Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 6:53 PM
PIN: 11324050280000
Property Address: 6401 N SHERIDAN RD
City - Zip: CHICAGO - 60626
2023 Property Class: 391
2023 Township: 75 - Rogers Park
2023 Neighborhood: 75033
2023 Tax District: 75017
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 50 Violations
Violation Inspector Comments Address Category Status View
ARRANGE COMPLETED PERMIT INSP. 6401 N SHERIDAN RD PERMIT PASSED View
SUBMIT PLANS/GET VENT PERMIT 2 UNPERMITTED ROOFTOPS 6401 N SHERIDAN RD PERMIT PASSED View
ARRANGE ANNUAL INSP. 6401 N SHERIDAN RD COMPLAINT PASSED View
MAINTAIN MECH. VENT SYSTEM 6401 N SHERIDAN RD COMPLAINT PASSED View
INSTALL SMOKE DETECTORS SMOKE DETECTORS MISSING - 6TH,5TH,2ND,LAUNDRY ROOM 6401 N SHERIDAN RD PERIODIC PASSED View
REPAIR/REPLACE SMOKE DETECTORS SMOKE DETECTORS NOT FUNCTIONING 7TH,3RD 6401 N SHERIDAN RD PERIODIC PASSED View
CARB MONOX DETECT IN RESID CARBON MONOXIDE DETECTOR MISSING IN LAUNDRY ROOM 6401 N SHERIDAN RD PERIODIC PASSED View
OPEN TYPE VIOLATION REPAIR DOOR RESTRICTOR. 18-30-010, 13-20-120. 6401 N SHERIDAN RD PERIODIC CLOSED View
OPEN TYPE VIOLATION FASTEN ELEVATOR MACHINE ROOM LIGHT SWITCH PROPERLY. 18-30-010, 13-20-120. 6401 N SHERIDAN RD PERIODIC FAILED View
OPEN TYPE VIOLATION ELIMINATE WIRES BETWEEN WALL OUTLET AND ELEVATOR CONTROLLER. PROVIDE POWER SUPPLY PER CODE AND INDUSTRY STANDARDS. 18-30-010, 13-20-120. EV006143. 6401 N SHERIDAN RD PERIODIC FAILED View
OPEN TYPE VIOLATION PERFORM ANNUAL PRESSURE RELIEF AND HYDRAULIC SYSTEM TEST PER A17.1A-1997 RULE 1005.2A. 18-30-010, 13-20-120. 6401 N SHERIDAN RD PERIODIC FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR AT TOP OF FRONT STAIRWAY 6401 N SHERIDAN RD PERIODIC FAILED View
OPEN TYPE VIOLATION REPAIR DOOR RESTRICTOR TO OPERATE PROPERLY . 18-30-010, 13-20-120. 6401 N SHERIDAN RD PERIODIC FAILED View
OPEN TYPE VIOLATION CLEAN ELEVATOR PIT, CARTOP, AND MACHINE ROOM. 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PERFORM CATEGORY 1 TEST. TAG AND DOCUMENT AS REQUIRED. 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE CODE DATA TAG ON CONTROLLER OR MAINLINE DISCONNECT AS REQUIRED. 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL BULB GUARDS ON WORK LIGHTS LOCATED UNDER CAR AND ON CARTOP 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL COVERS ON ELECTRICAL BOXES IN HOISTWAY AND UNDER CAB 6401 N SHERIDAN RD PERIODIC FAILED View
LIFE SAFETY EVALUATION PLAN LIFE SAFETY EVALUATION DUE JANUARY 1, 2006 HAS NOT BEEN SUBMITTED AS OF JUNE 20, 2006 CALL JOSE APARICIO 312/743-7266 6401 N SHERIDAN RD COMPLAINT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA CLEAN ELEVATOR PIT 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR MALFUNCTIONING DOOR RESTRICTOR. 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA LOCATE AND REPAIR SOURCE OF IOL LEAKING IN ELEVATOR PIT. 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR OR INSTALL PIT LIGHTING, SAFETY HAZARD, ALSO INSTALL PIT LADDER, FALL HAZARD 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA SHOW PROOF OF COMPLIANCE WITH SECTION 8.6.5.8 OF A17.1-2007 (BULKHEAD REQUIREMENTS) 6401 N SHERIDAN RD PERIODIC FAILED View
PROVIDE PER SECTION CODE 13-196-085, STAIRWELL IDENTIFICATION MISSING AT EACH FLOOR LEVEL INTERIOR OF STAIRWELL.NOTE: SCISSOR STAIRS CROSS SIGNS MUST BE CONSISTENT IN EACH STAIWELL. 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN EXIT SIGN ILLUMINATED EXIT SIGNS AND DIRECTIONAL SIGNS ARE NOT BATTERY BACK-UP AS REQUIRED. 6401 N SHERIDAN RD PERIODIC FAILED View
PROVIDE PER SECTION CODE 13-78-080(C) MISSING IN ELEVATOR LOBBIES, HIGH-RISE BUILDING'S CORE FLOOR PLAN. 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR HOLE IN WALL BESIDE CONTROLLER, OPEN HOISTWAY 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR BROKEN LIGHT SWITCH FOR MACHINE ROOM LIGHTING. 6401 N SHERIDAN RD PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA WORKING DOOR RESTRICTOR REQUIRED. 6401 N SHERIDAN RD PERIODIC PASSED View
ARRANGE PREMISE INSPECTION NO ENTRY INTO DWELLING UNITS-ARRANGE FOR INSPECTION 6401 N SHERIDAN RD PERIODIC PASSED View
STOP NUISANCE TO NEIGHBORS 6401 N SHERIDAN RD COMPLAINT PASSED View
OPEN TYPE VIOLATION INSTALL "IN CASE OF FIRE" PICTOGRAPHS AT ALL LANDING. 18-30-010, 13-20-120. 6401 N SHERIDAN RD PERIODIC FAILED View
OPEN TYPE VIOLATION CLEAN CARTOP AND INSTALL COVERS ON CARTOP DEVICES. 18-30-010, 13-20-120. 6401 N SHERIDAN RD PERIODIC CLOSED View
OPEN TYPE VIOLATION REPAIR TELEPHONE. 18-30-010, 13-20-120. 6401 N SHERIDAN RD PERIODIC FAILED View
OPEN TYPE VIOLATION REPAIR DOOR RESTRICTOR TO OPERATE PROPERLY . 18-30-010, 13-20-120. 6401 N SHERIDAN RD PERIODIC FAILED View
OPEN TYPE VIOLATION PERFORM CATEGORY I TEST AS REQUIRED BY CODE. 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE WORKING MACHINE ROOM LIGHTING 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR DOOR RESCTRICTOR TO WORK PROPERLY (PREVIOUSLY CITED) 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR AND MAINTAIN PASSENGER ELEVATOR TO CORRECT CONSTANT SHUT DOWNS. NOTIFY THE ELEVATOR BUREAU WHEN COMPLETE SO ANNUAL INSPECTION CAN BE COMPLETED. 6401 N SHERIDAN RD PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA LABEL INSIDE OF LANDING DOORS WITH FLOOR NUMBERS. 6401 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA COVERS REQUIRED ON DOOR LOCKS, DUCTWORK, AND JUNCTION BOXES. 6401 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL BRAILLE FLOOR IDENTIFICATION AT ALL LANDINGS. 6401 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA HEAVY DUTY MAINLINE DISCONNECT REQUIRED. 6401 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA CLEAN DOWN HOISTWAY (RAILS,BRACKETS, ETC.) 6401 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PATCH MACHINE ROOM WALL WHERE DUCT PENETRATES. 6401 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REMOVE PIPING IN HOISTWAY THAT IS NO LONGER BEING USED. 6401 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA CHANGE SMOKE RESET SWITCH TO MOMENTARY TYPE. 6401 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA INSTALL "CAUTION - LOW OVERHEAD" SIGN. 6401 N SHERIDAN RD PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA SIGN REQUIRED ON MACHINE ROOM DOOR. 6401 N SHERIDAN RD PERMIT FAILED View