Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-24 @ 6:55 PM
PIN: 20082030280000
Property Address: 1048 W 48TH ST
City - Zip: CHICAGO - 60609
2023 Property Class: 202
2023 Township: 72 - Lake
2023 Neighborhood: 72051
2023 Tax District: 72103
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 17 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION OWNER REFUSED ENTRY; UNABLE TO VERIFY DETECTORS, CONDITIONS, AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRS. UNABLE TO INSPECT COMPLAINT - MULTIPLE FAMILIES LIVING IN A SINGLE FAMILY HOME; 1048 W 48TH ST COMPLAINT FAILED View
OBTAIN OR POST PERMIT 1048 W 48TH ST COMPLAINT CLOSED View
MAINTAN BLDG IN SAFE CONDITION 1048 W 48TH ST COMPLAINT CLOSED View
REPAIR/WRECK DANGER RESID PREM 1048 W 48TH ST COMPLAINT CLOSED View
WATCHMAN 1048 W 48TH ST COMPLAINT CLOSED View
VACANT BUILDING - REGISTER 1048 W 48TH ST COMPLAINT CLOSED View
POST OWNER INFO ON ABDN BLDG 1048 W 48TH ST COMPLAINT CLOSED View
BLANK-TEXT MUST CITE CODE SECT STOP ALL WORK ON PREMISES UNTIL APPROVED PLANS AND BUILDING PERMIT ARE OBTAINED 13-12-080 13-32-035 1048 W 48TH ST COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR INTERIOR ALTERATIONS REMOVED EXISTING INTERIOR PARTITIONS ERECTED NEW INTERIOR PARTITIONS 1048 W 48TH ST COMPLAINT FAILED View
REPLACE D&H PORCH FRONT 1 STORY DANGEROUS & HAZARDOUS WOOD PORCH, WITH METAL GUARD AND STAIR RAILING SECTIONS;FOUNDATION /COLUMNS ERECTED ON TOP OF CONCRETE AND WOOD BLOCKS, WITH NO BASES; FOUNDATION STATUS UNKNOWN;LEDGER BEAM /ROTTING, ATTACHED TO BUILDING EXTERIOR WALL, WITH NAILS ONLY;DECK JOISTS /ROTTING, FASTENED TO LEDGER BEAM AND HEADER JOIST, WITH NAILS ONLY;STRINGERS /ROTTING, LOOSE, UPPER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER, FASTENED WITH NAILS ONLY; STAIRS /TREADS - ROTTING, LOOSE, WORN OUT, CRACKED, WEAK; RISER HEIGHT NOT UNIFORMED, RANGE FROM 4 1/2 INCHES TO 6 INCHES;DECKING /DECK BOARDS - ROTTINGM, DAMAGED, BUCKLED UP;RAILINGS /METAL GUARD AND STAIR RAILING SECTIONS - LOOSE AND PULLING; METAL GUARD RAILING SECTIONS - ONLY 32 INCHES HIGH;PLANS AND PERMIT REQUIRED TO REPLACE 1 STORY DANGEROUS AND HAZARDOUS WOOD PORCH, WITH METAL GUARD AND STAIR RAILING SECTIONS; 1048 W 48TH ST COMPLAINT PASSED View
REPAIR PORCH SYSTEM REAR 1 STORY ENCLOSED WOOD PORCH;FOUNDATION /[ENTRY RERFUSED] UNABLE TO INSPECT FOOTINGS; FOUNDATION STATUS UNKNOWN;COLUMNS /[ENTRY RERFUSED] UNABLE TO INSPECT;LEDGER BEAM /[ENTRY RERFUSED] UNABLE TO INSPECT;BEAMS /[ENTRY RERFUSED] UNABLE TO INSPECT;DECK JOISTS /[ENTRY RERFUSED] UNABLE TO INSPECT;STRINGERS /UPPER ENDS OF STRINGERS INADEQUATE SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; LOWER ENDS OF STRINGERS INADEQUATE SUPPORTED AT COLUMNS, FASTENED WITH NAILS /SCREWS ONLY;STAIRS /TREADS - ROTTING; RISER HEIGHT NOT UNIFORMED, RANGING FROM 4 1/2 INCHES TO 11 INCHES;DECKING /[ENTRY RERFUSED] UNABLE TO INSPECT;RAILINGS /STAIR RAILING SECTIONS - LOOSE AND PULLING, ARE OF LADDER TYPE DESIGN; WITH ANGLE TIES SPACED UP TO 124 INCHES APART;PERMIT ONLY REQUIRED TO REPLACE STAIR SYSTEM; 1048 W 48TH ST COMPLAINT PASSED View
PROVIDE GUTTER & DOWNSPOUT REAR ELEVATION /LOWER ROOF -MISSING GUTTERS AND DOWNSPOUT; 1048 W 48TH ST COMPLAINT PASSED View
REPAIR EAVES REAR ELEVATION /EAVES, FASCIA AND SOFFIT - ROTTING, BROKEN AND MISSING BOARDS; 1048 W 48TH ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID BASEMENT - NO CARBON MONOXIDE DETECTOR . FIRST FLOOR CARBON MONOXIDE DETECTOR OUT OF SERVICE DATE . 1048 W 48TH ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTOR - TOP OF ATTIC STAIRS . 1048 W 48TH ST COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION OWNER REFUSED ENTRY; UNABLE TO VERIFY DETECTORS, CONDITIONS, AND OCCUPANCY. UNABLE TO INSPECT INTERIOR STAIRS. UNABLE TO INSPECT COMPLAINT - MULTIPLE FAMILIES LIVING IN A SINGLE FAMILY HOME; 1048 W 48TH ST COMPLAINT PASSED View
REPAIR INTERIOR STAIR SYSTEM STAIRWAY TO ATTIC INSTALLED WITHOUT PLANS OR PERMITS . UNDERSIZED WITH HEADROOM OF ONLY 55 INCHES . REMOVE ALL WORK INSTALLED WITHOUT A PERMIT . 1048 W 48TH ST COMPLAINT PASSED View