Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 6:17 AM
PIN: 16034140170000
Property Address: 1011 N KARLOV AVE
City - Zip: CHICAGO - 60651
2023 Property Class: 203
2023 Township: 77 - West Chicago
2023 Neighborhood: 77020
2023 Tax District: 77162
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 14 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING / ENTRY REFUSED,UNVERIFIED DETECTORS (OCCUPANCY AND CONDITIONS). 1011 N KARLOV AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION / FRONT 1 STORY WOODEN PORCH.FRONT PORCH ROOF COLUMNS-LEANING OUT OF PLUMB.CONCRETE BLOCK COULMNS WITH WASHED OUT MORTAR,JOISTS ARE 2X8,DRY-ROTTED AND SPAN 20 FEET.STRINGERS ARE ONLY FACE NAILED AT TOP CONNECTION,TREADS ARE SPLITTING,RISERS NOT UNIFORM HEIGHT,RANGING FROM 5 INCHES TO 8 INCHES.RAILINGS ARE WORN AND ONLY 32 INCHES IN HEIGHT.EAST ELEVATION / NORTH WOODEN PORCH,GRADE TO 1ST FLOOR.2X4 COLUMNS SET ON CONCRETE BLOCKS-FOUNDATION STATUS UNKNOWN.JOISTS ONLY FACE NAILED TO SUPPORTS.HAND RAIL MISSING ON SOUTH ELEVATION.RAILINGS ROTTED AND ONLY 32 INCHES IN HEIGHT.SOUTH ELEVATION / EXTERIOR 2 STORY WOODEN PORCH FROM GRADE TO ATTIC.2X4 AND 4X4 COLUMNS SET ON CONCRETE.FOUNDATION STATUS UNKNOWN.JOISTS ARE 2X8 AND FACE NAILED TO SUPPORTS.STRINGERS ARE ROTTED AND ONLY FACE NAILED TO SUPPORTS.RISERS-NOT UNIFORM IN HEIGHT,RANGING FRON 5 INCHES TO 8 INCHES,TREADS ARE ROTTED.RAILINGS ARE LOOSE AND PULLING AND ONLY 32 INCHES IN HEIGHT.DECKING IS ROTTED.PLANS AND PERMIT REQUIRED FOR REPAIRS OF FRONT AND REAR PORCHES. 1011 N KARLOV AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING HAND RAIL. 1011 N KARLOV AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING GUARD RAILS. 1011 N KARLOV AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM WEST ELEVATION / FRONT 1 STORY WOODEN PORCH.FRONT PORCH ROOF COLUMNS-LEANING OUT OF PLUMB.CONCRETE BLOCK COULMNS WITH WASHED OUT MORTAR,JOISTS ARE 2X8,DRY-ROTTED AND SPAN 20 FEET.STRINGERS ARE ONLY FACE NAILED AT TOP CONNECTION,TREADS ARE SPLITTING,RISERS NOT UNIFORM HEIGHT,RANGING FROM 5 INCHES TO 8 INCHES.RAILINGS ARE WORN AND ONLY 32 INCHES IN HEIGHT.EAST ELEVATION / NORTH WOODEN PORCH,GRADE TO 1ST FLOOR.2X4 COLUMNS SET ON CONCRETE BLOCKS-FOUNDATION STATUS UNKNOWN.JOISTS ONLY FACE NAILED TO SUPPORTS.HAND RAIL MISSING ON SOUTH ELEVATION.RAILINGS ROTTED AND ONLY 32 INCHES IN HEIGHT.SOUTH ELEVATION / EXTERIOR 2 STORY WOODEN PORCH FROM GRADE TO ATTIC.2X4 AND 4X4 COLUMNS SET ON CONCRETE.FOUNDATION STATUS UNKNOWN.JOISTS ARE 2X8 AND FACE NAILED TO SUPPORTS.STRINGERS ARE ROTTED AND ONLY FACE NAILED TO SUPPORTS.RISERS-NOT UNIFORM IN HEIGHT,RANGING FRON 5 INCHES TO 8 INCHES,TREADS ARE ROTTED.RAILINGS ARE LOOSE AND PULLING AND ONLY 32 INCHES IN HEIGHT.DECKING IS ROTTED.PLANS AND PERMIT REQUIRED FOR REPAIRS OF FRONT AND REAR PORCHES. 1011 N KARLOV AVE COMPLAINT PASSED View
REPAIR EXTERIOR STAIR REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING HAND RAIL. 1011 N KARLOV AVE COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING / ENTRY REFUSED,UNVERIFIED DETECTORS (OCCUPANCY AND CONDITIONS). 1011 N KARLOV AVE COMPLAINT PASSED View
REPAIR ROOF REAR ELEVATION / 1ST FLOOR ENCLOSED PORCH ROOF-BLUE TARP COVERING ROOF. 1011 N KARLOV AVE COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS EAST ELEVATION / 1ST FLOOR WINDOW-BROKEN PANE. 1011 N KARLOV AVE COMPLAINT PASSED View
PROVIDE GUARD RAIL 42 IN HIGH REAR ELEVATION / EXTERIOR STAIRS,GRADE TO BASEMENT-MISSING GUARD RAILS. 1011 N KARLOV AVE COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO ATTIC OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES. 1011 N KARLOV AVE COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE ATTIC WITHOUT A PERMIT. 1011 N KARLOV AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS EAST ELEVATION / 1ST FLOOR WINDOW-BROKEN PANE. 1011 N KARLOV AVE COMPLAINT FAILED View
REPAIR ROOF REAR ELEVATION / 1ST FLOOR ENCLOSED PORCH ROOF-BLUE TARP COVERING ROOF. 1011 N KARLOV AVE COMPLAINT FAILED View