Chicago Building Violations Data: 26 Violations
Violation Inspector Comments Address Category Status View
CARB MONOX DETECT IN RESID 2447 N LONG AVE COMPLAINT FAILED View
WINDOW REPAIR FOR AIR SEEPAGE 2447 N LONG AVE COMPLAINT FAILED View
HEAT UNIT ADEQUATELY 2447 N LONG AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS 2447 N LONG AVE COMPLAINT FAILED View
RELOCATE SMOKE DETECTOR 1ST. FL. APT. /RELOCATE SMOKE DETECTOR INSTALLED ON THE WALL TOO CLOSE 2 INCHES TO CEILING; 2447 N LONG AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 1ST. FL. APT. /CARBON MONOXIDE DETECTOR - MISSING; 2447 N LONG AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT /INTERIOR STAIRWAY AND REAR 3 STORY ENCLOSED WOOD PORCH /SMOKE DETECTOR - MISSING; 2447 N LONG AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT NORTH AND SOUTH ELEVATION /ROOF GUTTERS AND DOWNSPOUTS - MISSING. 2447 N LONG AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIR SYSTEM /HAND RAILS - MISSING; 2447 N LONG AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS. 2447 N LONG AVE COMPLAINT FAILED View
REPAIR SCREENS REPAIR/ REPLACE DAMAGED SCREENS THROUGHOUT. 2447 N LONG AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID 1ST. FL. APT. /CARBON MONOXIDE DETECTOR - MISSING; 2447 N LONG AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT APT. AND ADDITION AT UPPER LEVEL ALTERED TO DWELLING UNITS OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES; 2447 N LONG AVE COMPLAINT PASSED View
REPAIR EAVES NORTH AND SOUTH ELEVATION /EAVES AND SOFFIT - MISSING; 2447 N LONG AVE COMPLAINT PASSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE BASEMENT APT. AND ADDITION AT UPPER LEVEL ALTERED TO DWELLING UNITS WITHOUT PERMIT. 2447 N LONG AVE COMPLAINT PASSED View
REPAIR/REBUILD GARAGE OR SHED GARAGE /WEST ELEVATION - EXTERIOR FRAME WALL - [APPROXIMATELY 20 FEET LONG] UP TO 17 FEET LONG SECTION ¿ MISSING - [2X4 ROOF RAFTERS RESTING ON DOUBLE 2X4 TOP PLATES].PERMIT REQUIRED. 2447 N LONG AVE COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR 3 STORY ENCLOSED WOOD PORCH;STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; RAILINGS /GUARD RAILING SECTIONS ONLY 23 INCHES HIGH, ARE OF LADDER TYPE DESIGN, WITH HORIZONTAL TIES SPACED UP TO 13 INCHES APART; STAIR RAILING SECTIONS OBNLY ONLY 23 INCHES HIGH, ARE OF LADDER TYPE DESIGN, WITH ANGLE TIES SPACED UP TO 7 INCHES APART; PERMIT REQUIRED; 2447 N LONG AVE COMPLAINT PASSED View
REPAIR EAVES NORTH AND SOUTH ELEVATION /EAVES AND SOFFIT - MISSING; 2447 N LONG AVE COMPLAINT FAILED View
REPAIR/REBUILD GARAGE OR SHED GARAGE /WEST ELEVATION - EXTERIOR FRAME WALL - [APPROXIMATELY 20 FEET LONG] UP TO 17 FEET LONG SECTION ¿ MISSING - [2X4 ROOF RAFTERS RESTING ON DOUBLE 2X4 TOP PLATES].PERMIT REQUIRED. 2447 N LONG AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR 3 STORY ENCLOSED WOOD PORCH;STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; RAILINGS /GUARD RAILING SECTIONS ONLY 23 INCHES HIGH, ARE OF LADDER TYPE DESIGN, WITH HORIZONTAL TIES SPACED UP TO 13 INCHES APART; STAIR RAILING SECTIONS OBNLY ONLY 23 INCHES HIGH, ARE OF LADDER TYPE DESIGN, WITH ANGLE TIES SPACED UP TO 7 INCHES APART; PERMIT REQUIRED; 2447 N LONG AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT APT. AND ADDITION AT UPPER LEVEL ALTERED TO DWELLING UNITS OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES; 2447 N LONG AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT /INTERIOR STAIRWAY AND REAR 3 STORY ENCLOSED WOOD PORCH /SMOKE DETECTOR - MISSING; 2447 N LONG AVE COMPLAINT PASSED View
REPAIR GUTTER & DOWNSPOUT NORTH AND SOUTH ELEVATION /ROOF GUTTERS AND DOWNSPOUTS - MISSING. 2447 N LONG AVE COMPLAINT PASSED View
RELOCATE SMOKE DETECTOR 1ST. FL. APT. /RELOCATE SMOKE DETECTOR INSTALLED ON THE WALL TOO CLOSE 2 INCHES TO CEILING; 2447 N LONG AVE COMPLAINT PASSED View
POST OWNER/MANAGERS NAME/# BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; 2447 N LONG AVE COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM FRONT INTERIOR STAIR SYSTEM /HAND RAILS - MISSING; 2447 N LONG AVE COMPLAINT PASSED View