REPAIR EAVES | NORTH AND SOUTH ELEVATIONS - ROTTING EAVES. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR GUTTER | NORTH AND SOUTH ELEVATIONS - SPLITTING GUTTERS. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | WEST ELEVATION / FRONT PORCH - 2X6 FLOOR JOISTS SPANNING 10' ANCHORED TO BEAMS WITH NAILS ONLY. PERMIT REQUIRED FOR PORCH REPAIR.EAST ELEVATON / REAR PORCH - COLUMNS AND POST ON CONCRETE SLAB, GRADE AND DEFECTIVE RETAINING WALL. FOUNDATION STATUS UNKNOWN. ENCLOSED PORCH FRAMING NOT VISIBLE DUE TO ADDITION OF PLYWOOD AT UNDERSIDE OF 1ST FLOOR FRAMING. UPPER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT BEAM AND POSTS WITH COMMON NAILS ONLY. PERMIT REQUIRED FOR PORCH REPAIRS. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION / STAIRS FROM GRADE TO 1ST FLOOR - UPPERENDS OF STRINGERS INADEQUATELY SUPPORTED POST AND FLOOR JOISTS WITH COMMON NAILS ONLY.EAST ELEVATION / STAIRS FROM GRADE TO 1ST FLOOR - CRACKED AND MISSING SECTIONS OF CONCRETE TREADS AND RISERS. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | NORTH, SOUTH AND EAST ELEVATIONS / MULTIPLE LOCATIONS - WASHED OUT MORTAR JOINTS. MISSING MORTAR HAS BEEN INADEQUATELY INFILL WITH EXPANDING FOAM.SOUTH ELEVATIONS / 2ND FLOOR DORMER - DETEACHED, TORN AND MISSING SECTIONS OF VINYL SIDING. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR ROOF | SOUTH ELEVATION / RAFTERS ADJACENT TO 2ND FLOOR DORMER - SAGGING AT MULTIPLE LOCATIONS. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO 1ST FLOOR REAR PORCH OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | THROUGHOUT 1ST AND 2ND FLOORS - MOISTURE DAMAGE AT WALLS AND CEILINGS. REMEDIATION EFFORTS OF PATCHING WALLBOARDS DO NOT RESOLVE MOISTURE PENETRATION ISSUE. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | ALL ELEVATIONS / 1ST AND 2ND FLOOR - AIR SEEPAGE THROUGH WINDOWS. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | BASEMENT 6X6 BEAM ROTTING AND DAMAGED BY TERMITE, SAGGING. BRACING ADDED AS REMEDIATION ALSO SAGGING AT MIDSPAN. SUBMIT STRUCTURAL ENGINEERS REPORT ON STABILITY OF 1ST FLOOR STRUCTURE. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FOUNDATION | BASEMENT FOUNDATION WALLS - MOISTURE PENETRATION THROUGHOUT. WALLS HAVE BEEN PAINTED TO COVER MOISTURE STAINS,STILL VISIBLE, AND EFFLORESCENCE, ALSO STILL VISIBLE. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | BASEMENT INTERIOR STAIRWAY - UPPEREND OF STRINGER INADEQUATELY SUPPORTED WITH VERITCAL 2X6. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
REPAIR AREAWAY WALL | EAST ELEVATION / RETAINING WALL - CRACKED AND MISSING SECTIONS OF CONCRETE. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REAR ONE STORY WOOD PORCH HAS BEEN ENCLOSED AND REMODELED INTO LIVING SPACE. REMOVE ALL PARTITIONS AND FIXTURES (INCLUDING PLUMBING AND ELECTRIC) INSTALLED AT THE REAR PORCH WITHOUT A PERMIT. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
MICE/RODENTS | 1ST FLOOR KITCHEN - EVIDENCE OF RODENTS | 8621 S WALLACE ST | COMPLAINT | FAILED | View |
RESET LOOSE FIXTURE | 2ND FLOOR BATHROOM - LOOSE SINK FIXTURE SUPPORTED WITH TWO VERTICAL 2X2'S. | 8621 S WALLACE ST | COMPLAINT | FAILED | View |