Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR KITCHEN COUNTERTOP, BATHROOMS, UNFINISHED BASEMENT, EXTERIOR, AND GARAGE PURSUANT TO SECTION 18-27-530.73 OF THE CODE | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE FAUCET | REPAIR THE DEFECTIVE FAUCET AT THE LAUNDRY SINK | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
SEAL DRAIN OPENING UNUSD FIXTR | SEAL THE OPEN 1.5 INCH WASTE PIPE IN THE BASEMENT | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIORS OF BUILDING REFUSED ENTRY, UNVERIFIED DETECTORS | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | FENCE REPAIR- REAR FENCE WOODEN SECTION DAMAGED. -SOUTH FENCE- LEANING | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | EXTERIOR STAIRSYSTEM STRINGER ROTTED, ENTIRE STAIRSYSTEM PITCHED FORWARD. NO PERMIT REQUIRED FOR REPAIRS | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
PRV DISCHARGE PIPE FROM PRV | AT THE WATER HEATER IN THE BASEMENT | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | METER SOCKET ASSEMBLY IS CORRODED | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
PRV CLEANOUT AT BASE OF STACK | INSTALL CLEAN-OUT AT THE 4 INCH STACK IN THE BASEMENT | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
ADD RECEPTACLES | IN THE BASEMENT AREA USED AS BEDROOMS - CURRENTLY INADEQUATE RECEPTACLES FOR WALL SPACES - AND PROVIDE RECEPTACLE IN GARAGE | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
PROPER SIZE GRD ELECTRODE COND | THE EXISTING GROUNDING CONDUCTOR IS UNDERSIZED | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | 4427 N MELVINA AVE | COMPLAINT | FAILED | View | |
EXPOSED WIRING | IN THE BASEMENT NEXT TO THE ELECTRICAL PANEL - A DANGEROUS AND HAZARDOUS CONDITION | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PROVIDE APPROVED PLANS AND PERMITS FOR THE REMOVAL OF THE REAR EXTERIOR WALL, WHICH INCORPORATED PORCH SYSTEM INTO DWELLING UNIT | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | THE GARAGE EXTERIOR WALLS ARE MISSING DOUBLE TOP PLATE, THE SOUTHWEST ELEVATION OF SOUTH WALL IS SINKING, THE 2X6 ROOF JOISTS ARE OVERSPANNED, THE 2X6 RIDGE IS UNDERSIZED - PLANS AND PERMITS ARE REQUIRED FOR REPAIRS | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE PVC FLEXIBLE WATER LINES TO FIXTURES ON THE FIRST FLOOR AND BASEMENT | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
SUPPORT FIXTURES | IN THE BASEMENT | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
INSTALL TRAP,WASTE,VENT PIPES | INSTALL VENT FOR THE KITCHEN SINK; FOR THE TUB-SHOWER ON THE FIRST FLOOR; AND INSTALL VENT PIPES FOR TOILET, LAVATORY, AND SHOWER IN THE BASEMENT | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
ARMORED CABLE | REMOVE ALL EXPOSED RUNS FROM THE KITCHEN CEILING AND BASEMENT | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WATER PIPING | INSTALL PROPER MATERIAL BETWEEN COPPER AND GALVANIZED PIPING IN THE BASEMENT | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
SOIL/WASTE,VENT PIPE MATRL | REMOVE WATER PIPE FITTINGS INSTALLED ON KITCHEN SINK WASTE PIPE AND INSTALL PROPER FITTINGS | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
LICENSED BONDED PLMBG CONTRCTR | 4427 N MELVINA AVE | COMPLAINT | FAILED | View | |
SUBMIT STRUCT. ENG. RPT (INT.) | PROVIDE A STRUCTURAL ENGINEER'S REPORT FOR STABILITY OF STRUCTURE FOLLOWING REMOVAL OF THE REAR EXTERIOR WALL | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
DEFECTIVE LIGHTING SERVICE | THE SE TYPE SERVICE RISER IS SEVERELY DETERIORATED AND MUST BE REPLACED | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | PROVIDE APPROVED PLANS AND PERMITS FOR THE ERECTION OF A TWO AND A HALF CAR GARAGE | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | PROVIDE LIGHTS AT ALL EXTERIOR DOORS AND GARAGE | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | IN THE BASEMENT AND ON THE FIRST FLOOR, ALL THE NON-WORKING LIGHTS AND THOSE MISSING GLOVES AND COVERS | 4427 N MELVINA AVE | COMPLAINT | FAILED | View |