Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:06 PM
PIN: 20272120330000
Property Address: 7218 S CHAMPLAIN AVE
City - Zip: CHICAGO - 60619
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70030
2023 Tax District: 70001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 8 Violations
Violation Inspector Comments Address Category Status View
HEAT UNIT ADEQUATELY 2 FRONT 62 DEGREES 7218 S CHAMPLAIN AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID APARTMENT 2 FRONT 7218 S CHAMPLAIN AVE COMPLAINT FAILED View
SAFE WORKING CONDITIONS 2ND FLOOR 7218 S CHAMPLAIN AVE COMPLAINT FAILED View
REPAIR DEFECTIVE FOUNDATION REAR RETAINING WALLS - ERODED CONCRETE. 7218 S CHAMPLAIN AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR REARB EXTERIOR STAIRS, GRADE TO BASEMENT - MISSING GUARDRAILS. 7218 S CHAMPLAIN AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR TWO STORY WOOD PORCH: COLUMNS ERECTED ON TOP OF CONCRETE BASES, FOUNDATION STATUS UNKNOWN.; CENTER COLUMN IS SCABBED AT BEAM CONNECTION.; COLUMNS HALF LAP SPLICCES ARE ONLY 10".; COLUMN BEAM NOTCH IS BELOW RIM JOIST NOTCH.; UNDERSIZED 6"X6" BEAMS SPAN 7'-7".; UNDERSIZED 2"X8" DECK JOISTS SPAN 9'-9".; GUARDRAILS ARE ONLY 32-1/2" HIGH, PICKETS LOWER ENDS ARE FASTENED TO RIM JOIST.; TREADS ARE ONLY 9-1/4" DEEP.; RIM JOISTS, STRINGERS AND RAILING POSTS ARE FASTENED WITH NAILS ONLY.; PLANS AND PERMIT ARE REQUIRED FOR PORCH REPAIRS. 7218 S CHAMPLAIN AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - MISSING OWNER'S ID. SIGN. 7218 S CHAMPLAIN AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. 7218 S CHAMPLAIN AVE COMPLAINT FAILED View