Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR SKYLIGHT | FRONT INTERIOR STAIRS / SKYLIGHT-CRACKED GLASS. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
REPAIR/REPLACE SMOKE DETECTORS | FRONT INTERIOR STAIRS,3DR FLOOR APARTMENT-SMOKE DETECTOR OUT OF SERVICE AT TIME OF INSPECTION WITH LOW BATTERY. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
ADD RECEPTACLES | 3RD FLOOR APARTMENT,BASEMENT LAUNDRY AREA-EXTENSION CORDS BEING USED. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
REMV OBSTR FROM DRAINAGE SYSTM | 3RD FLOOR APARTMENT/BATHROOM SINK CLOGGED. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
MICE/RODENTS | 3RD FLOOR APARTMENT / KITCHEN AREA-MICE DROPPINGS. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
PROVID SELF CLSING SCREEN DVCE | 3RD FLOOR APARTMENT REAR STORM DOOR-MISSING CLOSER. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
INSTALL SMOKE DETECTORS | BASEMENT BOILER ROOM / MISSING SMOKE DETECTOR. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
CARB MONOX DETECT IN RESID | BASEMENT BOILER ROOM / MISSING CARBON MONOXIDE DETECTOR. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE / EAVES-ROTTED. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION / 3RD FLOOR-SPALLING BRICK,WASHED OUT MORTAR. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
1HR PUB.CORRIDOR IN MULT. D.U. | WEST ELEVATION / PASSAGE AREA WAY CEILING-FOAM PANELS INSTALLED. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT FRONT,1ST,2ND FLOOR APARTMENTS,UNVERIFIED DETECTORS,CONDITIONS. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY WOODEN PORCH.6X6 AND 4X4 COLUMNS ARE BOWED,TWISTED AND OVER NOTCHED SET ON CONCRETE BLOCKS,FOUNDATION STATUS UNKNOWN.2X8 JOISTS ARE FACE NAILED ONLY TO BEAMS.STRINGERS ARE FACE NAILED ONLY TO SUPPORTS,MASONRY NAILED TO BUILDING,TREADS ARE LOOSE AND SPLITTING.RAILINGS ARE LOOSE AND PULLING,TOE NAILED ONLY TO SUPPORTS,MASONRY NAILED TO BUILDING.PLANS AND PERMIT REQUIRED FOR REPAIRS. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
DEFECTIVE OUTLETS | 1ST AND 2ND FLOOR APARTMENTS ALL ROOMS | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
TENANT ACCESS TO SERVICE | ACCESS IS REQUIRED FOR SERVICE DISCONNECT SWITCH'S | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | 1ST FLOOR DINING ROOM | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
RATS | EVIDENT OF RATS. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTOR OUT OF ORDER 2ND. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | 2ND CARBON MONOXIDE DETECTOR OUT OF ORDER. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | WINDOW SCREENS TORN. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRWELL GUARDRAIL 32" HIGH. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | REAR GARAGE ROTTED EAVES, ROOF WORN, NO GUTTER OR DOWNSPOUT. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH COLUMNS INSIDE CONCRETE OR RESTING ON BRICKS, JOISTS MISSING HANGERS, LEDGER MISSING BOLTS, GUARDRAIL AND HANDRAIL VERY LOOSE, 2ND AND 3RD RAILS 36" HIGH, WORN, BROKE AND CRACK TREADS, STRINGERS NAIL, PORCH REQUIRE PLAN AND PERMIT FOR REPAIR. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | GRADE TO 3RD FLOOR / ALL UNITS /UNABLE TO GAIN ENTRY TO INSPECT INTERIOR. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | 3 STORY MASONRY BUILDING ALL ELEVATIONS / GRADE TO 3RD FLOOR /WINDOW SCREENS - MISSING / TORN IN VARIOUS LOCATIONS. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
SUPPORT OUTLET AND JBOX | IN FIRST, SECOND FLOOR UNITS HAVE RECEPTACLES NOT PROPERLY SECURED IN WALL OR BOX | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO INSPECTION OF THIRD FLOOR APARTMENT UNIT. ALLOW FOR INTERIOR INSPECTION | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | BREACH IN PLASTER/DRYWALL CEILING IN BASEMENT AREA. 1 HOUR FIRE SEPARATION REQUIRED THROUGHOUT BASEMENT AREA CEILINGS. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | INSTALL A VACUUM BREAKER HOSE BIB AND REMOVE THE BOILER DRAIN USED FOR HOSE CONNECTION. (18-29-608) SECOND FLOOR | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH AT THE SOUTH ELEVATION NOT PROPERLY CONSTRUCTED AND MISSING COMPONENTS: (A) WORN AND ROTTED TREADS FROM GRADE TO FIRST FLOOR (B) TREADS, STRINGERS, RISERS, AND PICKETS NAILED ONLY MISSING ANGLE BRACKETS (C) 6/6 COLUMNS NOT PROPERLY SPLICED AT SECOND AND THIRD FLOOR LEVELS SPLICE (D) 4/4 COLUMNS SITTING ON CONCRETE SLAB UNABLE TO VERIFY FOOTINGS (E) LEDGERS AT THE FIRST AND SECOND AND THIRD FLOOR LEVELS NOT BOLTED TO BUILDING (F) STRINGERS AT THE FIRST FLOOR LEVEL NOT BOLTED TO PROPERTY (G) MISSING JOIST HANGERS AT THE FIRST SECOND AND THIRD FLOOR LEVELS (H) MISSING A36- BRACES AT LOAD BEARING SUPPORT BEAMS WHERE NEEDED. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROPER PLANS AND PERMITS REQUIRED TO CORRECT ALL VIOLATIONS WITHIN BUT NOT LIMITED TO REAR THREE STORY WOOD CONSTRUCTED PORCH. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTORS AT THE HALLWAY COMMON AREA BEEPING LOW BATTERY, BEEPING LOW BATTERY AT THE SECOND FLOOR LEVEL. DANGEROUS AND HAZARDOUS. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | MISSING CARBON MONOXIDE DETECTOR AT THE SECOND FLOOR LEVEL. DANGEROUS AND HAZARDOUS. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | CEILINGS IN THE BATHROOM AND LIVING ROOM FAILING, BATHROOM CEILING SHOWING SIGNS OF WATER DAMAGE, CEILING IN LIVING ROOM AREA APPROXIMATELY 10/10 TILE LOOSE AND HANGING. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
INDIRECT CONN.FOR WATER SUPPLY | INSTALL AN APPROVED BACK FLOW DEVICE ON THE COLD WATER SUPPLY TO THE BOILER. (18-29-608) | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
PRV DISCHARGE PIPE FROM PRV | INSTALL A METAL PIPE FOR THE RELIEF VALVE DISCHARGE. (18-29-504.7.1) FIRST FLOOR | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
STOP LEAKING WATER | REPAIR TOILET ON THIRD FLOOR LEAKING THROUGH SECOND FLOOR CEILING. (18-29-102.3) | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | REPAIR OR REPLACE FAUCET, RUNNING. (18-29-420.1 & 424) | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REPLACE ALL FLEX WATER SUPPLIES TO TOILETS, LAVATORIES AND KITCHEN SINKS THROUGHOUT ENTIRE BUILDING. (18-29-605) | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE PLBG FIXTURE | REMOVE BROKEN CERAMIC SOAP DISH, RAZOR SHARP EDGE. (18-29-402.1) | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR. (18-29-106.1) | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT. (18-29-106.1) | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
DEFECTIVE LIGHTING SERVICE | REPLACE DETERIORATED, DEFECTIVE SERVICE ENTRANCE CABLE RISER, FEEDER | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLE TO EASE EXTENSION CORD THROUGHOUT THE BASEMENT AREA, LAUNDRY AREA AND IN 1, 2 FLOOR UNITS LIVING ROOM, DINING ROOMS, BEDROOM, KITCHEN AREAS AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR CORRODED CONDUIT WITH BARE WIRES EXPOSED AT REAR PORCH AREA AND IN FIRST SECOND FLOOR UNITS HAVE BARE WIRES AT LIVING ROOM CEILING FAN AREA, ABOVE LAY IN CEILING AREAS IN BEDROOMS AND KITCHEN AREAS DANGEROUS AND HAZARDOUS CONDITION | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPLACE ALL DEFECTIVE AND PAINTED RECEPTACLES THROUGHOUT THE BASEMENT, FIRST, SECOND FLOOR UNITS AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE ALL DEFECTIVE LIGHTS THROUGHOUT THE BASEMENT, FIRST, SECOND FLOOR UNITS AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | PROPERLY SUPPORT ALL CAN LIGHTS ABOVE DROP CEILING AREAS IN BASEMENT, FIRST, SECOND FLOOR AREAS AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
ADD BRANCH CIRCUITS | ADD CIRCUITS TO EASE OVERLOAD USE FROM APPLIANCES IN KITCHEN, LIVING ROOM, BEDROOM AREAS OF FIRST, SECOND FLOOR UNITS AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
SECURE RACEWAY | PROPERLY SUPPORT ALL CONDUIT RUNS THROUGHOUT THE BASEMENT AREA | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GCI PROTECTION FOR ALL KITCHEN COUNTERTOP AREAS, BATHROOM, LAUNDRY AREAS OF BASEMENT, FIRST, SECOND FLOOR UNITS AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING 18-27-570.8 | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
PROVIDE WEATHER PROOF BOXES, LIGHTS, FITTINGS AND APPROVED RACEWAYS FOR REAR PORCH AREAS 18-27-110.11 | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View | |
CLOSET LIGHTS SHALL HAVE A TOTALLY ENCLOSED LAMP TYPE FIXTURE, THROUGHOUT THE FIRST, SECOND FLOOR UNITS AND OTHER TYPICAL UNITS THROUGHOUT THE BUILDING 18-27-410.8 | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View | |
PROVIDE THE REQUIRED DIAGRAM AND LOAD CALCULATIONS FOR SERVICES, FEEDERS AND REQUIRED EQUIPMENT, SERVICE UNDERSIZE FOR BUILDING 18-27-215.5, 18-27-220. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View | |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS 13-12-360. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View | |
STOP/REMOVE NUISANCE | REAR YARD UNDER PORCH,BARBECUE GRILL.WEST ELEVATION / AREA PASSAGE AREA WAY-MOTORCYCLE STORED. | 4209 W JACKSON BLVD | COMPLAINT | CLOSED | View |
REPAIR INTERIOR WALLS/CEILING | STAIRWELL WALL PEELING PAINT AND BUCKLING.AT 2ND CEILING BEDROOM TILES MISSING, BATHROOM CEILING OVER TOILET LEAKING AND WATER DAMAGE. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
ROACHES | EVIDENT OF ROACHES. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | SECOND FLOOR TENANT USING STOVE FOR ADDITIONAL HEAT SOURCE. | 4209 W JACKSON BLVD | COMPLAINT | FAILED | View |
OPEN | 4209 W JACKSON BLVD | PERMIT | PASSED | View |