Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | NO OWNER I.D SIGN POSTED. | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST ELEVATION VARIOUS LOCATIONS BROKEN WINDOW PANES. | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO RESPONSE/ENTRY AT TIME OF INSPECTION.UNABLE TO GAIN ENTRY TO VERIFY OCCUPANCY,DETECTORS AND OVERALL CONDITION FOR 2016 ANNUAL INSPECTION. | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALL REPAIR (1) SEVERE WASHED OUT MORTAR ON WEST, NORTH AND EAST ELEVATIONS (2) LIMESTONE LOOSE, CRACKING, WASHED OUT MORTAR (3) NORTHWEST CORNER DAMAGED BRICK LIMESTONE LOOSE PIECES (4) REMOVE SIGN FROM SOUTH ELEVATION CHECK BRICK BEHIND AND SIGN CONNECTIONS | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
SCRAPE/PAINT FIRE ESCAPE | FIRE ESCAPE PAINT AND REPAIR RUST | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | PROVIDE STRUCTURAL ENGINEERS REPORT FOR 100% OF BUILDING INSPECTION (SEND TO J. APARICIO 2240 W OGDEN 60612 | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
PROVIDE SIDEWALK SHED F/PROTCT | PROVIDE CANOPY TO FRONT OF BUILDING RECEIVE PERMIT FROM DEPARTMENT OF STREET AND SANITATION | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
PARAPET | PARAPET NORTH ELEVATION SEVERE WASHED OUT MORTAR | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST PROPER OWNER MANAGEMENT I.D. (NOT P.O.BOX ) | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
NO POSTED ADDRESS | POST PROPER ADDRESS | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
REPAIR LINTELS | LINTELS (1) RUSTED, BOWING ALL ELEVATIONS VARIOUS LOCATIONS (2) WINDOW STONE LINTELS BOWING WASHED OUT MORTAR, CRACKED DAMAGED SECURE | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE PLANS AND PERMITS BEFORE COMMENCING ANY WORK | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
PARAPET | AT EAST AND WEST ELEVATIONS, - PARAPET IS SEVERELY DAMAGE, DANGEROUS AND HAZARDOUS, - WALL IS OUT OF PLUMB AND DANGEROUSLY LEANING OVER THE PUBLIC SIDEWALK, MASONRY IS BULGING LEANING OUTWARD WITH THE RISK OF COLLAPSE AT ANY TIME. AT THE TIME OF INSPECTION SAFAFETY CANOPY IS ON SITE EAST ELEVATION,- AT EAST ELEVATION PARAPET FIRE ESCAPE IS SUPPORTED WHERE MASONRY IS SEVERELY DAMAGE, MASONRY IS BULGING OUT WITH THE RISK OF COLLAPSING WITH HIGH WINDS, - AT WEST ELEVATION TWO SIDE PILASTERS AT THE PARAPET ARE BUCKLING, OUT OF PLUMB WITH OPEN JOINTS. AT SOUTH PARAPET A LARGE PORTION OF THE PARAPET APROXIMETALLY 23'X 8' PORTION IS MISSING FROM LOAD BEARING WALL, - WALL BELOW HAS SPALLING BRICKS AND ERODED MORTAR, - AT NORTH ELEVATION PARAPER, - WALL IS OUT OF PLUMB, MASONRY IS BULGING LEANING OUTWARD FRON THE NORTH WEST CORNER OF THE BUILDING UP TO NORTH ELEVATION CHIMNEY.PLANS AND PERMIT ARE REQUIRED TO REPAIR EXTERIOR WALL. | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
PROTECT SIDEWALK DURING CONST | PROTECT ENTRANCE AND PUBLIC SIDEWALK WITH SAFETY CANOPY.PERMIT ISSUED BY DEPARTMENT OF TRANSPORTATION REQUIRED FOR SUCH INSTALLATION.PLEASE NOTE AT THE TIME OF INSPECTION THERE IS A SAFETY CANOPY ON WEST ELEVATION. | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
REGISTER/SECURE/INSURE-VACANT | REGISTER, INSURE AND SECURE VACANT BUILDING WITHIN 30 DAYS OF BECOME VACANT,- BUILDING APARENTLY IS VACANT. | 7411 S STONY ISLAND AVE | PERIODIC | FAILED | View |
OPEN | 7411 S STONY ISLAND AVE | PERMIT | FAILED | View | |
MAINTAIN OR REPAIR ELECT ELEVA | RE-SCHEDULE INSPECTION | 7411 S STONY ISLAND AVE | PERMIT | PASSED | View |
MAINTAIN EXIT SIGN ILLUMINATED | THROUGHOUT THIS 6 STORY BUILDING THERE ARE NUMEROUS MISSING EXIT SIGNS. OF THE FEW EXIT SIGNS THAT EXISTED, NONE WERE FUNCTIONING. THERE ARE NO DIRECTIONAL SIGNS WHAT SO EVER. THE CONDITION FOR SIGN DESIGNATED EGRESS DOES NOT EXIST. THIS IS AN EXTREMELY DANGERPOUS AND HAZARDOUS CONDITION.SECTION 14X-5-505.6.1. | 7411 S STONY ISLAND AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | THE EXIT PATHWAY TO THE REAR EXIT DOOR ON THE 3RD FLOR (ILLEGAL EVENT SPACE) IS COMPLETELY OBSTRUCTED BY JUNK, DEBRIS AND STORED ITEMS. DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.1.2. | 7411 S STONY ISLAND AVE | COMPLAINT | FAILED | View |
EXPOSED WIRING | AT ALL AREAS OF THIS BUILDING THERE IS A SUBSTANTIAL AMOUNT OF UNPIPED, EXPOSED ELECTRICAL WIRING.DANGEROUS AND HAZARDOUS.SECTION 14X-7-703 / 705. | 7411 S STONY ISLAND AVE | COMPLAINT | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | THE EGRESS FROM THE OFFICES ON THE 2CD FLOOR ARE ACROSS A ROOF WITH ABSOLUTELY NO DIRECTIONAL SIGNS TO THE FIRE ESCAPE (THAT CANNOT BE SEEN) AT THE REAR OF THE BUILDING. THERE IS NO EXIT ILLUMINATION. THERE IS NO DEDICATED EXIT WALKWAY WITH HANDRAILS. THIS IS A DANGEROUS AND HAZARDOUS CONDITION.SECTION 14X-5-505.1.2, 14X-5-505.12.6 AND 14X-5-505.12.7. | 7411 S STONY ISLAND AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | TRHIS IS A 6 STORY IND2USTRIAL WAREHOUSE0 ZONE0D C2-2. TH ERE IS AN OFFYICE ON THE O2CD FLOUOR, AN UNNLICENSEGD / PPA EVENT SPACE ON PTHE 3RD EFLOOR OAND ANP APARLTMENT ON THEE 6TH FLOOR. THERE ARE NO PLAN S, PERMITS OR LICIENSE APPLICNATIONS FOR AANY OF THE ACTTIVITTY INE THIS BUILDING.N THE INSTALLATION OFD THE OFFAICE AND APARTNMENT WCAS DONE WITHOUT PLAENS / PERMITS. THE PP>A ACTIVITY IS ONGOING WITHOUT LICENSE>AT THE TIME OF THIS INSPECTBION< A LARGE APARTY IN PROGRCESS WITH FOOD ? ALCOHOPL BEING SERVED / SOLD. TICKETS WERE SOLD TO ATTEND THIS U/NLICENSED EVENT. T HERE WERE OV EDOB ISSUED CLOSURES AND VACATED THE EVENT SPACE WITH THE ASSISSTANCE OF THE CPD.SECTION 14A-4-401.1. | 7411 S STONY ISLAND AVE | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | THE CONDITION OF EXIT ILLUMINATION IN THIS 6 STORY BUILDING IS PROBLEMATIC. THERE IS INSUFFICIENT DEDICATED EXIT ILLUMINATION AT THE REAR FIRE ESCAPE. THERE IS NO EXIT ILLUMINATION AT A 2CD FLOOR ROOF AREA FOR ACCESS TO THE REAR FIRE ESCAPE. ALSO, THERE IS NO SYSTEM III EMERGENCY LIGHTING SYSTEM.DANGEROUS AND HAZARDOUS.SECTION 14X-5-505.6.1. AND 14X-6-602.3. | 7411 S STONY ISLAND AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL WORK PERFORMED WITHOUT PLANS / PERMITS. REMOVE THE PARTION WALLS FORMING ROOMS AT THE 2CD FLOOR OFFICE AND THE 6TH FLOOR APARTMENT. REMOVE ALL OF THE ELECTRICAL PIPING / WIRING / FIXTURES INSTALLED WITHOT PERMITS. REMOVE ALL OF THE PLUMBING PIPING / FIXTURES INSTALLED WITHOUT PERMIT. REMOVE ALL OF THE HVAC EQUIPMENT INSTALLED WITHOUT PERMIT.SECTION 14A-4-401.1. | 7411 S STONY ISLAND AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 7411 S STONY ISLAND AVE | PERMIT | FAILED | View |