The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OBSTRUCTIONS IN EXIT WAY | SR 08 00167971 EXTERIOR DOOR BURGLAR BARS | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | EXTERIOR DOOR FRAMES ROTTED | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EXTERIOR DOORS ROTTED | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR EAVES | EAVES ROTTED | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | UNDER PORCH AREA JUNK AND DEBRIS | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | WINDOW FRAMES ROTTED | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
RAT STOP AROUND EXTERIOR | BUILDING AREA RAT HOLES | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | WINDOW PANES BROKEN | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | EAST ELVATION / 1 STORY PORCH - 4X4 COLUMNS FOOTING CRACKED.LEDGER BOARD NAILED . JOIST NAILED. 2X6 JOIST SPAN 8 FT GUARD RAILS AND STRINGERS NAILED ONLY TO COLUMNS,HEADERS AND WALL WEST ELVATION / EXTERIOR 2 STORY PORCH - COLUMNS NOT ERECTED FULLY ON FOOTING. 6X6 COLUMNS 1/2 LAP 12 INCHES WITH 2 BOLTS. STRINGERS AND RISER SCAB JOIST NAILED TO HEADERS. GUARD RAILS LOOSE AND OVER SPAN .GUARD RAILS AND STRINGERS NAILED ONLY TO COLUMNS,HEADERS AND WALL .PLANS AND PERMIT REQUIRED FOR REPAIR TO REAR PORCH OR REPLACE | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELVATION / EXTERIOR STAIR - BASEMENT TO GRADE MISSING PICKETS. | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INSP CONDIATIONS AND DETECTORS . | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | SOUTH ELVATION / CHIMNEY CAP - MISSING . | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST ELVATION / WINDOW SILL - OPEN MORTAR JOINT. | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | SOUTH ELVATION / EXTERIOR DOOR - ROTTED | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | WEST ELVATION / GUARD RAIL - MISSING AT GRADE | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING, NO RESPONSE TO VERIFY DETECTORS AND COMPLAINT OF BED BUG INFESTATION IN FIRST FLOOR APARTMENT. | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | EXTENSION CORD RUNNING FROM 1ST TO 2ND AT SOUTH WINDOWS. | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING- NO ENTRY UNABLE TO VERIFY DETECTORS AND CONDITION. | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH STRINGERS NAILED ONLY, 1ST LOOSE RAIL AND GUARDRAILS 36" INCHES PERMIT REQUIRED FOR REPAIR. | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; STRINGERS INADEQUATELY SUPPORTED AT COLUMNS; LOOSE SPINDLE AT HANDRAIL FROM 1ST TO 2ND FLOOR; LOOSE RAIL AT 1ST FLOOR; RAIL HEIGHT ONLY 36 1/4"; LOOSE WINDER FROM 1ST TO 2ND FLOOR; CRACKED, SPLINTERED RISERS AND AND WINDERS THROUGHOUT; SCUTTLE PANEL MISSING AT 2ND FLOOR. PERMIT REQUIRED TO REPAIR REAR PORCH. | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | FRONT ENTRANCE - EXTERIOR LIGHT FIXTURE - HANGING; UNSECURED | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR SCREENS | 1ST FLOOR/WINDOW SCREENS - TORN | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND CONDITIONS. | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
PROVIDE DEADLOCK FOR ENTRANCE | SIDE ENTRY DOOR - DEADBOLT LOCK MISSING | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | GUARDRAIL MISSING AT GRADE FOR BASEMENT AREAWAY | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | REAR ENTRY DOORS - ROTTING TRIM; PAINT PEELING | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | EAST -1ST FLOOR/FRONT ENTRY DOOR - HOLE IN GLASS LITE;SOUTH/SIDE ENTRY DOOR - DE-LAMINATING | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | NEW FENCE - 68 3/4" IN HEIGHT; NO PERMIT OBTAINED | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | EAST - FRONT ENTRY SCREEN DOORS/1ST FLOOR - SCREEN MISSING AT ONE DOOR; BROKEN CLOSER AT OTHER;WEST/2ND FLOOR - TORN SCREEN | 6712 S WABASH AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | 1ST FLOOR - FURNITURE, GRILL ON REAR PORCH DECK OBSTRUCTING EXITWAY | 6712 S WABASH AVE | COMPLAINT | FAILED | View |