Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
NO PERMIT AWNING SIGN | TWO (2) AWNING SIGN READS "DTA DEVELOPMENT AND CONSTRUCTION INC SIZE OF AWNING APPROXIMATELY 4' X 20' AND 4' X 4 ON THOMAS STREET | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | OPEN JOISTS OBSERVED THROUGH OUT BASEMENT AREA | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | SECOND FLOOR- TUB SPOUT AWAY FROM WALL | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION FOR ALL KITCHEN COUNTERTOP AREA'S, BATHROOM AND LAUNDRY AREA'S- 18-27-210.8 | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO 1ST FLOOR COMMERCIAL | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | FURNACES OUT OF SERVICE AT TIME OF INSPECTION 1E 5153, 2E 5153, 2W 5153 | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | MISSING SMOKE DETECTORS THROUGH OUR BUILDING | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTORS THROUGH OUT BUILDING | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | USING COOKING STOVE AS HEATING DEVICE THROUGH OUT BUILDING | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | PROVIDE ENGINEERS REPORT ON STRUCTURAL INTEGRITY OF SOUTH AND EAST WALL (STRESS FRACTURES) ALSO FLOOR SYSTEM IT SUPPORTS | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
PARAPET & COPING | REPAIR SOUTH AND EAST PARAPETS SEVERELY DETERIORATED, PERMIT REQUIRED FOR REBUILDING PARAPETS | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH PORCH WITH FOLLOWING DEFECTS, (1) UNVERIFIED FOOTING, JOIST PULLING AWAY FROM WALL DUE TO WALL FRACTURES, OVERSIZED RISERS, UNDERSIZE THREADS. ALL SECTIONS JUST NAILED, PLANS AND PERMITS REQUIRED FOR REPLACEMENT OF PORCH | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
UNINTERRUPTED EXIT AT GRADE | ONLY ONE MEANS OF EGRESS FROM 2ND FLOOR DUE TO SOUTH PORCH IN DANGEROUS AND HAZARDOUS CONDITIONS | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | STAIRS AT 5153 LOOSE THREADS AND RISERS, MOVE UNDER LOAD PLANS AND PERMITS REQUIRED TO FIX | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | CEILING AND WALLS 2W 5153 WATER DAMAGED CEILING IN KITCHEN READY TO CAVE IN | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPAIR DOOR, INT. | HOLE IN BATHROOM DOOR 1E 5153 | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
CONTRARY TO ORIGINAL PLAN | SOUTH PORCH PARTIALLY ENCLOSED WITH 8 INCH C.M.U. CONCRETE BLOCK | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | FIRST FLOOR EAST APARTMENT+2ND FLOOR, EAST+WEST UNITS KITCHEN SINK-REPLACE CORRIGATED TUBING USED FOR SINK TRAP WASTE AND INSTALL APPROVED MATERIAL | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | FIRST FLOOR EAST APARTMENT+2ND FLOOR,EAST+WEST UNITS KITCHEN SINK, LAVATORY AND TOILET, REPLACE FLEX WATER SUPPLIES WITH COPPER SUPPLIES | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | SECOND FLOOR-TUB FAUCET DRIPPING, REPAIR OR REPLACE | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR FOR ALL VIOLATION CORRECTIONS | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | SECOND FLOOR EAST LAVATORY- FLEX WASTE PIPE, REPLACE WITH RIGID TUBING | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | SECOND FLOOR EAST KITCHEN SINK-FLEX WASTE PIPE, REPLACE WITH RIGID TUBING | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | SECOND FLOOR EAST KITCHEN SINK-FLEX WATER SUPPLIES, REPLACE WITH COPPER SUPPLIES | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | 5153 W THOMAS SECOND FLOOR WEST-KITCHEN SINK-REPLACE FLEX WATER SUPPLIES WITH COPPER SUPPLIES | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | 5153 W THOMAS KITCHEN SINK WASTE REPLACE CORRIGATED WASTE PIPE WITH RIGID TUBING | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | 5153 W THOMAS TUB FAUCET DRIPPING, REPAIR OR REPLACE | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | 5153 W THOMAS TUB SURFACE IS CHIPPED IN MULTIPLE LOCATIONS, REPAIR OR REPLACE | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | FIRST FLOOR EAST- KITCHEN FLOOR EAST- FLEX WASTE, REPLACE WITH RIGID TUBING | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | FIRST FLOOR EAST- KITCHEN SINK -FLEX WATER, REPIPE WITH COPPER SUPPLIES | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
DEFECTIVE LIGHTING SERVICE | REPLACE DEFECTIVE SERVICE DISCONNECT THAT HAS SPLICE SERVICE CONDUCTORS WITHOUT OVER CURRENT PROTECTION DEVICE - DANGEROUS AND HAZARDOUS * | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE DEFECTIVE AND ALTERED METER BOX IN BASEMENT AREA WITH EXPOSED LIVE PACKS- DANGEROUS AND HAZARDOUS CONDITION * | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
WORKING SPACE | PROVIDE PROPER CLEARANCES FOR METAL BANK AND ELECTRICAL PANELS OBSTRUCTED BY CAST IRON DRAIN PIPE- | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR 1/2 CONDUIT RUN AT NORTH EXTERIOR AREA OF BUILDING, ROMEX IN BASEMENT AREA, PIPE APART OF CONDUIT FITTINGS AND BOXES THROUGH OUT BASEMENT AREA-DANGEROUS AND HAZARDOUS CONDITION* | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
INSTALL COVERS | PROVIDE PROPER TYPE COVERS FOR OPEN JUNCTION BOXES THROUGH OUT BASEMENT AREA WITH EXPOSE WIRES-DANGEROUS AND HAZARDOUS CONDITION* | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | PROVIDE ILLUMINATION THROUGH OUT ALL BASEMENT AREA'S- | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
ARMORED CABLE | REMOVE ALL DEFECTIVE AND EXCESSIVE USE OF ARMOURED CABLE THROUGH OUT BASEMENT AREA'S- | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
CORRODED CONDUIT & EQUIP | REPLACE ALL RUSTED CORRODED METER BANK, PANELS CONDUIT RUNS THROUGH OUT BASEMENT AREA'S, REAR PORCH AREA'S. AND NORTH EXTERIOR AREA OF BUILDING- | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROVIDE WEATHER PROOF BOXES, LITES, FITTINGS AND APPROVED RACEWAYS FOR FRONT EXTERIOR LITES AND REAR PORCH AREA'S- 18-27-110.11 | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View | |
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED THROUGH OUT UNITS 5153 2E, 2W, 1E | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View | |
NO PERMIT WIRING | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CONNECT VIOLATION AND FOR INSTALLATION OF ELECTRICAL CONDUIT BOXES WIRING DEVICES AND ELECTRICAL EQUIPMENT INSTALLED WITHOUT PLANS AND PERMITS UNITS 5153-2E, 2W, 1E | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
STRUCTURAL MEMBER, PIER BLOCK | REPAIR SOUTH AND EAST WALK ACCORDING TO ENGINEERS REPORT AND ANY REPAIRS TO FLOOR SYSTEM | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
INSTALL FIXTURES PROPERLY | SECOND FLOOR EAST TUB SPOUT TOO FAR AWAY FROM WALL | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SUPPORT ALL JUNCTION BOXES AND CONDUIT RUNS THROUGH OUT ALL BASEMENT AREA'S- | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | OPEN STUDS OBSERVED IN HEATING PLANT ROOMS 5153 2E, 5153 2W NO HEATING PLANT ENCLOSURE IN THE BASEMENT AREA | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | SECOND FLOOR- TUB CHIPPED, REPAIR OR REPLACE | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | SECOND FLOOR EAST LAVATORY-FLEX WATER SUPPLIES, REPLACE WITH COPPER SUPPLIES | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | PROVIDE PROPER TYPE COVER FOR OPEN PANEL WITH EXPOSE LIVE PACKS DANGEROUS AND HAZARDOUS CONDITION* | 1059 N LARAMIE AVE | COMPLAINT | FAILED | View |