Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR EAVES | FRONT ELEVATION/ ROOF EAVE ABOVE FRONT PORCH - BROKEN WOOD AND ROTTED WITH PEELING PAINT. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
MAINTAIN WINDOW | ALL ELEVATIONS/ ALL LEVELS/ WINDOW FRAMES - SEVERELY ROTTED WOOD WITH PEELING PAINT. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
SCREEN OUTER DOORS, WINDOWS | ALL ELEVATIONS/ ALL LEVELS/ VARIOUS WINDOWS - MISSING SCREENS. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | FRONT 1-STORY CONCRETE PORCH/ ENTIRE NORTH RAILING SECTIONS - MISSING. (FALL HAZARD) DANGEROUS AND HAZARDOUS CONDITIONS.PERMIT ONLY REQUIRED FOR FRONT PORCH REPAIRS.REAR 2-STORY ENCLOSED WOOD PORCH/ COLUMNS HAVE BUTTED JOINTS THAT ARE ONLY TOE-NAILED TOGETHER. BEAMS - ONLY NAILED TO COLUMNS. ALL DECKS - UNDERSIZED 2X6 DECK JOISTS SPAN OVER 8 FEET AND ARE ONLY NAILED TO HEADER JOISTS. STRINGERS - UPPER ENDS ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. 2ND FLOOR INNER RAILING - ONLY 33 INCHES HIGH. ALL RAILINGS ARE ONLY NAILED TO COLUMNS AND POSTS. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPAIRS. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
RELOCATE SMOKE DETECTOR | 1ST AND 2ND FLOOR APARTMENTS/ SMOKE DETECTORS ARE TOO LOW ON WALL. (APPROXIMATELY 14 TO 20 INCHES FROM CEILING). | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR APARTMENT/ SOUTH BEDROOM CEILING - WATER DAMAGED WITH LARGE HOLE IN PLASTER. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY AND REAR ENCLOSED PORCH - MISSING SMOKE DETE CTORS. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR HARDWARE | REAR EXTERIOR DOOR / KNOB AND DEADBOLT DO NOT LOCK; UNSECURE. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | BASEMENT - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | 5925 S BISHOP 2ND FLR LIV RM 66 DEGREE'S HEATING SYSTEMS ARE OFF NO HEAT PROVIDED | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | SPACE HEATERS ARE OUT OF SERVICE NO HEAT PROVIDED @ 5925 S BISHOP 2ND FLR | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND PERMITS AUTHORING INTERIOR ALTERATIONS IN BASEMENT,PREVIOUS STORAGE.NOW BEING USED AS A DWELLING UNIT.PARTITION WALLS,KITCHEN AND BATH INSTALLED. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
WORK NOT ALLOWED | REMOVE ALL WORK INCLUDING PLUMBING AND ELECTRIC FIXTURES IN BASEMENT,INSTALLED WITHOUT PERMITS. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
1HR PUB.CORRIDOR IN MULT. D.U. | OPEN JOISTS IN BASEMENT CEILINGS,WHERE DWELLING UNIT IS. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR DOOR FRAME, MULLION | BASEMENT DOOR REAR - HINGES (DANGEROUS AND HAZARDOUS) FRAME FALLING APART. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
EGRESS -BASEMENT | BASEMENT - ONE EGRESS | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
PAINT SHUT | BASEMENT WINDOWS PAINTED SHUT. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
HEATING PLANT ENCLOSURE | BASEMENT FURNACE NOT ENCLOSED | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
UNINTERRUPTED EXIT AT GRADE | REAR GATE CHAINED AND PADLOCKED. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO APARTMENT 2 | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS,REAR ENCLOSED PORCH / BASEMENT. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR - BASEMENT. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
POST OWNER/MANAGERS NAME/# | MISSING OWNER INFORMATION SIGN. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION FRONT HANDRAIL SHAKEY,GUARDRAIL MISSING AT LANDING,PERMIT ONLY. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | BOARDED UP WINDOWS AT BASEMENT (ALL ELEVATIONS) AND REAR 1ST FLOOR,2ND FLOOR WINDOWS.BROKEN AT REAR & SOUTH ELEVATION, 1ST FLOOR. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | ROTTED,DETERIORATED SIDING AT SOUTH ELEVATION. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
PROVIDE LAV TO FAMILY UNIT | NO WORKING TOILET,TUB NOR SINK IN BASEMENT BATH. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
INT WALL/CEILING PEELING PAINT | BASEMENT DRYWALL MISSING SECTIONS BASEMENT. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
PROVIDE COLD WATER TO FICTURES | NO COLD WATER TO FIXTURES IN ENTIRE BUILDING. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REMOVE STAGNANT WATER BSMT | STANDING RAIN WATER AT REAR DOOR (INSIDE) | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPAIR INTERIOR WALLS/CEILING | 1ST FLOOR KITCHEN PEELING PAINT ON CEILING PAINT ON CEILING, WATER DAMAGED ON SOUTH BEDROOM CEILING. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPLACE D&H PORCH | REAR ENCLOSED PORCH DANGEROUS AND HAZARDOUS ROTTED,BULGING EXTERIOR WALLS,LANDINGS COLLAPSED GRADE TO 1ST,TREADS,HANDRAILS AND STRINGER LOOSELY ATTACHED LEANING,WEAK UNDER LOAD,BEAMS TOE-NAILED TO COLUMN.PLANS AND PERMITS TO REPLACE. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT ELEVATION/ BASEMENT WINDOW - BROKEN PANE.REAR ELEVATION/ ALL WINDOWS - BROKEN PANES. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER TO FIXTURES IN ENTIRE BUILDING. | 5925 S BISHOP ST | COMPLAINT | CLOSED | View |