Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE COMPLETED PERMIT INSP. | 2452 W POLK ST | PERMIT | FAILED | View | |
POST OWNER/MANAGERS NAME/# | POST BUILDING MANAGEMENT IDENTIFICATION AT EXTERIOR | 2452 W POLK ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | REPAIR EXTERIOR WALLS AT: (1)STEP CRACKS BETWEEN FIRST AND SECOND FLOORS AT SOUTH ELEVATION (2)WASHED OUT MORTAR JOINTS AT NORTH ELEVATION NEAR ROOF LEVEL AT NORTH WEST CORNER | 2452 W POLK ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REPLACE MISSING BALUSTERS AT FRONT EXTERIOR STAIR SYSTEM | 2452 W POLK ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REPAIR REAR EXTERIOR PORCH SYSTEM (1)BALUSTRADE HEIGHTS OF 37 INCHES ON FIRST AND SECOND LEVEL DECKS LESS THAN MINIMUM HEIGHT REQUIREMENTS OF 42 INCHES (2) WIDTH OF STAIR SYSTEMS AT 34 AND 35 INCHES IS LESS THAN MINIMUM REQUIREMENT OF 36 INCHES | 2452 W POLK ST | COMPLAINT | FAILED | View |
EXIT THROUGH BEDROOM/BATHROOM | IN FIRST FLOOR APARTMENT ACCESS TO REAR EXIT DOOR IS THROUGH A BEDROOM WHICH IS NOT PERMITTED | 2452 W POLK ST | COMPLAINT | FAILED | View |
SAFE WORKING CONDITIONS | IN GROUND LEVEL APARTMENT OCCUPANT USING KITCHEN STOVE TO HEAT APARTMENT | 2452 W POLK ST | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | ARRANGE INSPECTION WITH APPROVED PLANS TO REVIEW ALTERATIONS COMPLETED UNDER PERMIT B20115142. THERE IS NOT RECORD OF ROUGH OR FINAL INSPECTIONS FOR THE EXTENSIVE RENOVATION | 2452 W POLK ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | PROVIDE LIGHTS WITH WEATHER PROOF BOXES, FITTING AND APPROVE RACEWAYS FOR REAR PORCH AREAS | 2452 W POLK ST | COMPLAINT | FAILED | View |
PROVIDE PUBLIC METER AND PANEL FOR SEPARATE LIVING SPACE, COMMON AREAS, BASEMENT AREAS AND GARAGE- 18-27-210.25 | 2452 W POLK ST | COMPLAINT | FAILED | View | |
PROVIDE ROUGH INSPECTION FOR INSTALLATION OF ELECTRICAL CONDUIT, BOXES, FITTINGS, AND ELECTRICAL EQUIPMENT INSTALLED THROUGH OUT FLOORS 1,2,3 13-12-380 | 2452 W POLK ST | COMPLAINT | FAILED | View | |
GROUND EQUIPMENT | PROPERLY BOND ALL ELECTRICAL PANELS, SERVICE DISCONNECT, AND WATER MAIN GROUND TO WITHIN 5' OF WATER METER OR VALVE | 2452 W POLK ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | IN FIRST FLOOR APARTMENT REAR BEDROOM A BED OBSTRUCTS THE OPENING AND CLOSING OF THE REAR EXIT DOOR | 2452 W POLK ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATION 13-12-360 | 2452 W POLK ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT ELEVATION 1-STORY WOOD PORCH. GUARD RAILS ONLY 37". TREADS ROTTED AND CRACKED. | 2452 W POLK ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION/ EXTERIOR MASONRY WALL - SPALLING, MISSING BRICKS WITH STEP FRACTURES AND WASHED OUT MORTAR. | 2452 W POLK ST | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | FRONT AND WEST ELEVATIONS/ STONE SILLS - CRACKED AND SPALLING. | 2452 W POLK ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITIONS. COULD NOT VERIFY COMPLAINT OF ROACHES, MICE AND MOLD. | 2452 W POLK ST | COMPLAINT | FAILED | View |
REPAIR CORNICE | SCRAPE AND PAINT CORRODED METAL CORNICE AT SOUTH ELEVATION | 2452 W POLK ST | COMPLAINT | FAILED | View |