The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PERMIT REQUIRED - CONTRACTOR | SR#07-0046007 OBTAIN PERMIT FOR BASEMENT DWELLING, PARTITION FORMING WALLS, PLUMBING AND ELECTRICAL | 3120 W 54TH ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMIT FOR DRYWALL, ELECTRICAL, AND PLUMBING, NEWLY INSTALLED AT ATTIC | 3120 W 54TH ST | COMPLAINT | PASSED | View |
EGRESS -BASEMENT | BASEMENT: ONLY ONE EXIT | 3120 W 54TH ST | COMPLAINT | PASSED | View |
LIGHT AND VENT | BASEMENT: GLASS BLOCK WINDOW | 3120 W 54TH ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | BASEMENT: NO CARBON MONOXIDE DETECTOR | 3120 W 54TH ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | BASEMENT: NO SMOKE DETECTOR | 3120 W 54TH ST | COMPLAINT | PASSED | View |
CEILING HEIGHT - 7' - BASEMENT | BASEMENT: CEILING HEIGHT NOT 7 FEET | 3120 W 54TH ST | COMPLAINT | PASSED | View |
PERMIT REQUIRED - CONTRACTOR | FRONT SOLID WOOD 5'-6" FENCE BUILT - NO PERMIT OBTAINED. | 3120 W 54TH ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION - BROKEN BASEMENT WINDOW PANE. | 3120 W 54TH ST | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | NORTH AND EAST ELEVATIONS - MISSING DOWNSPOUTS. | 3120 W 54TH ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR STAIRS GRADE TO 2ND - ERODED CONCRETE.; UNDERSIZED 2"X6" DECK JOIST SPAN 8'-9", CONCRETE POURED AROUND COLUMNS, BEAMS SUPPORTED WITH 2"X4", GUARDRAILS ARE ONLY 35", STAIRS ARE ONLY 29" WIDE, MIDLANDING IS 29", NO LANDING ON ATTIC LEVEL. PLANS AND PERMIT REQUIRED TO REPLACE EXTERIOR STAIRS. | 3120 W 54TH ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH MISSING HANDRAILS GRADE TO 1ST, AT ATTIC STAIR SYSTEM SUPPORTED BY 2X4 LUMBER NAIL TO WALL. SUBMIT PLAN AND PERMIT FOR PORCH BUILT AT REAR GRADE TO ATTIC. | 3120 W 54TH ST | COMPLAINT | CLOSED | View |
REPAIR DOWNSPOUT | REAR MISSING DOWNSPOUT. | 3120 W 54TH ST | COMPLAINT | CLOSED | View |
PERMIT REQUIRED | OBTAIN PERMIT FOR DOOR OPEN CUT OUT AT REAR ATTIC. | 3120 W 54TH ST | COMPLAINT | CLOSED | View |
PAINT SHUT | BASEMENT BATHROOM: NO VENTILATION | 3120 W 54TH ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | REAR YARD EXCESSIVE STORAGE, COUCH,REFRIGERATOR AND OTHER HOUSEHOLD ITEMS. | 3120 W 54TH ST | COMPLAINT | CLOSED | View |