Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 5:02 PM
PIN: 20113240140000
Property Address: 5427 S UNIVERSITY AVE
City - Zip: CHICAGO - 60615
2023 Property Class: 315
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70020
2023 Tax District: 70131
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 9 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - UNVERIFIED CONDITIONS , OCCUPANCY AND DETECTORS . 5427 S UNIVERSITY AVE PERIODIC FAILED View
MAINTAIN WINDOW EAST AND NORTH ELEVATION , WOOD WINDOW FRAMES ROTTED WITH FLAKING PAINT . 5427 S UNIVERSITY AVE PERIODIC FAILED View
REPAIR WINDOW SILLS EAST AND NORTH ELEVATION , LIMESTONE WINDOW SILLS , OPEN MORTAR JOINTS BETWEEN STONES . 5427 S UNIVERSITY AVE PERIODIC FAILED View
REPAIR AREAWAY WALL WEST ELEVATION AT SOUTH FRONT , BASEMENT AREAWAY MISSING GUARDRAILS , CONCRETE FOUNDATION WALLS LEANING AND DISPLACED . 5427 S UNIVERSITY AVE PERIODIC FAILED View
SERVICE WALK, PASSAGE, AREAWAY WEST ELEVATION AT SOUTH FRONT , SERVICE WALK DISPLACED CONCRETE . 5427 S UNIVERSITY AVE PERIODIC FAILED View
REPAIR FENCE FRONT IRON COURTYARD FENCE , RUSTED WITH FLAKING PAINT . 5427 S UNIVERSITY AVE PERIODIC FAILED View
REPAIR ROOF SOUTH PORCH ROOFS , ROTTED BEAMS , RAFTERS AND DECKING WITH FLAKING PAINT . 5427 S UNIVERSITY AVE PERIODIC FAILED View
PROVIDE GUARD RAIL 42 IN HIGH SOUTH BASEMENT AREAWAYS , GUARDRAILS UNDERSIZED WITH HORIZONTAL MEMBERS MISSING ALL PICKETS . 5427 S UNIVERSITY AVE PERIODIC FAILED View
REPAIR PORCH SYSTEM TWO SOUTH THREE STORY WOOD PORCHES REQUIRE PLANS AND PERMITS , ALL MEMBERS WORN AND WEATHERED FINISH . UNKNOWN FOUNDATION STATUS . UPRIGHTS DOUBLE NOTCHED WITH INSUFFICIENT LAP CONNECTIONS . BEAMS OVERSPANNED .RIM JOIST AND BEAMS ONLY NAILED TO COLUMNS FLOOR JOIST OVERSPANNED AND UNDERSIZED . NO STAIR HEADER SUPPORT WITH STAIR TREADS ONLY NINE INCHES WIDE . ALL HANDRAILS AND GUARDRAILS UNDERSIZED AND OVERSPANNED , ONLY NAILED . 5427 S UNIVERSITY AVE PERIODIC FAILED View