The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
VACANT BUILDING - REGISTER | OCCUPIED PER KEITH LONG (OWNER) | 1941 W GARFIELD BLVD | COMPLAINT | CLOSED | View |
PERMIT REQUIRED - CONTRACTOR | REPLACED MASONRY CHIMNEY.REPLACED BRICKS ON EXTERIOR WALLS. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | PERMIT FEE AND PENALTY TO BE ASSESSED FOR WORK DONE WITHOUT A PERMITSECTION 13-12-080, 13-32-035. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | 2ND FLOOR AND 1ST FLOOR APARTMENTS, NO ENTRY. UNABLE TO VERIFY DETECTORS, CONDITIONS AND OCCUPANCY. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S IDENTIFICATION SIGN MISSING. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR LINTELS | NORTH ELEVATION / MULTIPLE LOCATIONS AT WINDOW OPENINGS FACING NORTH AND EAST. - RUSTED AND SAGGING LINTELS WITH GAPS ABOVE. PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF STEEL LINTELS.NORTH ELEVATION / EXTERIOR WALL OPENINGS FACING NORTH AND WEST - SAGGING AND FRACTURED CONCRETE PARGE COATING AT BASE OF STEEL LINTELS.PLANS AND PERMIT REQUIRED FOR REPAIR / REPLACEMENT OF STEEL LINTELS.SOUTH ELEVATION / GARAGE OVERHEAD DOOR OPENING FACING SOUTH - RUSTED AND SAGGING LINTEL WITH GAPS ABOVE.PLANS AND PERMIT REQUIRED FOR REPLACEMENT OF STEEL LINTEL. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SOUTH ELEVATION / TWO STORY ENCLOSED PORCH HAS BEEN EXTENSIVELY REPAIRED, NO PERMIT OBTAINED.PLANS AND PERMIT ARE NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL.BASEMENT DWELLING UNIT / SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, OR RESTORE THE BUILDING TO THE ORGINIAL STATE.NORTH ELEVATION / STAIRS FROM GRADE TO BASEMENT BUILT, NO PERMIT OBTAINED. PLANS AND PERMIT ARE NOW REQUIRED. SUBJECT TO FIELD INSPECTION AND APPROVAL. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PARTITIONS, N/L/B - BASEMENT | BASEMENT DWELLING UNIT / MULTIPLE LOCATIONS - UNFINISHED PARTITIONS THROUGHOUT WITH SECTIONS OF GYPSUM WALLBOARD ONLY ATTACHED TO 1 SIDE OF 3-1/2 INCH STUDS. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
INSTALL COVERS | BASEMENT DWELLING UNIT AND TWO STORY ENCLOSED PORCH / MULTIPLE LOCATIONS - MISSING COVER AT RECEPTABLE AND JUNCTION BOXES. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | EAST ELEVATION / 1ST FLOOR - WINDOW BOARDED OVER. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR FENCE | EAST ELEVATION / FENCE - LOOSE, ROTTING AND LEANING SECTIONS. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE / MULTIPLE LOCATIONS - WASHED OUT MORTAR JOINTS, SPALLING BRICKS, FRACTURED BRICKS MISSING BRICKS. BULGING AND SAGGING SECTIONS OF MASONRY.PERMIT REQUIRED FOR MASONRY REPAIRS TO GARAGE. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | SOUTH ELEVATION / TWO STORY ENCLOSED PORCH - FRAMING MEMBER ENCLOSED AT MOST LOCATIONS, NOT ABLE TO VERIFY. 2X6 FLOOR JOISTS AT 1ST FLOOR FRAMING DEFICIENTLY SPANNING 12 FEET. STAIR FLIGHTS SLOPING THROUGHOUT. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | NORTH ELEVATION / STAIR FROM GRADE TO BASEMENT - MISSING HANDRAIL.NORTH ELEVATION / STAIRS FROM GRADE TO COMMON ENTRY FOR 1ST AND 2ND FLOOR - MISSING TILES. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | NORTH ELEVATION / STAIR FROM GRADE TO BASEMENT GUARDRAIL - MISSING. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PRV FLOOR DRAIN WITH METAL STR | NORTH ELEVATION / BASEMENT LANDING FLOOR DRAIN COVER - MISSING. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
PARAPET | WEST AND EAST ELEVATIONS / MULTIPLE LOCATIONS - WASHED OUT MORTAR JOINTS, SPALLING BRICKS, LOOSE BRICKS, MISSING BRICKS.PERMIT ONLY REQUIRED FOR MASONRY REPAIRS. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | NORTH ELEVATION / GATE ADJACENT TO PUBLIC SIDEWALK - CHAINED AND PADLOCKED. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | NORTH ELEVATION / COMMON ENTRY DOOR - BOARDED OVER WITH PLYWOOOD, CHAINED AND LOCKED. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION / MASONRY WING WALL FOR STAIRS FROM GRADE TO COMMON ENTRY FOR 1ST AND 2ND FLOORS - STEPS FRACTURES. WASHED OUT MORTAR JOINTS. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | SOUTH ELEVATION ENCLOSED TWO STORY PORCH AND BASEMENT DWELLING UNIT / MULTIPLE LOCATIONS - LOOSE AND HANGING LIGHT FIXTURES. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
LIGHT AND VENT | BASEMENT DWELLING UNIT WINDOWS LOCATED ENTIRELY AT GRADE LEVEL. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 1941 W GARFIELD BLVD | COMPLAINT | FAILED | View |