Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING / ENTRY REFUSED,UNVERIFIED DETECTORS (OCCUPANCY AND CONDITIONS). | 1011 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION / FRONT 1 STORY WOODEN PORCH.FRONT PORCH ROOF COLUMNS-LEANING OUT OF PLUMB.CONCRETE BLOCK COULMNS WITH WASHED OUT MORTAR,JOISTS ARE 2X8,DRY-ROTTED AND SPAN 20 FEET.STRINGERS ARE ONLY FACE NAILED AT TOP CONNECTION,TREADS ARE SPLITTING,RISERS NOT UNIFORM HEIGHT,RANGING FROM 5 INCHES TO 8 INCHES.RAILINGS ARE WORN AND ONLY 32 INCHES IN HEIGHT.EAST ELEVATION / NORTH WOODEN PORCH,GRADE TO 1ST FLOOR.2X4 COLUMNS SET ON CONCRETE BLOCKS-FOUNDATION STATUS UNKNOWN.JOISTS ONLY FACE NAILED TO SUPPORTS.HAND RAIL MISSING ON SOUTH ELEVATION.RAILINGS ROTTED AND ONLY 32 INCHES IN HEIGHT.SOUTH ELEVATION / EXTERIOR 2 STORY WOODEN PORCH FROM GRADE TO ATTIC.2X4 AND 4X4 COLUMNS SET ON CONCRETE.FOUNDATION STATUS UNKNOWN.JOISTS ARE 2X8 AND FACE NAILED TO SUPPORTS.STRINGERS ARE ROTTED AND ONLY FACE NAILED TO SUPPORTS.RISERS-NOT UNIFORM IN HEIGHT,RANGING FRON 5 INCHES TO 8 INCHES,TREADS ARE ROTTED.RAILINGS ARE LOOSE AND PULLING AND ONLY 32 INCHES IN HEIGHT.DECKING IS ROTTED.PLANS AND PERMIT REQUIRED FOR REPAIRS OF FRONT AND REAR PORCHES. | 1011 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING HAND RAIL. | 1011 N KARLOV AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING GUARD RAILS. | 1011 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION / FRONT 1 STORY WOODEN PORCH.FRONT PORCH ROOF COLUMNS-LEANING OUT OF PLUMB.CONCRETE BLOCK COULMNS WITH WASHED OUT MORTAR,JOISTS ARE 2X8,DRY-ROTTED AND SPAN 20 FEET.STRINGERS ARE ONLY FACE NAILED AT TOP CONNECTION,TREADS ARE SPLITTING,RISERS NOT UNIFORM HEIGHT,RANGING FROM 5 INCHES TO 8 INCHES.RAILINGS ARE WORN AND ONLY 32 INCHES IN HEIGHT.EAST ELEVATION / NORTH WOODEN PORCH,GRADE TO 1ST FLOOR.2X4 COLUMNS SET ON CONCRETE BLOCKS-FOUNDATION STATUS UNKNOWN.JOISTS ONLY FACE NAILED TO SUPPORTS.HAND RAIL MISSING ON SOUTH ELEVATION.RAILINGS ROTTED AND ONLY 32 INCHES IN HEIGHT.SOUTH ELEVATION / EXTERIOR 2 STORY WOODEN PORCH FROM GRADE TO ATTIC.2X4 AND 4X4 COLUMNS SET ON CONCRETE.FOUNDATION STATUS UNKNOWN.JOISTS ARE 2X8 AND FACE NAILED TO SUPPORTS.STRINGERS ARE ROTTED AND ONLY FACE NAILED TO SUPPORTS.RISERS-NOT UNIFORM IN HEIGHT,RANGING FRON 5 INCHES TO 8 INCHES,TREADS ARE ROTTED.RAILINGS ARE LOOSE AND PULLING AND ONLY 32 INCHES IN HEIGHT.DECKING IS ROTTED.PLANS AND PERMIT REQUIRED FOR REPAIRS OF FRONT AND REAR PORCHES. | 1011 N KARLOV AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING HAND RAIL. | 1011 N KARLOV AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING / ENTRY REFUSED,UNVERIFIED DETECTORS (OCCUPANCY AND CONDITIONS). | 1011 N KARLOV AVE | COMPLAINT | PASSED | View |
REPAIR ROOF | REAR ELEVATION / 1ST FLOOR ENCLOSED PORCH ROOF-BLUE TARP COVERING ROOF. | 1011 N KARLOV AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION / 1ST FLOOR WINDOW-BROKEN PANE. | 1011 N KARLOV AVE | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING GUARD RAILS. | 1011 N KARLOV AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. | 1011 N KARLOV AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE ATTIC WITHOUT A PERMIT. | 1011 N KARLOV AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION / 1ST FLOOR WINDOW-BROKEN PANE. | 1011 N KARLOV AVE | COMPLAINT | FAILED | View |
REPAIR ROOF | REAR ELEVATION / 1ST FLOOR ENCLOSED PORCH ROOF-BLUE TARP COVERING ROOF. | 1011 N KARLOV AVE | COMPLAINT | FAILED | View |