Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
CARB MONOX DETECT IN RESID | 2447 N LONG AVE | COMPLAINT | FAILED | View | |
WINDOW REPAIR FOR AIR SEEPAGE | 2447 N LONG AVE | COMPLAINT | FAILED | View | |
HEAT UNIT ADEQUATELY | 2447 N LONG AVE | COMPLAINT | FAILED | View | |
INSTALL SMOKE DETECTORS | 2447 N LONG AVE | COMPLAINT | FAILED | View | |
RELOCATE SMOKE DETECTOR | 1ST. FL. APT. /RELOCATE SMOKE DETECTOR INSTALLED ON THE WALL TOO CLOSE 2 INCHES TO CEILING; | 2447 N LONG AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST. FL. APT. /CARBON MONOXIDE DETECTOR - MISSING; | 2447 N LONG AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT /INTERIOR STAIRWAY AND REAR 3 STORY ENCLOSED WOOD PORCH /SMOKE DETECTOR - MISSING; | 2447 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR GUTTER & DOWNSPOUT | NORTH AND SOUTH ELEVATION /ROOF GUTTERS AND DOWNSPOUTS - MISSING. | 2447 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIR SYSTEM /HAND RAILS - MISSING; | 2447 N LONG AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO RESPONSE,UNVERIFIED DETECTORS. | 2447 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | REPAIR/ REPLACE DAMAGED SCREENS THROUGHOUT. | 2447 N LONG AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 1ST. FL. APT. /CARBON MONOXIDE DETECTOR - MISSING; | 2447 N LONG AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT APT. AND ADDITION AT UPPER LEVEL ALTERED TO DWELLING UNITS OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES; | 2447 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR EAVES | NORTH AND SOUTH ELEVATION /EAVES AND SOFFIT - MISSING; | 2447 N LONG AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE BASEMENT APT. AND ADDITION AT UPPER LEVEL ALTERED TO DWELLING UNITS WITHOUT PERMIT. | 2447 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE /WEST ELEVATION - EXTERIOR FRAME WALL - [APPROXIMATELY 20 FEET LONG] UP TO 17 FEET LONG SECTION ¿ MISSING - [2X4 ROOF RAFTERS RESTING ON DOUBLE 2X4 TOP PLATES].PERMIT REQUIRED. | 2447 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY ENCLOSED WOOD PORCH;STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; RAILINGS /GUARD RAILING SECTIONS ONLY 23 INCHES HIGH, ARE OF LADDER TYPE DESIGN, WITH HORIZONTAL TIES SPACED UP TO 13 INCHES APART; STAIR RAILING SECTIONS OBNLY ONLY 23 INCHES HIGH, ARE OF LADDER TYPE DESIGN, WITH ANGLE TIES SPACED UP TO 7 INCHES APART; PERMIT REQUIRED; | 2447 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR EAVES | NORTH AND SOUTH ELEVATION /EAVES AND SOFFIT - MISSING; | 2447 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE /WEST ELEVATION - EXTERIOR FRAME WALL - [APPROXIMATELY 20 FEET LONG] UP TO 17 FEET LONG SECTION ¿ MISSING - [2X4 ROOF RAFTERS RESTING ON DOUBLE 2X4 TOP PLATES].PERMIT REQUIRED. | 2447 N LONG AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY ENCLOSED WOOD PORCH;STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STRINGERS, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY; RAILINGS /GUARD RAILING SECTIONS ONLY 23 INCHES HIGH, ARE OF LADDER TYPE DESIGN, WITH HORIZONTAL TIES SPACED UP TO 13 INCHES APART; STAIR RAILING SECTIONS OBNLY ONLY 23 INCHES HIGH, ARE OF LADDER TYPE DESIGN, WITH ANGLE TIES SPACED UP TO 7 INCHES APART; PERMIT REQUIRED; | 2447 N LONG AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT APT. AND ADDITION AT UPPER LEVEL ALTERED TO DWELLING UNITS OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES; | 2447 N LONG AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT /INTERIOR STAIRWAY AND REAR 3 STORY ENCLOSED WOOD PORCH /SMOKE DETECTOR - MISSING; | 2447 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR GUTTER & DOWNSPOUT | NORTH AND SOUTH ELEVATION /ROOF GUTTERS AND DOWNSPOUTS - MISSING. | 2447 N LONG AVE | COMPLAINT | PASSED | View |
RELOCATE SMOKE DETECTOR | 1ST. FL. APT. /RELOCATE SMOKE DETECTOR INSTALLED ON THE WALL TOO CLOSE 2 INCHES TO CEILING; | 2447 N LONG AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; | 2447 N LONG AVE | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIR SYSTEM /HAND RAILS - MISSING; | 2447 N LONG AVE | COMPLAINT | PASSED | View |