The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING /1ST. FL., 2ND. FL. AND ATTIC APT. - NO RESPONSE; UNABLE TO VERIFY DETECTORS, AND CONDITIONS;UNABLE TO INSPECT [FRONT] INTERIOR STAIRWAY; NOTE: FRONT ELEVATION /ATTIC WINDOW - AIR CONDITIONER WINDOW UNIT INSTALLED, DURING INSPECTION. | 3536 W WOLFRAM ST | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; | 3536 W WOLFRAM ST | COMPLAINT | PASSED | View |
REPAIR PORCH SYSTEM | PLANS AND PERMIT REQUIRED.FRONT 1 STORY WOOD PORCH WITH ROOF.FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE STONE, WITH NO BASES; FOUNDATION STATUS UNKNOWN; FOUNDATIONS /COLUMNS ERECTED ON SOIL, WITH NO BASES; FOUNDATION STATUS UNKNOWN; LEDGER BEAMS /ATTACHED TO BUILDING EXTERIOR WALLS, WITH NAILS ONLY; DECK JOISTS /UNDERSIZED 2X6 DECK JOISTS SPAN 11 FEET, SPACED UP TO 22 INCHES O.C. (APART);STRINGERS /UPPER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; CENTER STRINGER [2X10] - OVERCUT. RAILINGS /METAL GUARD RAILING SECTIONS ONLY 30 INCHES HIGH, WITH PICKETS SPACED UP TO 5 INCHES APART. METAL STAIR RAILING SECTIONS ONLY 30 INCHES HIGH, WITH PICKETS SPACED UP TO 5 INCHES APART - LOOSE AND PULLING, DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING;PLANS AND PERMIT REAR 3 STORY ENCLOSED WOOD PORCH.GRADE TO BASEMENT /HAND RAIL - MISSING. | 3536 W WOLFRAM ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | REAR 3 STORY WOOD ENCLOSED PORCH /SMOKE DETECTOR - MISSING. | 3536 W WOLFRAM ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | REAR 3 STORY WOOD ENCLOSED PORCH /CARBON MONOXIDE DETECTOR - MISSING.NOTE: 1ST. AND 2ND. FL. - FURNACES INSTALLED. | 3536 W WOLFRAM ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE BASEMENT WITHOUT PERMIT. | 3536 W WOLFRAM ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES; | 3536 W WOLFRAM ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO REAR ENCLOSED PORCH /1ST. AND 2ND. FL. - FURNACES INSTALLED OR RESTORE BUILDING TO THE ORIGINAL STATE. SUBJECT TO FIELD INSPECTION AND APPROVAL BY ALL RELATED TRADES; | 3536 W WOLFRAM ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE REAR ENCLOSED PORCH /1ST. AND 2ND. FL. - FURNACES INSTALLED WITHOUT PERMIT. | 3536 W WOLFRAM ST | COMPLAINT | PASSED | View |
OPEN | 3536 W WOLFRAM ST | PERMIT | FAILED | View | |
ARRANGE COMPLETED PERMIT INSP. | 3536 W WOLFRAM ST | PERMIT | PASSED | View |