECTOR BATTERY - REMOVED. | 8710 S BUFFALO AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST AND WEST ELEVATIONS / WINDOWS - BROKEN PANES. | 8710 S BUFFALO AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | INTERIOR STAIR; NO SMOKE DETECTOR. | 8710 S BUFFALO AVE | COMPLAINT | CLOSED | View |
OBSTRUCTIONS IN EXIT WAY | INTERIOR STAIR; STORAGE ITEMS. | 8710 S BUFFALO AVE | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | POST OWNERSHIP ON BUILDING. | 8710 S BUFFALO AVE | COMPLAINT | CLOSED | View |
UNSANITARY CONDITIONS-ANIMALS | FOYER AREA AND FRONT PORCH AREA; CAT FECES [ FEEDING CAT]. | 8710 S BUFFALO AVE | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO APARTMENTS. | 8710 S BUFFALO AVE | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | EAST PORCH; UPRIGHTS INSUFFICIENT LAP JOINT CUTS, SCAB WOOD ATTACH TO UPRIGHT, TREADS SPLIT.[SUBMIT PERMITS FOR REPAIRS]. | 8710 S BUFFALO AVE | COMPLAINT | CLOSED | View |