Chicago Building Violations Data: 50 Violations
Violation Inspector Comments Address Category Status View
NO PERMIT AWNING SIGN TWO (2) AWNING SIGN READS "DTA DEVELOPMENT AND CONSTRUCTION INC SIZE OF AWNING APPROXIMATELY 4' X 20' AND 4' X 4 ON THOMAS STREET 1059 N LARAMIE AVE COMPLAINT FAILED View
1HR FLR OVER BSMT, 1 OR 2 DU OPEN JOISTS OBSERVED THROUGH OUT BASEMENT AREA 1059 N LARAMIE AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FITTINGS SECOND FLOOR- TUB SPOUT AWAY FROM WALL 1059 N LARAMIE AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL KITCHEN COUNTERTOP AREA'S, BATHROOM AND LAUNDRY AREA'S- 18-27-210.8 1059 N LARAMIE AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO 1ST FLOOR COMMERCIAL 1059 N LARAMIE AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS FURNACES OUT OF SERVICE AT TIME OF INSPECTION 1E 5153, 2E 5153, 2W 5153 1059 N LARAMIE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS THROUGH OUR BUILDING 1059 N LARAMIE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTORS THROUGH OUT BUILDING 1059 N LARAMIE AVE COMPLAINT FAILED View
UNAPPROVED HEATING DEVICE USING COOKING STOVE AS HEATING DEVICE THROUGH OUT BUILDING 1059 N LARAMIE AVE COMPLAINT FAILED View
SUBMIT STRUCT. ENG. RPT (INT.) PROVIDE ENGINEERS REPORT ON STRUCTURAL INTEGRITY OF SOUTH AND EAST WALL (STRESS FRACTURES) ALSO FLOOR SYSTEM IT SUPPORTS 1059 N LARAMIE AVE COMPLAINT FAILED View
PARAPET & COPING REPAIR SOUTH AND EAST PARAPETS SEVERELY DETERIORATED, PERMIT REQUIRED FOR REBUILDING PARAPETS 1059 N LARAMIE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM SOUTH PORCH WITH FOLLOWING DEFECTS, (1) UNVERIFIED FOOTING, JOIST PULLING AWAY FROM WALL DUE TO WALL FRACTURES, OVERSIZED RISERS, UNDERSIZE THREADS. ALL SECTIONS JUST NAILED, PLANS AND PERMITS REQUIRED FOR REPLACEMENT OF PORCH 1059 N LARAMIE AVE COMPLAINT FAILED View
UNINTERRUPTED EXIT AT GRADE ONLY ONE MEANS OF EGRESS FROM 2ND FLOOR DUE TO SOUTH PORCH IN DANGEROUS AND HAZARDOUS CONDITIONS 1059 N LARAMIE AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM STAIRS AT 5153 LOOSE THREADS AND RISERS, MOVE UNDER LOAD PLANS AND PERMITS REQUIRED TO FIX 1059 N LARAMIE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING CEILING AND WALLS 2W 5153 WATER DAMAGED CEILING IN KITCHEN READY TO CAVE IN 1059 N LARAMIE AVE COMPLAINT FAILED View
REPAIR DOOR, INT. HOLE IN BATHROOM DOOR 1E 5153 1059 N LARAMIE AVE COMPLAINT FAILED View
CONTRARY TO ORIGINAL PLAN SOUTH PORCH PARTIALLY ENCLOSED WITH 8 INCH C.M.U. CONCRETE BLOCK 1059 N LARAMIE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING FIRST FLOOR EAST APARTMENT+2ND FLOOR, EAST+WEST UNITS KITCHEN SINK-REPLACE CORRIGATED TUBING USED FOR SINK TRAP WASTE AND INSTALL APPROVED MATERIAL 1059 N LARAMIE AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE FIRST FLOOR EAST APARTMENT+2ND FLOOR,EAST+WEST UNITS KITCHEN SINK, LAVATORY AND TOILET, REPLACE FLEX WATER SUPPLIES WITH COPPER SUPPLIES 1059 N LARAMIE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET SECOND FLOOR-TUB FAUCET DRIPPING, REPAIR OR REPLACE 1059 N LARAMIE AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC HIRE A LICENSED PLUMBING CONTRACTOR FOR ALL VIOLATION CORRECTIONS 1059 N LARAMIE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING SECOND FLOOR EAST LAVATORY- FLEX WASTE PIPE, REPLACE WITH RIGID TUBING 1059 N LARAMIE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING SECOND FLOOR EAST KITCHEN SINK-FLEX WASTE PIPE, REPLACE WITH RIGID TUBING 1059 N LARAMIE AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE SECOND FLOOR EAST KITCHEN SINK-FLEX WATER SUPPLIES, REPLACE WITH COPPER SUPPLIES 1059 N LARAMIE AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE 5153 W THOMAS SECOND FLOOR WEST-KITCHEN SINK-REPLACE FLEX WATER SUPPLIES WITH COPPER SUPPLIES 1059 N LARAMIE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING 5153 W THOMAS KITCHEN SINK WASTE REPLACE CORRIGATED WASTE PIPE WITH RIGID TUBING 1059 N LARAMIE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE FAUCET 5153 W THOMAS TUB FAUCET DRIPPING, REPAIR OR REPLACE 1059 N LARAMIE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE 5153 W THOMAS TUB SURFACE IS CHIPPED IN MULTIPLE LOCATIONS, REPAIR OR REPLACE 1059 N LARAMIE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE WASTE PIPING FIRST FLOOR EAST- KITCHEN FLOOR EAST- FLEX WASTE, REPLACE WITH RIGID TUBING 1059 N LARAMIE AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE FIRST FLOOR EAST- KITCHEN SINK -FLEX WATER, REPIPE WITH COPPER SUPPLIES 1059 N LARAMIE AVE COMPLAINT FAILED View
DEFECTIVE LIGHTING SERVICE REPLACE DEFECTIVE SERVICE DISCONNECT THAT HAS SPLICE SERVICE CONDUCTORS WITHOUT OVER CURRENT PROTECTION DEVICE - DANGEROUS AND HAZARDOUS * 1059 N LARAMIE AVE COMPLAINT FAILED View
DEFECTIVE METER EQUIPMENT REPLACE DEFECTIVE AND ALTERED METER BOX IN BASEMENT AREA WITH EXPOSED LIVE PACKS- DANGEROUS AND HAZARDOUS CONDITION * 1059 N LARAMIE AVE COMPLAINT FAILED View
WORKING SPACE PROVIDE PROPER CLEARANCES FOR METAL BANK AND ELECTRICAL PANELS OBSTRUCTED BY CAST IRON DRAIN PIPE- 1059 N LARAMIE AVE COMPLAINT FAILED View
CONTINUITY OF RACEWAY PROVIDE GROUND CONTINUITY FOR 1/2 CONDUIT RUN AT NORTH EXTERIOR AREA OF BUILDING, ROMEX IN BASEMENT AREA, PIPE APART OF CONDUIT FITTINGS AND BOXES THROUGH OUT BASEMENT AREA-DANGEROUS AND HAZARDOUS CONDITION* 1059 N LARAMIE AVE COMPLAINT FAILED View
INSTALL COVERS PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION BOXES THROUGH OUT BASEMENT AREA WITH EXPOSE WIRES-DANGEROUS AND HAZARDOUS CONDITION* 1059 N LARAMIE AVE COMPLAINT FAILED View
INSTALL ILLUMINATION PROVIDE ILLUMINATION THROUGH OUT ALL BASEMENT AREA'S- 1059 N LARAMIE AVE COMPLAINT FAILED View
ARMORED CABLE REMOVE ALL DEFECTIVE AND EXCESSIVE USE OF ARMOURED CABLE THROUGH OUT BASEMENT AREA'S- 1059 N LARAMIE AVE COMPLAINT FAILED View
CORRODED CONDUIT & EQUIP REPLACE ALL RUSTED CORRODED METER BANK, PANELS CONDUIT RUNS THROUGH OUT BASEMENT AREA'S, REAR PORCH AREA'S. AND NORTH EXTERIOR AREA OF BUILDING- 1059 N LARAMIE AVE COMPLAINT FAILED View
PROVIDE WEATHER PROOF BOXES, LITES, FITTINGS AND APPROVED RACEWAYS FOR FRONT EXTERIOR LITES AND REAR PORCH AREA'S- 18-27-110.11 1059 N LARAMIE AVE COMPLAINT FAILED View
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGH OUT UNITS 5153 2E, 2W, 1E 1059 N LARAMIE AVE COMPLAINT FAILED View
NO PERMIT WIRING OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CONNECT VIOLATION AND FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED WITHOUT PLANS AND PERMITS UNITS 5153-2E, 2W, 1E 1059 N LARAMIE AVE COMPLAINT FAILED View
STRUCTURAL MEMBER, PIER BLOCK REPAIR SOUTH AND EAST WALK ACCORDING TO ENGINEERS REPORT AND ANY REPAIRS TO FLOOR SYSTEM 1059 N LARAMIE AVE COMPLAINT FAILED View
INSTALL FIXTURES PROPERLY SECOND FLOOR EAST TUB SPOUT TOO FAR AWAY FROM WALL 1059 N LARAMIE AVE COMPLAINT FAILED View
SECURE RACEWAY PROPERLY SUPPORT ALL JUNCTION BOXES AND CONDUIT RUNS THROUGH OUT ALL BASEMENT AREA'S- 1059 N LARAMIE AVE COMPLAINT FAILED View
1-HR HEATING PLANT ENCLOSURE OPEN STUDS OBSERVED IN HEATING PLANT ROOMS 5153 2E, 5153 2W NO HEATING PLANT ENCLOSURE IN THE BASEMENT AREA 1059 N LARAMIE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE SECOND FLOOR- TUB CHIPPED, REPAIR OR REPLACE 1059 N LARAMIE AVE COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK PULL A PLUMBING PERMIT 1059 N LARAMIE AVE COMPLAINT FAILED View
ENGAG LIC & BOND PLMBNG CNTRC HIRE A LICENSED PLUMBING CONTRACTOR 1059 N LARAMIE AVE COMPLAINT FAILED View
PROPER MATRL WATER SUPPLY PIPE SECOND FLOOR EAST LAVATORY-FLEX WATER SUPPLIES, REPLACE WITH COPPER SUPPLIES 1059 N LARAMIE AVE COMPLAINT FAILED View
DEFECTIVE DISTRIBUTION PROVIDE PROPER TYPE COVER FOR OPEN PANEL WITH EXPOSE LIVE PACKS DANGEROUS AND HAZARDOUS CONDITION* 1059 N LARAMIE AVE COMPLAINT FAILED View